OPTICAL LAYOUT ANALYSIS OF POLARIZATION INTERFERENCE IMAGING SPECTROMETER BY JONES CALCULUS IN VIEW OF BOTH OPTICAL THROUGHPUT AND INTERFERENCE FRINGE VISIBILITY

被引:0
|
作者
Zhang, Xuanni [1 ,2 ]
Zhang, Chunmin [1 ]
机构
[1] Xi An Jiao Tong Univ, Minist Educ Key Lab Nonequilibrium Synth & Modula, Sch Sci, Xian 710049, Peoples R China
[2] Xianyang Normal Univ, Inst Phys & Elect Engn, Xianyang 712000, Peoples R China
来源
MODERN PHYSICS LETTERS B | 2013年 / 27卷 / 02期
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
Polarization components; optical throughput; Jones calculus; optical layout; interference fringe visibility; UPPER ATMOSPHERIC WIND; SPECTRUM RECONSTRUCTION; PATH DIFFERENCE; INTERFEROGRAM; ORIENTATION;
D O I
10.1142/S0217984913500127
中图分类号
O59 [应用物理学];
学科分类号
摘要
A polarization interference imaging spectrometer based on Savart polariscope was presented. Its optical throughput was analyzed by Jones calculus. The throughput expression was given, and clearly showed that the optical throughput mainly depended on the intensity of incident light, transmissivity, refractive index and the layout of optical system. The simulation and analysis gave the optimum layout in view of both optical throughput and interference fringe visibility, and verified that the layout of our former design was optimum. The simulation showed that a small deviation from the optimum layout influenced interference fringe visibility little for the optimum one, but influenced severely for others, so a small deviation is admissible in the optimum, and this can mitigate the manufacture difficulty. These results pave the way for further research and engineering design.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Calculation of the optical path difference and fringe location in polarization interference imaging spectrometer
    Mu Ting-Kui
    Zhang Chun-Min
    Zhao Bao-Chang
    ACTA PHYSICA SINICA, 2009, 58 (06) : 3877 - 3886
  • [2] Calculation and analysis of optical flux throughput of interference imaging spectrometer
    Bai Xin
    Zhang Chun-Min
    Jing Chun-Yuan
    Guan Xiao-Wei
    Cao Fen
    Li Yan-Na
    Xie Lin-Li
    ACTA PHYSICA SINICA, 2011, 60 (07)
  • [3] Interference visibility of the wide-field-of-view polarization interference imaging spectrometer (WPIIS)
    Wu, Haiying
    Zhang, Sanxi
    Zhang, Chunmin
    OPTICS COMMUNICATIONS, 2014, 333 : 99 - 104
  • [4] Optical throughput of the tempo-spatially modulated polarization interference imaging spectrometer
    Ai, Jingjing
    Zhang, Chunmin
    Jia, Chenling
    Gao, Peng
    OPTIK, 2013, 124 (22): : 5751 - 5755
  • [5] Analysis of the throughput of onboard polarization interference imaging spectrometer
    Zhang, CM
    Zhao, BC
    Yuan, Y
    He, J
    ICO20: MEM, MOEMS, AND NEMS, 2006, 6032
  • [6] Optical path difference evaluation of the polarization interference imaging spectrometer
    Mu, Tingkui
    Zhang, Chunmin
    Zhao, Baochang
    OPTICS COMMUNICATIONS, 2009, 282 (10) : 1984 - 1992
  • [7] Analysis of the lateral displacement and optical path difference in wide-field-of-view polarization interference imaging spectrometer
    Wu, Lei
    Zhang, Chunmin
    Zhao, Baochang
    OPTICS COMMUNICATIONS, 2007, 273 (01) : 67 - 73
  • [8] Throughput of a polarization interference imaging spectrometer in remote sensing
    Gao, Hongwen
    Zhang, Chunmin
    NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES IV, 2011, 8032
  • [9] Interference visibility of wide-field-of-view polarization interference imaging spetrometer
    Wu, Haiying
    Zhang, Sanxi
    Wang, Weiqiang
    Zhang, Weiguang
    Zhang, Yulun
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2014, 43 (01): : 201 - 207
  • [10] The polarization-difference interference imaging spectrometer-II. optical design and analysis
    Mu Ting-Kui
    Zhang Chun-Min
    Li Qi-Wei
    Wei Yu-Tong
    Chen Qing-Ying
    Jia Chen-Ling
    ACTA PHYSICA SINICA, 2014, 63 (11)