Towards the clinical application of X-ray phase contrast imaging

被引:21
|
作者
Williams, I. M. [1 ]
Siu, K. K. W. [1 ,4 ]
Runxuan, G. [2 ]
He, X. [2 ]
Hart, S. A. [3 ]
Styles, C. B. [5 ]
Lewis, R. A. [1 ,4 ]
机构
[1] Monash Univ, Sch Phys, Clayton, Vic 3800, Australia
[2] Dept Med Imaging & Radiat Sci, Clayton, Vic 3800, Australia
[3] Monash Breast Surg Unit, Clayton, Vic 3168, Australia
[4] Monash Univ, Monash Ctr Synchrotron Sci, Clayton, Vic 3800, Australia
[5] Peter MacCallum Canc Inst, Clayton, Vic 8006, Australia
关键词
Mammography; Phase contrast imaging; Propagation-based imaging; X-ray;
D O I
10.1016/j.ejrad.2008.04.042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron-based propagation-based imaging, a type of phase contrast imaging, produces better soft tissue image contrast than conventional radiography. To determine whether the technique is directly transferable to the clinical environment for routine diagnostic or screening imaging, a micro-focus (100 mu m spot-size) Molybdenum X-ray source with 0.03 mm molybdenum filtration was installed at a local hospital. Breast tissue samples, excised masses and mastectomies, were obtained directly from surgery and imaged at three geometries. The first geometry was optimised for visualizing phase contrast effects using a ray-line argument, the second was the same as that employed by Konica-Minolta in their commercial phase contrast system, and the third was the conventional contact arrangement. The three images taken of each tissue sample were comparatively scored in a pair-wise fashion. Scoring was performed by radiologist expert in mammography, general radiologists, associated clinicians and radiographers on high-resolution mammography rated monitors at two separate locations. Scoring indicated that the optimised and Konica geometries both outperformed the conventional mammographic geometry. An unexpected complication within the trial was the effect that the scoring platform and the associated display tools had on some of the scorer's responses. Additionally, the trial revealed that none of the conventional descriptors for image quality were adequate in the presence of phase contrast enhancements. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:S73 / S77
页数:5
相关论文
共 50 条
  • [1] Clinical application of phase contrast x-ray
    Ha, S. H.
    Park, S. Y.
    Park, G. M.
    Lee, O. S.
    Lee, G. W.
    Oh, C. H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3753 - 3757
  • [2] Various clinical application of phase contrast X-ray
    Oh, Chilhwan
    Park, Sangyong
    Ha, Seunghan
    Park, Gyuman
    Lee, Gunwoo
    Lee, Onseok
    Je, Jungho
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VI, 2008, 6848
  • [3] X-Ray Imaging with Phase Contrast
    Bonse, Ulrich
    Beckmann, Felix
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 189 - +
  • [4] Phase contrast X-ray imaging
    Weon, Byung Mook
    Je, Jung Ho
    Hwu, Yeukuang
    Margaritondo, Giorgio
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2006, 3 (2-3) : 280 - 297
  • [5] X-ray phase contrast imaging
    Xiong, SS
    Chen, JW
    Gao, HY
    Xie, HL
    Li, RX
    Xu, ZZ
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 3715 - 3718
  • [6] Phase contrast X-ray imaging
    Biomedical Imaging Center, Department of Materials Science and Engineering, Pohang University of Science and Technology, Pohang, 790-784, Korea, Republic of
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    Int. J. Nanotechnol., 2006, 2-3 (280-297):
  • [7] Phase contrast imaging for medical diagnostics: towards clinical application with compact laser-based X-ray sources
    Coan, P.
    Diemoz, P. C.
    Bravin, A.
    Schlossbauer, T.
    Reiser, M.
    Habs, D.
    Schneider, T.
    Glaser, C.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 13, 2009, 25 (13): : 200 - +
  • [8] Towards the clinical application of X-ray phase contrast imaging (vol 68S, pg 73, 2008)
    Williams, I. M.
    Siu, K. K. W.
    Gan, R.
    He, X.
    Hart, S. A.
    Styles, C. B.
    Lewis, R. A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) : 140 - 140
  • [9] X-ray phase-contrast imaging of the breast-advances towards clinical implementation
    Auweter, S. D.
    Herzen, J.
    Willner, M.
    Grandl, S.
    Scherer, K.
    Bamberg, F.
    Reiser, M. F.
    Pfeiffer, F.
    Hellerhoff, K.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1034):
  • [10] Towards X-ray differential phase contrast imaging on a compact setup
    Thuering, T.
    Modregger, P.
    Pinzer, B. R.
    Wang, Z.
    Rutishauser, S.
    David, C.
    Grund, T.
    Kenntner, J.
    Stampanoni, M.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961