Performance evaluation of cylindrical fiber optic light diffusers for biomedical applications

被引:46
|
作者
Vesselov, LM
Whittington, W
Lilge, L
机构
[1] Univ Hlth Network, Toronto, ON M5G 2M9, Canada
[2] Walsh Med Devices Inc, Oakville, ON L6L 5T7, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
light delivery; optical radiation measurement; photodynamic therapy; interstitial laser hyperthermia; interstitial photocoagulation;
D O I
10.1002/lsm.20031
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: Dosimetry for intracavity and interstitial light delivery requires next to the knowledge of tissue optical properties and models describing light propagation in tissue also exact knowledge of the spatial light source emission characteristics. However, the emission characteristics of cylindrical diffusers are often ill defined by the manufacturer, and not regularly determined by the end user, thus limiting the attainable dosimetry accuracy. Study Design/Materials and Methods: Commercial cylindrical diffusers, with active diffusive lengths of 12 cm and outer diameters of less than or equal to1 mm, were evaluated regarding their photometric emission characteristics. In addition to traditional tests of homogeneity such as light intensity emitted along the diffuser length and around its circumference (polar angle), azimuth emission was also measured. Results: It was demonstrated that the light emission distribution is specific to the diffuser manufacturer, and while good polar isotropy is often attained, azimuth isotropy can vary by more than a factor of 5. In hollow organs the latter can result in over treatment of tissue distal to the actual placement of the cylindrical diffusers. Conclusions: To enable light dosimetry and treatment planning for applications such as photodynamic therapy or interstitial laser hyperthermia or photocoagulation, standardization of emission properties reporting for optical fiber diffusers is required. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:348 / 351
页数:4
相关论文
共 50 条
  • [1] Fiber Optic Sensors for Biomedical Applications
    Baldini, Francesco
    Giannetti, Ambra
    Mencaglia, Andrea A.
    Trono, Cosimo
    CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (04) : 378 - 390
  • [2] Fiber optic pressure sensor for biomedical applications
    Narendran, N
    Corbo, MA
    Smith, W
    ASAIO JOURNAL, 1996, 42 (05) : M500 - M506
  • [3] A FIBER OPTIC ANGULAR SENSOR FOR BIOMEDICAL APPLICATIONS
    JENSEN, JC
    LI, JKJ
    SIGEL, G
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1118 - 1119
  • [4] Biomedical Fiber Optic Sensor Applications A Tutorial
    Mendez, Alexis
    2015 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION (OFC), 2015,
  • [5] FIBER-OPTIC SENSORS FOR BIOMEDICAL APPLICATIONS
    PETERSON, JI
    VUREK, GG
    SCIENCE, 1984, 224 (4645) : 123 - 127
  • [6] Performance characteristics of thin cylindrical diffusers coupled to glass optical fiber
    Vesselov, L
    Whittington, W
    Lilge, L
    LASERS IN SURGERY AND MEDICINE, 2004, : 43 - 43
  • [7] Effect of elastomer characteristics on fiber optic force sensing performance in biomedical robotics applications
    Park, Kihong
    Kim, Changmin
    Kulkarni, Atul
    Shin, Dongjoo
    Kim, Hyeong-U
    Kim, Kyunghoon
    Kim, Taesung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (12) : 5631 - 5636
  • [8] Effect of elastomer characteristics on fiber optic force sensing performance in biomedical robotics applications
    Kihong Park
    Changmin Kim
    Atul Kulkarni
    Dongjoo Shin
    Hyeong-U Kim
    Kyunghoon Kim
    Taesung Kim
    Journal of Mechanical Science and Technology, 2018, 32 : 5631 - 5636
  • [9] A fiber-optic pressure microsensor for biomedical applications
    Tohyama, O
    Kohashi, M
    Fukui, M
    Itoh, H
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 1489 - 1492
  • [10] Optoacoustic fiber optic interferometric sensors for biomedical applications
    Gallego, Daniel
    Lamela, Horacio
    FIBER OPTIC SENSORS AND APPLICATIONS VIII, 2011, 8028