Vacuum for straightening the microcatheter after intra-aneurysmal looping: The "Lagman vacuum" technique

被引:0
|
作者
Lagios, Konstantinos [1 ]
Mantatzis, Michalis [2 ]
机构
[1] 251 Air Force Hosp, Intervent Radiol & Neuroradiol Dept, Athens, Greece
[2] Democritus Univ Thrace, Univ Hosp Alexandroupolis, Radiol Dept, Katakouzinou 56, Dragana 68100, Alexandroupolis, Greece
关键词
Intracranial aneurysm; therapeutic embolization; endovascular procedures; stents; BALLOON;
D O I
10.1177/1591019918824867
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In many cases, an intra-arterial microcatheter loop is necessary to bypass the neck of wide-necked giant aneurysms for the placement of a stent across it. The removal of this loop is usually challenging, and many techniques have been described to achieve it. We describe a simple novel technique for straightening the microcatheter across the aneurysm's neck, without the need for additional products/devices or complex exchanging techniques. The method has been successfully applied in two cases. We named this novel maneuver the "Lagman vacuum" technique.
引用
收藏
页码:438 / 441
页数:4
相关论文
共 48 条
  • [1] Intra-aneurysmal microcatheter looping technique for stent-assisted embolization of complex intracranial aneurysms
    Wang, C-C
    Lv, N.
    Feng, Z-Z
    Li, Z-F
    Zhao, R.
    Li, Q.
    Liu, J-M
    Huang, Q-H
    INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (05) : 580 - 584
  • [2] Intra-aneurysmal pressure after incomplete endovascular exclusion
    Parodi, JC
    Berguer, R
    Ferreira, LM
    La Mura, R
    Schermerhorn, ML
    JOURNAL OF VASCULAR SURGERY, 2001, 34 (05) : 909 - 914
  • [3] Intra-aneurysmal thrombus modification after flow-diversion
    Zanaty, Mario
    Jabbour, Pascal M.
    Sader, Roula Bou
    Chalouhi, Nohra
    Tjoumakaris, Stavropoula
    Rosenwasser, Robert H.
    Gonzalez, L. Fernando
    JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (01) : 105 - 110
  • [4] Multiple intra-aneurysmal WEB devices: Case discussions and operative technique
    Hudson, Joseph S.
    Zanaty, Mario
    Roa, Jorge A.
    Jabbour, Pascal
    Samaniego, Edgar A.
    Hasan, David M.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 80 : 108 - 111
  • [5] Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment
    Kulcsar, Z.
    Houdart, E.
    Bonafe, A.
    Parker, G.
    Millar, J.
    Goddard, A. J. P.
    Renowden, S.
    Gal, G.
    Turowski, B.
    Mitchell, K.
    Gray, F.
    Rodriguez, M.
    van den Berg, R.
    Gruber, A.
    Desal, H.
    Wanke, I.
    Ruefenacht, D. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 20 - 25
  • [6] Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage
    Froelich, Andreas Maximilian
    Nawka, Marie Teresa
    Ernst, Marielle
    Frischmuth, Isabell
    Fiehler, Jens
    Buhk, Jan-Hendrik
    PLOS ONE, 2018, 13 (02):
  • [7] The "pipe-anchor" technique: A method for intra-aneurysmal loop reduction using a partially unsheathed pipeline stent
    Doron, Omer
    Vranic, Justin
    Regenhardt, Robert
    Stapleton, Christopher
    Patel, Aman
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [8] Intra-aneurysmal air after flow diversion treatment in intracranial aneurysms: incidence, characteristics and clinical significance
    Osman Ocal
    Anıl Arat
    Japanese Journal of Radiology, 2019, 37 : 549 - 554
  • [9] Evaluation of intra-aneurysmal hemodynamics after flow diverter placement in a patient-specific aneurysm model
    Balasso, Andrea
    Bauer, Jan S.
    Liebig, Thomas
    Dorn, Franziska
    Zimmer, Claus
    Liepsch, Dieter
    Prothmann, Sascha
    BIORHEOLOGY, 2014, 51 (06) : 341 - 354
  • [10] Intra-aneurysmal air after flow diversion treatment in intracranial aneurysms: incidence, characteristics and clinical significance
    Ocal, Osman
    Arat, Anil
    JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (07) : 549 - 554