Verification of a Calibration Method for Digital to Analog Converters

被引:0
|
作者
Marin, Mihai-Eugen [1 ]
Constantinescu, Florin [1 ]
Brinzei, Catalin [2 ]
Gheorghe, Alexandru [1 ]
机构
[1] Univ Politehn Bucuresti, Dept Elect Engn, Bucharest, Romania
[2] Infineon Technol Romania SCS, Bucharest, Romania
关键词
Calibration methods; digital to analog converters; high speed DAC; SFDR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new calibration method for digital to analog converters (DAC) is verified, measuring a set of chips, each containing a 8 bit current steering DAC with a 5+3 segmented architecture. For a sampling frequency of 500MHz and a bandwidth of 5MHz all tested circuits exhibited, after calibration, a Spurious Free Dynamic Range (SFDR) better than 50dB. For a sampling frequency of 1GHz and a bandwidth of 10MHz, a SFDR better than 40dB resulted for all tested cases. These last results could be explained by a degradation of the digital signal supplied by the FPGA board, which has a maximum reliable clock frequency of 600MHz, and by the influence of the parasitic elements introduced by the PCB traces. In all measured cases an improvement of 2-4dB of the SFDR value has been obtained using the proposed calibration method.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] CALIBRATION OF DIGITAL-ANALOG CONVERTERS
    SCHEINBERG, S
    ARCHIVE FOR RATIONAL MECHANICS AND ANALYSIS, 1973, 52 (03) : 261 - 265
  • [2] New adaptive calibration method for time interleaved Analog to Digital Converters
    Jridi, Maher
    Bossuet, Lilian
    Le Gal, Bertrand
    Dallet, Dominique
    2007 IEEE NORTH-EAST WORKSHOP ON CIRCUITS AND SYSTEMS, 2007, : 159 - 162
  • [3] New approach for digital calibration of pipelined analog to digital converters based on secant method
    Zia, Ehsan
    Shamsi, Alireza
    Mazloum, Jalil
    INTEGRATION-THE VLSI JOURNAL, 2022, 82 : 89 - 95
  • [4] On external calibration of analog-to-digital converters
    Lundin, H
    Skoglund, M
    Händel, P
    2001 IEEE WORKSHOP ON STATISTICAL SIGNAL PROCESSING PROCEEDINGS, 2001, : 377 - 380
  • [5] On the Calibration of Wideband Analog-Digital Converters
    Medawar, Samer
    Haendel, Peter
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (08) : 2353 - 2355
  • [6] An offset and gain calibration method for time-interleaved analog to digital converters
    Jridi, M.
    Monnerie, G.
    Bossuet, L.
    Dallet, D.
    2006 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2006, : 1097 - 1100
  • [7] A digital calibration technique for pipelined analog-to-digital converters
    Furuta, M
    Kawahito, S
    Miyazaki, D
    IMTC 2002: PROCEEDINGS OF THE 19TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 & 2, 2002, : 713 - 717
  • [8] Calibration Technique for SAR Analog-to-Digital Converters
    Tong, Tao
    Yu, Wenhuan
    Hanumolu, Pavan K.
    Temes, Gabor C.
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012,
  • [9] Calibration technique for SAR analog-to-digital converters
    Tong, Tao
    Yu, Wenhuan
    Hanumolu, Pavan K.
    Temes, Gabor C.
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2012, 73 (01) : 301 - 309
  • [10] Calibration and error compensation of analog to digital scan converters
    Arpaia, P
    Cennamo, F
    Daponte, P