Removing organic and nitrogen content from a highly saline municipal wastewater reverse osmosis concentrate by UV/H2O2-BAC treatment

被引:48
|
作者
Pradhan, Shovana [1 ]
Fan, Linhua [1 ]
Roddick, Felicity A. [1 ]
机构
[1] RMIT Univ, Sch Civil Environm & Chem Engn, Melbourne, Vic 3001, Australia
关键词
Reverse osmosis concentrate; Biological activated carbon; Advanced oxidation processes; Organic matter removal; Nitrogen removal; Wastewater reclamation; BIOLOGICAL ACTIVATED CARBON; HYDROGEN-PEROXIDE; AQUACULTURE SYSTEM; SODIUM-SALICYLATE; SALT INHIBITION; DENITRIFICATION; RECLAMATION; NITRIFICATION; OXIDATION; DEGRADATION;
D O I
10.1016/j.chemosphere.2015.05.028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Reverse osmosis (RO) concentrate (ROC) streams generated from RO-based municipal wastewater reclamation processes pose potential health and environmental risks on their disposal to confined water bodies such as bays. A UV/H2O2 advanced oxidation process followed by a biological activated carbon (BAC) treatment was evaluated at lab-scale for the removal of organic and nutrient content from a highly saline ROC (TDS 16 g L-1, EC 23.5 mS cm(-1)) for its safe disposal to the receiving environment. Over the 230-day operation of the UV/H2O2-BAC process, the colour and UV absorbance (254 nm) of the ROC were reduced to well below those of the influent to the reclamation process. The concentrations of DOC and total nitrogen (TN) were reduced by approximately 60% at an empty bed contact time (EBCT) of 60 min. The reduction in ammonia nitrogen by the BAC remained high under all conditions tested (>90%). Further investigation confirmed that the presence of residual peroxide in the UV/H2O2 treated ROC was beneficial for DOC removal, but markedly inhibited the activities of the nitrifying bacteria (i.e., nitrite oxidising bacteria) in the BAC system and hence compromised total nitrogen removal. This work demonstrated that the BAC treatment could be acclimated to the very high salinity environment, and could be used as a robust method for the removal of organic matter and nitrogen from the pre-oxidised ROC under optimised conditions. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [1] Potential of BAC combined with UVC/H2O2 for reducing organic matter from highly saline reverse osmosis concentrate produced from municipal wastewater reclamation
    Lu, Jie
    Fan, Linhua
    Roddick, Felicity A.
    CHEMOSPHERE, 2013, 93 (04) : 683 - 688
  • [2] Comparison of UV/H2O2 and UV/PS processes for the treatment of reverse osmosis concentrate from municipal wastewater reclamation
    Lee, Min-Yong
    Wang, Wen-Long
    Du, Ye
    Wu, Qian-Yuan
    Huang, Nan
    Xu, Zi-Bin
    Hu, Hong-Ying
    CHEMICAL ENGINEERING JOURNAL, 2020, 388
  • [3] Effect of coagulation on treatment of municipal wastewater reverse osmosis concentrate by UVC/H2O2
    Umar, Muhammad
    Roddick, Felicity
    Fan, Linhua
    JOURNAL OF HAZARDOUS MATERIALS, 2014, 266 : 10 - 18
  • [4] Impact of salinity and pH on the UVC/H2O2 treatment of reverse osmosis concentrate produced from municipal wastewater reclamation
    Liu, Kai
    Roddick, Felicity A.
    Fan, Linhua
    WATER RESEARCH, 2012, 46 (10) : 3229 - 3239
  • [5] Comparison of O3-BAC, UV/H2O2-BAC, and O3/H2O2-BAC treatments for limiting the formation of disinfection byproducts during drinking water treatment in India
    Tak, Surbhi
    Vellanki, Bhanu Prakash
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (05):
  • [6] Trace Organic Compound Removal from Wastewater Reverse-Osmosis Concentrate by Advanced Oxidation Processes with UV/O3/H2O2
    Kaplan, Aviv
    Mamane, Hadas
    Lester, Yaal
    Avisar, Dror
    MATERIALS, 2020, 13 (12) : 1 - 13
  • [7] Impact of coagulation as a pre-treatment for UVC/H2O2-biological activated carbon treatment of a municipal wastewater reverse osmosis concentrate
    Umar, Muhammad
    Roddick, Felicity
    Fan, Linhua
    WATER RESEARCH, 2016, 88 : 12 - 19
  • [8] Treatment of municipal wastewater reverse osmosis concentrate using UVC-LED/H2O2 with and without coagulation pre-treatment
    Umar, M.
    Roddick, F. A.
    Fan, L.
    Autin, O.
    Jefferson, B.
    CHEMICAL ENGINEERING JOURNAL, 2015, 260 : 649 - 656
  • [9] Applications of UV/H2O2, UV/persulfate, and UV/persulfate/Cu2+ for the elimination of reverse osmosis concentrate generated from municipal wastewater reclamation treatment plant: Toxicity, transformation products, and disinfection byproducts
    Lee, Min-Yong
    Wang, Wen-Long
    Du, Ye
    Jeon, Tae-Wan
    Shin, Sun-Kyung
    Wu, Qian-Yuan
    Dao, Guo-Hua
    Hu, Hong-Ying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 762
  • [10] A mini review on treatment alternatives removing organic pollutants for reverse osmosis concentrate from industrial wastewater sources
    Liu, Yaqian
    Mo, Yinghui
    Zhao, Xin
    Wang, Shenghui
    Wang, Liang
    Guo, Heng
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2025, 13 (03):