IMPROVING THE THERMAL PERFORMANCE OF A FORCED CONVECTION AIR COOLED SOLUTION - PART 2: EFFECT ON SYSTEM-LEVEL PERFORMANCE

被引:0
|
作者
Fernandes, John Edward [1 ]
Ghalambor, Saeed [1 ]
Eiland, Richard [1 ]
Agonafer, Dereje [1 ]
Mulay, Veerendra [2 ]
机构
[1] Univ Texas Arlington, Arlington, TX 76019 USA
[2] Facebook Inc, Menlo Pk, CA USA
关键词
Server; back plate; interfacial pressure; TIM performance; power consumption;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat sink assembly of an air cooled CPU is modified to improve thermal performance of the module-level solution.. This modification is employed in a dual-socket server that relies on system fans to move air for forced convection cooling of all heat generating components on the motherboard. Currently, in the data center industry, the focus is on reducing power consumption through application of energy-efficient cooling solutions. Fans installed in the server operate as a function of CPU die temperatures and represent a parasitic load that must be minimized. Improvement in system-level performance can be quantified in terms of reduced fan and server power consumption. The server is subjected to varying CPU utilizations and corresponding average fan speeds and power consumption are reported. Similarly, reduction in CPU junction temperature and server power at a given utilization can be computed by operating the fans at a constant speed. Difference in thermal performance and power consumption between the baseline and modified heat sink configurations was found to negligible when a TIM is applied. However, in the absence of a TIM, the modified assembly delivered as much as 24.4% reduction in CPU die temperature and 6.2% reduction in server power consumption. In addition, there is indiscernible variation in server power consumption between the baseline (with employment of TIM) and modified (with and without TIM application) heat sink assemblies. Thus, the modified configuration has possible applications in systems where a TIM may be undesirable or difficult to apply.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] IMPROVING THE THERMAL PERFORMANCE OF A FORCED CONVECTION AIR COOLED SOLUTION - PART 1: MODIFICATION OF HEAT SINK ASSEMBLY
    Ghalambor, Saeed
    Fernandes, John Edward
    Agonafer, Dereje
    Mulay, Veerendra
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2013, VOL 2, 2014,
  • [2] Performance measurements of a forced convection air-cooled rack
    Hwang, Y
    Radermacher, R
    Spinazzola, S
    Menachery, Z
    ITHERM 2004, VOL 1, 2004, : 194 - 198
  • [3] Thermal performance of an air-cooled plastic ball grid array package in natural and forced convection
    Ramakrishna, K
    Thomas, TR
    Lee, TYT
    Trent, JR
    Hause, JV
    ITHERM '98: SIXTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 1998, : 27 - 34
  • [4] Improving System-level performance and robustness in power line monitoring
    Gil, Lluis Beltran
    Electronics World, 2024, 129 (2041): : 22 - 24
  • [5] IMPROVING PERFORMANCE OF FORCED - AIR HEATING SYSTEM IN BROILER HOUSE
    Ghoname, Mohamed
    Fouda, Tarek
    SCIENTIFIC PAPERS-SERIES MANAGEMENT ECONOMIC ENGINEERING IN AGRICULTURE AND RURAL DEVELOPMENT, 2015, 15 (04) : 77 - 84
  • [6] System-Level Performance of an Automation Solution Based on Industry Standards
    Ballarino, Andrea
    Brusaferri, Alessandro
    Cereia, Marco
    Bertolotti, Ivan Cibrario
    Durante, Luca
    Hu, Tingting
    Leo, Egidio
    Nicolosi, Leonardo
    Seno, Lucia
    Spinelli, Stefano
    Tramarin, Federico
    Valenzano, Adriano
    Vitturi, Stefano
    2014 IEEE EMERGING TECHNOLOGY AND FACTORY AUTOMATION (ETFA), 2014,
  • [7] Material And Height Effects On The Heat Transfer Performance Of Metal Foams Cooled By Air In Forced Convection
    Mancin, Simone
    Zilio, Claudio
    Diani, Andrea
    Rossetto, Luisa
    POROUS MEDIA AND ITS APPLICATIONS IN SCIENCE, ENGINEERING, AND INDUSTRY, 2012, 1453 : 231 - 236
  • [8] Improving the thermal-hydraulic performance of air-cooled battery thermal management system by flow splitters
    Gao, Chen
    Song, Kewei
    He, Rong
    Qi, Yue
    Gu, Bingdong
    Su, Mei
    An, Zhoujian
    JOURNAL OF ENERGY STORAGE, 2024, 101
  • [9] Effects of forced convection on the performance of a photovoltaic thermal system: An experimental study
    Kasaeian, Alibakhsh
    Khanjari, Yasamin
    Golzari, Soudabeh
    Mahian, Omid
    Wongwises, Somchai
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 85 : 13 - 21
  • [10] Thermal performance metrics for arranging forced air cooled servers in a data processing cabinet
    Rambo, J