Registration and summation of RG/BH PET images based on estimation of deformation of lung from CT images

被引:0
|
作者
Kanai, Masayuki [1 ]
Tamai, Yoshitaka [2 ]
Sakohira, Atsushi [2 ]
Suga, Kazuyoshi [2 ]
Haneishi, Hideaki [3 ]
机构
[1] Chiba Univ, Dept Med Syst Engn, Grad Sch Engn, Chiba, Japan
[2] St Hill Hosp, Yamaguchi, Japan
[3] Chiba Univ, Res Ctr Frontier Med Engn, Chiba, Japan
关键词
MOTION CORRECTION; ARTIFACTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lung motion due to respiration causes image degradation in medical imaging, especially in nuclear medicine which requires long acquisition time. We have developed a method for image correction between the respiration-gated (RG) PET images in different respiration phases or breath-hold (BH) PET images in inconsistent respiration phase. In the method, the RG or BH PET images in different respiration phase are deformed under two criteria; similarity of image density distribution and smoothness of estimated motion vector field (MVF). However, only these criteria may cause un-natural motion estimation of lung. In this paper, assuming the use of a PET-CT scanner, we add another criterion that is the similarity to the motion direction estimated from inhalation and exhalation CT images. The proposed method was applied to XCAT phantom image data and seven patients' BH-PET image data. Successful registration results were obtained by the proposed method.
引用
收藏
页码:2981 / 2985
页数:5
相关论文
共 50 条
  • [1] Registration and Summation of Respiratory-Gated or Breath-Hold PET Images Based on Deformation Estimation of Lung from CT Image
    Haneishi, Hideaki
    Kanai, Masayuki
    Tamai, Yoshitaka
    Sakohira, Atsushi
    Suga, Kazuyoshi
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [2] Registration and Fusion of Lung Tumor PET/CT Images
    Ayyildiz, Oguzhan
    Yilmaz, Bulent
    Karacavus, Seyhan
    Kayaalti, Omer
    Icer, Semra
    Eset, Kubra
    Kaya, Eser
    2015 MEDICAL TECHNOLOGIES NATIONAL CONFERENCE (TIPTEKNO), 2015,
  • [3] Deformation and summation of breath-hold PET images
    Haneishi, Hideaki
    Kobuna, Kyoka
    Kanai, Masayuki
    Tamai, Yoshitaka
    Sakohira, Atsushi
    Suga, Kazuyoshi
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3602 - 3604
  • [4] Estimation of CT images from PET images without nonattenuation-corrected PET images using GAN
    Saito, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S622 - S622
  • [5] Nonrigid Registration of Lung CT Images Based on Tissue Features
    Zhang, Rui
    Zhou, Wu
    Li, Yanjie
    Yu, Shaode
    Xie, Yaoqin
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [6] Elastic registration of prostate MR images based on estimation of deformation states
    Marami, Bahram
    Sirouspour, Shahin
    Ghoul, Suha
    Cepek, Jeremy
    Davidson, Sean R. H.
    Capson, David W.
    Trachtenberg, John
    Fenster, Aaron
    MEDICAL IMAGE ANALYSIS, 2015, 21 (01) : 87 - 103
  • [7] Registration of Lung CT Images Using B-spline Based Free-Form Deformation
    Zhang, Limei
    Li, Min
    Hou, Wensheng
    Fan, Panyun
    PROCEEDINGS OF THE 2018 IEEE INTERNATIONAL CONFERENCE ON PROGRESS IN INFORMATICS AND COMPUTING (PIC), 2018, : 440 - 444
  • [8] 3-DIMENSIONAL REGISTRATION OF PET AND CT IMAGES
    KOVACIC, S
    GEE, JC
    CHING, WSL
    REIVICH, M
    BAJCSY, R
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 548 - 549
  • [9] Algorithm for Lung Cancer Detection Based on PET/CT Images
    Saita, Shinsuke
    Ishimatsu, Keita
    Kubo, Mitsuru
    Kawata, Yoshiki
    Niki, Noboru
    Ohtsuka, Hideki
    Nishitani, Hiromu
    Ohmatsu, Hironobu
    Eguchi, Kenji
    Kaneko, Masahiro
    Moriyama, Noriyuki
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [10] Image Registration for PET/CT and CT images with Particle Swarm Optimization
    Lee, Hakjae
    Lee, Kisung
    Kim, Yongkwon
    Joung, Jinhun
    Moon, Kookhyun
    Joo, Sung-Kwan
    Kim, Kyeong-Min
    Chun, Gi-Jeong
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3717 - +