Distribution Fault Location Using Wide-Area Voltage Magnitude Measurements

被引:0
|
作者
Hossain, Shamina [1 ]
Zhu, Hao [1 ]
Overbye, Thomas [1 ]
机构
[1] Univ Illinois, Urbana, IL 61801 USA
关键词
fault location; voltage monitoring; WAMS; distribution system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In an effort to increase situational awareness in the electric power grid, Wide-Area Measurement Systems (WAMS) are being implemented. These systems allow the capture of fast-sampled voltage data such as frequency, voltage magnitude, and voltage angle measurements in a low-cost, easily deployable manner. Traditional fault location methods use both current and voltage data. Voltage monitoring devices only collect voltage data, but these sensors can collect this data anywhere along the distribution lines. An iterative simulation-based fault location method using only voltage measurements, from anywhere on the line, is proposed. This technique involves comparing a measured voltage profile of a specific fault type and phase with a calculated voltage profile obtained through simulation of such a fault occurring at various locations with a range of probable fault impedances in the system. The best match is determined using the Euclidean error norm criterion and a threshold error value. The algorithm is successfully demonstrated using a PowerWorld case study.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Fault Location using PMU Measurements and Wide-area Infrastructure
    Picard, Stephan D.
    Adamiak, Mark G.
    Madani, Vahid
    [J]. 2015 68TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2015, : 272 - 277
  • [2] Fault Location Using Wide-Area Measurements and Sparse Estimation
    Feng, Guangyu
    Abur, Ali
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (04) : 2938 - 2945
  • [3] Fault Location Method Based on Wide-Area Voltage
    Xu, Yan
    Ying, Lu-man
    Zhi, Jing
    Feng, Ren-qing
    [J]. ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 2077 - +
  • [4] Wide-Area Fault Location of Transmission Lines by Hybrid Synchronized/Unsynchronized Voltage Measurements
    Dobakhshari, Ahmad Salehi
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (03) : 1869 - 1877
  • [5] Distribution High Impedance Fault Location Using Localized Voltage Magnitude Measurements
    Hossain, Shamina
    Zhu, Hao
    Overbye, Thomas
    [J]. 2014 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2014,
  • [6] Application of synchronised phasor measurements to wide-area fault diagnosis and location
    Salehi-Dobakhshari, Ahmad
    Ranjbar, Ali Mohammad
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (04) : 716 - 729
  • [7] Application of synchronised phasor measurements to wide-area fault diagnosis and location
    Salehi-Dobakhshari, Ahmad
    Ranjbar, Ali Mohammad
    [J]. IET Generation, Transmission and Distribution, 2014, 8 (04): : 716 - 729
  • [8] A Novel Method for Fault Location of Transmission Lines by Wide-Area Voltage Measurements Considering Measurement Errors
    Dobakhshari, A. Salehi
    Ranjbar, A. M.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (02) : 874 - 884
  • [9] Accurate Fault Location for Untransposed/Transposed Transmission Lines Using Sparse Wide-Area Measurements
    Jiao, Xiangqing
    Liao, Yuan
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) : 1797 - 1805
  • [10] Optimal Deployment of Wide-Area Synchronized Measurements for Fault-Location Observability
    Korkali, Mert
    Abur, Ali
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (01) : 482 - 489