Analysis of backflow within an external centrifugal blood pump for ventricular assist device

被引:0
|
作者
Rungsirigulnan, Chitsanupong [1 ]
Laohasurayodhin, Ravi [1 ]
Tuanthammaruk, Thisana [1 ]
Chusri, Yanee [1 ]
Diloksumpan, Paweena [1 ]
Naiyanetr, Phornphop [1 ]
机构
[1] Mahidol Univ, Dept Biomed Engn, Fac Engn, Phuttamonthon 73170, Nakhonpathom, Thailand
关键词
RBPs; Backflow; HQ-curve; Mock circulation Introduction (Heading 1);
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During left ventricular support by rotary blood pumps (RBPs), pump speed plays an important role in the amount of heart support. The reducing of pump speed seems important in order to prevent some adverse events in the heart valve. However, when pump speed was reduced, the backflow which is the flow that has the reverse direction to blood pumping direction may occur more easily. This is due to the amount of pressure at an outlet of pump. Head pressure and pump flow curve (HQ-curve) is the graph that shows the performance of speed, head pressure and flow rate in the blood pump. In this study, two impellers from MUAD-VAD02 were used; 90-degree-angle straight blade (90SB) and 130 degrees straight blade (130BSB). The backflow of two impellers were investigated at three pump speeds (1000, 1400 and 1800 rpm) using HQcurve, negative flow rate vs. time, and pressure vs. time. The experimental study uses in vitro testing by simulating the natural circulatory system with RBPs in the mock circulation loop system. The back flow of 90SB had more negative flow than BSB at all three speeds. In conclusion, BSB- impeller was chosen over the 90SB-impeller because at the same head pressure and speed in HQ-curve, the BSB impeller has less negative flow.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] HeartQuest ventricular assist device magnetically levitated centrifugal blood pump
    Bearnson, GB
    Jacobs, GB
    Kirk, J
    Khanwilkar, PS
    Nelson, KE
    Long, JW
    [J]. ARTIFICIAL ORGANS, 2006, 30 (05) : 339 - 346
  • [2] CLINICAL-EXPERIENCE WITH A CENTRIFUGAL PUMP VENTRICULAR ASSIST DEVICE
    PENNINGTON, DG
    MERJAVY, JP
    SWARTZ, MT
    WILLMAN, VL
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 93 - 99
  • [3] Analysis of backflow effect in a centrifugal pump
    Kang, W. Z.
    Zhou, L. J.
    Wang, Z. W.
    Wang, W.
    [J]. 29TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2019, 240
  • [4] Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device
    Yoshikawa, M
    Nakata, K
    Ohtsuka, G
    Takano, T
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 1999, 23 (08) : 774 - 779
  • [5] Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump
    Yoshikawa, M
    Nonaka, K
    Linneweber, J
    Kawahito, S
    Ohtsuka, G
    Nakata, K
    Takano, T
    Schulte-Eistrup, S
    Glueck, J
    Schima, H
    Wolner, E
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 2000, 24 (06) : 459 - 467
  • [6] Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device
    Baylor College of Medicine, Houston, TX, United States
    不详
    不详
    [J]. Artif. Organs, 8 (774-779):
  • [7] Development of a totally implantable pulsatile centrifugal pump as a ventricular assist device
    Chou, NK
    Wang, SS
    Lin, YH
    Shyu, TJ
    Hsieh, KH
    Jan, GJ
    Chu, SH
    [J]. ARTIFICIAL ORGANS, 2001, 25 (08) : 603 - 606
  • [8] Numerical solution for blood flow in a centrifugal ventricular assist device
    Wood, HG
    Anderson, J
    Allaire, PE
    McDaniel, JC
    Bearnson, G
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (12): : 827 - 836
  • [9] In vivo evaluation of the miniaturized Gyro centrifugal pump as an implantable ventricular assist device
    Takami, Y
    Otsuka, G
    Mueller, J
    Sugita, Y
    Nakata, K
    Tayama, E
    Ohashi, Y
    Schima, H
    Schmallegger, H
    Wolner, E
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1998, 22 (08) : 713 - 720
  • [10] Experimental study of dynamic characteristics of a centrifugal blood pump with a conical spiral groove bearing for a ventricular assist device
    Nakamura, Youichi
    Tsukamoto, Hiroshi
    Miyazaki, Koji
    [J]. FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT AMSE/JSME FLUIDS ENGINEERING SUMMER CONFERENCE VOL 1, PTS A AND B, 2007, : 1187 - 1194