Assessment of skin microcirculation by laser Doppler flowmetry in systemic sclerosis patients

被引:19
|
作者
Waszczykowska, Arleta [1 ]
Gos, Roman [2 ]
Waszczykowska, Elzbieta [3 ]
Dziankowska-Bartkowiak, Bozena [3 ]
Jurowski, Piotr [1 ]
机构
[1] Med Univ Lodz, Inst Eye Dis Diagnost, Dept Eye Dis 2, PL-90549 Lodz, Poland
[2] Med Univ Lodz, Inst Ophthalmol & Vis Rehabil, Dept Eye Dis 2, PL-90549 Lodz, Poland
[3] Med Univ Lodz, Dept Dermatol & Venereal Dis, PL-90549 Lodz, Poland
来源
POSTEPY DERMATOLOGII I ALERGOLOGII | 2014年 / 31卷 / 01期
关键词
sclerosis; scleroderma; microangiopathy; laser Doppler flowmeter; BLOOD-FLOW; RAYNAUDS-PHENOMENON; DISEASE;
D O I
10.5114/pdia.2014.40653
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Introduction: First lesions to occur in the course of systemic sclerosis(SSc) involve microcirculation. Aim: The study involved assessment of the suitability of laser Doppler flowmetry(LDF) in examination of the performance of skin microcirculation in the distal portion of the upper extremity in SSc patients. Material and methods: Overall the study involved 27 patients with systemic sclerosis. The control group comprised age and gender-matched 27 healthy individuals. All the study subjects underwent microcirculation perfusion measurement at rest (rest flow-RF) as well as microcirculatory flow challenge tests reactive hyperaemia test (RHT) and thermal stimulation test (TST). Results: The study did not show any differences in the skin microcirculation perfusion at rest between the test group and the control, while reactive hyperaemia test results revealed significantly lower skin microcirculation perfusion values during the cuff inflation in SSc patients, as compared to the controls. In the test group, a lower perfusion value was observed during secondary hyperaemia following cuff release. Comparative analysis of skin microcirculation perfusion changes during the thermal stimulation test revealed a significantly lower change of the perfusion value and longer time of return to the baseline in the test group as compared to the control group. Conclusions: The study performed has shown the suitability of LDF in the assessment of the microangiopathy degree in systemic sclerosis patients. The skin perfusion value in SSc patients should be assessed on the basis of parameters obtained in microcirculation challenge tests.
引用
收藏
页码:6 / 11
页数:6
相关论文
共 50 条
  • [1] Assessment of cutaneous microcirculation in unaffected skin regions by transcutaneous oxygen saturation monitoring and Laser Doppler flowmetry in systemic sclerosis
    Broz, Pavel
    Aschwanden, Markus
    Partovi, Sasan
    Schulte, Anja-Carina
    Benz, Daniela
    Takes, Martin
    Walker, Ulrich A.
    Bilecen, Deniz
    Jaeger, Kurt A.
    Imfeld, Stephan
    Staub, Daniel
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2015, 60 (03) : 263 - 271
  • [2] ASSESSMENT OF THE NAILFOLD SKIN MICROCIRCULATION BY HIGH-FREQUENCY ULTRASOUND DOPPLER FLOWMETRY: A COMPARISON TO LASER DOPPLER FLOWMETRY
    Lenasi, H.
    Potocnik, N.
    Egorkina, A.
    Papp, M.
    Girina, M.
    [J]. JOURNAL OF VASCULAR RESEARCH, 2015, 52 : 42 - 42
  • [3] LASER DOPPLER FLOWMETRY FOR THE ASSESSMENT OF THE CEREBRAL MICROCIRCULATION
    ELLIS, EF
    HEIZER, ML
    ZHANG, X
    MARMAROU, A
    HABERL, R
    [J]. FASEB JOURNAL, 1988, 2 (04): : A507 - A507
  • [4] Laser Doppler imaging for assessment of microcirculation in juvenile systemic sclerosis
    Petry Piotto, Daniela Gerent
    Uchoa Correa, Marcelo Jose
    Miotto e Silva, Vanessa Bugni
    Kayser, Cristiane
    Terreri, Maria Teresa R. A.
    [J]. RHEUMATOLOGY, 2014, 53 (01) : 72 - 75
  • [5] Laser Doppler flowmetry in the study of feet skin microcirculation in IDDM
    Taton, J
    Czech, A
    Buraczewska, B
    [J]. DIABETOLOGIA, 1999, 42 : A306 - A306
  • [6] MICROCIRCULATION IN THE BOVINE TEAT SKIN, MEASURED BY LASER DOPPLER FLOWMETRY
    PERSSON, K
    [J]. ACTA VETERINARIA SCANDINAVICA, 1991, 32 (01) : 131 - 133
  • [7] SYNCHRONOUS ASSESSMENT OF HUMAN-SKIN MICROCIRCULATION BY LASER DOPPLER FLOWMETRY AND DYNAMIC CAPILLAROSCOPY
    TOOKE, JE
    OSTERGREN, J
    FAGRELL, B
    [J]. INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1983, 2 (04): : 277 - 284
  • [8] THE EFFECT OF PRAZOSIN ON SKIN MICROCIRCULATION AS ASSESSED BY LASER DOPPLER FLOWMETRY
    KHAN, F
    STRUTHERS, AD
    SPENCE, VA
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1988, 26 (03) : 267 - 272
  • [9] VASOMOTOR ACTIVITY SKIN MICROCIRCULATION AS ASSESSED BY LASER DOPPLER FLOWMETRY IN PATIENTS WITH MICROVASCULAR ANGINA
    Soboleva, G.
    Karpova, I.
    Fedorovich, A.
    Rogoza, A.
    [J]. JOURNAL OF VASCULAR RESEARCH, 2015, 52 : 14 - 14
  • [10] Monitoring tumor progression by mapping skin microcirculation with laser Doppler flowmetry
    Pedanekar, Tanvi
    Kedare, Rohit
    Sengupta, Amit
    [J]. LASERS IN MEDICAL SCIENCE, 2019, 34 (01) : 61 - 77