Finite Element Analysis of Newly Developed Endosseous Root-Form Dental Implant Utilizing Biodegradable Magnesium Alloy

被引:0
|
作者
Han, Hyung-Seop [1 ]
Seok, Hyun-Kwang [1 ]
Kim, Yu-Chan [2 ]
机构
[1] Ctr Biomat, Korea Inst Sci & Technol, Seoul, South Korea
[2] Univ Sci & Technol, Biomed Res Inst, Daejeon, South Korea
关键词
dental implant; fatigue life; fatigue limit; finite element; HYDROXYAPATITE-COATED IMPLANTS;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The purpose of this study was to investigate the fatigue life of an endosseous root-form dental implant using finite element analysis. A conventional Brnemark dental implant system was redesigned to utilize the biocompatible, lightweight magnesium alloy which promotes bone growth. ANSYS Workbench 11.0 was used to generate a three-dimensional mesh of a model created with the actual size specifications. Regulations and schematic of test set-up from ISO 14801 - "Fatigue test for endosseous dental implants" were strictly followed to simulate the fatigue test. To validate the credibility of calculated fatigue life, actual prototypes were built with the design specifications and tested using Material Test System 810. Result of finite element analysis displayed a close approximation of experimental fatigue behavior both displaying that the proposed implant would achieve a fatigue limit of 5 x 106 cycle suggested by the ISO at 150 N. The main advantage of performed computer simulations is that it is fast, efficient and cheap. A comparison of the calculated fatigue life with experimental fatigue life data displayed the accuracy and reliability of the computer simulation method.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 12 条
  • [1] Simulation study on uneven expansion behaviour of biodegradable magnesium alloy stents by finite element analysis
    Li, J.
    Mao, Z.
    Zheng, F.
    Tan, L.
    Yang, K.
    MATERIALS SCIENCE AND TECHNOLOGY, 2014, 30 (05) : 527 - 533
  • [2] The Construction and Analysis of the Three-dimensional Finite Element Model of Dental Implant and Root Bisection Joint Prosthesis
    Ji, Chen
    Chen, Ling
    Wang, Shaokai
    Zhang, Zhong
    2014 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2014), 2014, : 1264 - 1268
  • [3] Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
    Ding, Kai
    Yang, Weijie
    Zhu, Jian
    Cheng, Xiaodong
    Wang, Haicheng
    Hao, Du
    Song Yinuo
    Zhu, Yanbin
    Zhang, Yingze
    Chen, Wei
    Zhang, Qi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [4] Titanium Alloy Gamma Nail versus Biodegradable Magnesium Alloy Bionic Gamma Nail for Treating Intertrochanteric Fractures: A Finite Element Analysis
    Li, Ming
    Zhao, Kuo
    Ding, Kai
    Cui, Yun-wei
    Cheng, Xiao-dong
    Yang, Wei-jie
    Hou, Zhi-yong
    Zhang, Ying-ze
    Chen, Wei
    Hu, Pan
    Zhu, Yan-bin
    ORTHOPAEDIC SURGERY, 2021, 13 (05) : 1513 - 1520
  • [5] Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
    Kai Ding
    Weijie Yang
    Jian Zhu
    Xiaodong Cheng
    Haicheng Wang
    Du Hao
    Song Yinuo
    Yanbin Zhu
    Yingze Zhang
    Wei Chen
    Qi Zhang
    Journal of Orthopaedic Surgery and Research, 16
  • [6] FINITE ELEMENT ANALYSIS OF RESIDUAL STRESSES IN HIGH-SPEED DRY CUTTING OF BIODEGRADABLE MAGNESIUM-CALCIUM ALLOY
    Salahshoor, M.
    Guo, Y. B.
    PROCEEDINGS OF THE ASME INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, 2012, 2012, : 397 - 404
  • [7] Design and Mechanical Performance Evaluation of WE43 Magnesium Alloy Biodegradable Stents via Finite Element Analysis
    Chen, Jiaxuan
    Dong, Fang
    Liu, Sheng
    METALS, 2024, 14 (06)
  • [8] MICRO-COMPUTED TOMOGRAPHY TO FINITE ELEMENT ANALYSIS OF IN VIVO BIODEGRADABLE MAGNESIUM -ALLOY SCREW AND SURROUNDING BONE IN RABBIT FEMURS
    Williams, Adrienne F. O.
    McCullough, Matthew B. A.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL. 14, 2016,
  • [9] A 3-DIMENSIONAL FINITE-ELEMENT ANALYSIS OF A POROUS ROOTED CO-CR-MO ALLOY DENTAL IMPLANT
    COOK, SD
    WEINSTEIN, AM
    KLAWITTER, JJ
    JOURNAL OF DENTAL RESEARCH, 1982, 61 (01) : 25 - 29
  • [10] Influence of Different Abutment Designs on the Biomechanical Behavior of Dental Root-Analog Implant: A Three-Dimensional Finite Element Analysis
    He, Ling
    Li, Deli
    Zhang, Jiwu
    Li, Xiucheng
    Lu, Songhe
    Tang, Zhihui
    Implant Dentistry, 2016, 25 (06) : 802 - 806