Application of Appropriateness Criteria in Outpatient Transthoracic Echocardiography

被引:59
|
作者
Kirkpatrick, James N. [1 ]
Ky, Bonnie [1 ]
Rahmouni, Hind W. [1 ]
Chirinos, Julio A. [1 ]
Farmer, Steven A. [1 ]
Fields, Anjali V. [1 ]
Ogbara, Jeffrey [1 ]
Eberman, Karen M. [1 ]
Ferrari, Victor A. [1 ]
Silvestry, Frank E. [1 ]
Keane, Martin G. [1 ]
Opotowsky, Alexander R. [1 ]
Sutton, Martin St. John [1 ]
Wiegers, Susan E. [1 ]
机构
[1] Univ Penn, Dept Med, Div Cardiovasc, Echocardiog Lab, Philadelphia, PA 19104 USA
关键词
Echocardiography; Appropriateness; Outpatient; LEFT-VENTRICULAR DYSFUNCTION; HEART-FAILURE; PREVALENCE; POPULATION; DIAGNOSIS;
D O I
10.1016/j.echo.2008.10.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Appropriateness criteria were applied to outpatient transthoracic echocardiographic (TTE) studies. Methods: Indications were rated as appropriate, inappropriate, or unclassifiable, considering provider-stated indications, previous TTE studies, symptom changes, and patient-stated indications. Clinically important new or unexpected findings were recorded. Results: Of 368 TTE studies, 206 (56%) were appropriate, 31 (8%) were inappropriate, and 131 (35%) were unclassifiable. Appropriateness was not correlated with patient or provider demographics. In 288 cases with prior TTE studies, there were 92 (32%) important new findings and 63 (22%) unexpected findings, of which 20% were from inappropriately ordered and 31% from unclassifiable TTE studies. Appropriateness was not associated with new (odds ratio, 1.23; 95% confidence interval, 0.48-3.18) or unexpected (odds ratio, 1.15; 95% confidence interval, 0.38-3.52) findings. Provider type and level of training were not correlated with new or unexpected findings. Conclusions: Many indications for TTE studies were unclassifiable. A high percentage of inappropriately ordered TTE studies yielded important information. Care must be taken in judging the value of TTE studies solely on the basis of appropriateness criteria. (J Am Soc Echocardiogr 2009; 22: 53-59.)
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [1] Trends in Outpatient Transthoracic Echocardiography: Impact of Appropriateness Criteria Publication
    Rahimi, Ali R.
    York, Meghan
    Gheewala, Neil
    Markson, Larry
    Hauser, Thomas H.
    Manning, Warren J.
    [J]. AMERICAN JOURNAL OF MEDICINE, 2011, 124 (08): : 740 - 746
  • [2] TRENDS IN APPROPRIATENESS OF OUTPATIENT TRANSTHORACIC ECHOCARDIOGRAPHY
    Rahimi, Ali
    York, Meghan
    Gheewala, Neil
    Hauser, Thomas H.
    Manning, Warren J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] Prospective evaluation of the clinical application of the ACCF/ASE appropriateness criteria for transthoracic echocardiography
    Ward, R. Parker
    Lemieux, Nicole
    Gera, Nitin
    Mansour, Ibrahim N.
    Mehta, Rupa
    Lang, Roberto M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A269 - A269
  • [4] Comparison of the Clinical Application of the American College of Cardiology Foundation/American Society of Echocardiography Appropriateness Criteria for Outpatient Transthoracic Echocardiography in Academic and Community Practice Settings
    Ward, R. Parker
    Krauss, Daniel
    Mansour, Ibrahim N.
    Lemieux, Nicole
    Gera, Nitin
    Lang, Roberto M.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (12) : 1375 - 1381
  • [5] Appropriateness of use criteria for transthoracic echocardiography: are they relevant outside the USA?
    Gurzun, Maria-Magdalena
    Ionescu, Adrian
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (04) : 450 - 455
  • [6] Prospective Evaluation of the Clinical Application of the American College of Cardiology Foundation/American Society of Echocardiography Appropriateness Criteria for Transthoracic Echocardiography
    Ward, R. Parker
    Mansour, Ibrahim N.
    Lemieux, Nicole
    Gera, Nitin
    Mehta, Rupa
    Lang, Roberto M.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2008, 1 (05) : 663 - 671
  • [7] Application of Appropriate Use Criteria for Initial Transthoracic Echocardiography in an Academic Outpatient Pediatric Cardiology Program
    Safa, Raya
    Aggarwal, Sanjeev
    Misra, Amrit
    Kobayashi, Daisuke
    [J]. PEDIATRIC CARDIOLOGY, 2017, 38 (06) : 1282 - 1287
  • [8] Application of Appropriate Use Criteria for Initial Transthoracic Echocardiography in an Academic Outpatient Pediatric Cardiology Program
    Raya Safa
    Sanjeev Aggarwal
    Amrit Misra
    Daisuke Kobayashi
    [J]. Pediatric Cardiology, 2017, 38 : 1282 - 1287
  • [9] Applicability, limitations and downstream impact of echocardiography utilization based on the appropriateness use criteria for transthoracic and transesophageal echocardiography
    Mohammad Alqarqaz
    Jayanth Koneru
    Meredith Mahan
    Karthik Ananthasubramaniam
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1951 - 1958
  • [10] Applicability, limitations and downstream impact of echocardiography utilization based on the appropriateness use criteria for transthoracic and transesophageal echocardiography
    Alqarqaz, Mohammad
    Koneru, Jayanth
    Mahan, Meredith
    Ananthasubramaniam, Karthik
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1951 - 1958