Behavior of FRP-Steel Confined Concrete Tubular Columns Made of Expansive Self-Consolidating Concrete under Axial Compression

被引:47
|
作者
Cao, Qi [1 ,2 ]
Tao, Jinju [1 ]
Wu, Zhimin [1 ]
Ma, Zhongguo John [3 ,4 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Ocean Engn Joint Res Ctr DUT UWA, Dalian 116024, Peoples R China
[3] Univ Tennessee, Dept Civil & Environm Engn, 313 John D Tickle Bldg, Knoxville, TN 37996 USA
[4] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber-reinforced polymer (FRP); Prestress; Columns; Expansive self-consolidating concrete (ESCC); Steel tube; STRESS-STRAIN MODEL; FLEXURAL BEHAVIOR; FIBER COMPOSITES; DESIGN; MEMBERS; BEAMS;
D O I
10.1061/(ASCE)CC.1943-5614.0000818
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 32 fiber-reinforced polymer (FRP) confined concrete columns are manufactured and tested under axial compression including 8 FRP-confined solid columns (FCSCs), 4 FRP-confined concrete-filled steel tube columns (CCFTs), and 20 hybrid FRP-concrete-steel double-skin tubular columns (DSTCs). Key parameters include FRP layers, diameter of steel tube, and presence or absence of an expansive agent and concrete filling for the steel tube. Due to the effect of the expansive agent, prestress in concrete is detected in all specimens with expansive self-consolidating concrete (ESCC). For FCSCs and CCFTs, the normalized intercept, inflection and ultimate load for ESCC specimens are higher than those of self-consolidating concrete (SCC) specimens. For DSTCs, when the inner steel tube is filled with concrete only normalized ultimate loads are improved by in ESCC specimens compared with SCC specimens. For hollow DSTCs, however, an expansive agent does not improve the axial behavior. The number of layers of FRP show a positive influence on the normalized intercept, inflection, and ultimate load of ESCC FCSC specimens. In addition, test results for hollow DSTCs indicate that normalized ultimate loads decrease with the increase of steel tube diameter. An existing model used to predict the compressive strength and ultimate axial strain of FCSCs shows good agreement. (c) 2017 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Self-consolidating concrete columns under concentric compression
    Lin, Chien-Hung
    Hwang, Chao-Lung
    Lin, Shih-Ping
    Liu, Chih-Hsiuan
    ACI STRUCTURAL JOURNAL, 2008, 105 (04) : 425 - 432
  • [2] Self-consolidating concrete piles confined in FRP tubes
    El-Chabib, H
    Nehdi, M
    El Naggar, MH
    INNOVATIONS IN DESIGN WITH EMPHASIS ON SEISMIC, WIND, AND ENVIRONMENTAL LOADING: QUALITY CONTROL AND INNOVATIONS IN MATERIALS/HOT-WEATHER CONCRETING, 2002, 209 : 297 - 318
  • [3] Behavior of concrete-filled FRP tube columns internally reinforced with FRP-steel composite bars under axial compression
    Guo, Yong-Chang
    Xiao, Shu-Hua
    Zeng, Jun-Jie
    Su, Jia-Ying
    Li, Tian-Zi
    Xie, Zhi-Hong
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 315
  • [4] Structural performance of self-consolidating concrete used in confined concrete columns
    Paultre, P
    Khayat, KH
    Cusson, D
    Tremblay, S
    ACI STRUCTURAL JOURNAL, 2005, 102 (04) : 560 - 568
  • [5] FRP-confined circular concrete-filled steel tubular columns under cyclic axial compression
    Yu, T.
    Hu, Y. M.
    Teng, J. G.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 94 : 33 - 48
  • [6] Experimental investigation into FRP-confined concrete-filled steel tubular columns under axial compression
    Ma, Lu
    Zhou, Changlin
    Zhang, Ji
    MAGAZINE OF CONCRETE RESEARCH, 2023, 75 (03) : 109 - 122
  • [7] Seismic behavior of square concrete columns confined by FRP-steel composite tube
    Wang, Yanlei
    Cai, Gaochuang
    JOURNAL OF BUILDING ENGINEERING, 2023, 65
  • [8] Mechanical behaviour of concrete filled double skin steel tubular stub columns confined by FRP under axial compression
    Wang, Jun
    Liu, Weiqing
    Zhou, Ding
    Zhu, Lu
    Fang, Hai
    STEEL AND COMPOSITE STRUCTURES, 2014, 17 (04): : 431 - 452
  • [9] Experimental investigations of FRP-interlayer-steel confined concrete columns under axial compression
    Hu, Qing
    Liu, Changyong
    Wang, Yuyin
    Zhang, Sumei
    Yu, Tao
    STRUCTURES, 2022, 43 : 1002 - 1017
  • [10] Analytical model of concrete-filled FRP-steel composite tube columns under cyclic axial compression
    Zhang, Yirui
    Wei, Yang
    Zhao, Kang
    Ding, Mingmin
    Wang, Libin
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 139