The influence of ultrasound guidance in the rate of success of acromioclavicular joint injection: an experimental study on human cadavers

被引:29
|
作者
Borbas, Paul [1 ,4 ]
Kraus, Tanja [2 ]
Clement, Hans [3 ]
Grechenig, Stefan [4 ]
Weinberg, Annelie-Martina [5 ]
Heidari, Nima [3 ]
机构
[1] Univ Zurich, Dept Orthoped, CH-8008 Zurich, Switzerland
[2] Med Univ Graz, Pediat Orthopaed Unit, Dept Pediat Surg, Graz, Austria
[3] Med Univ Graz, Dept Traumatol, Graz, Austria
[4] Med Univ Graz, Inst Anat, Graz, Austria
[5] Med Univ Graz, Dept Pediat Surg, Graz, Austria
关键词
Shoulder; acromioclavicular; AC joint; arthritis; joint injection; sonographic guidance; SUCCESSFUL INTRAARTICULAR PUNCTURE; STEROID INJECTIONS; ACCURACY; FREQUENCY; SHOULDER; CORTISOL; TENDONS; ANKLE; FOOT; SKIN;
D O I
10.1016/j.jse.2011.11.036
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Injections of the acromioclavicular joint (ACJ) are performed routinely in patients with ACJ arthritis, both diagnostically and therapeutically. The aim of this prospective controlled study was to estimate the frequency of successful intra-articular ACJ injections with the aid of sonographic guidance versus non-guided ACJ injections. Materials and methods: A total of 80 cadaveric ACJs were injected with a solution containing methylene blue and subsequently dissected to distinguish intra-from peri-articular injections. In 40 cases the joint was punctured with sonographic guidance, whereas 40 joints were injected in the control group without the aid of ultrasound. Results: The rate of successful intra-articular ACJ injection was 90% (36 of 40) in the guided group and 70% (28 of 40) in the non-guided group. Ultrasound was significantly more accurate for correct intra-articular needle placement (P=.025). Discussion: The use of ultrasound significantly improves the accuracy of ACJ injection. Level of evidence: Basic Science Study, Anatomic Study, Cadaveric Model. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1694 / 1697
页数:4
相关论文
共 50 条
  • [41] Two-point ultrasound-guided transversus abdominis plane injection in canine cadavers - a pilot study
    Johnson, Emma K.
    Bauquier, Sebastien H.
    Carter, Jennifer E.
    Whittem, Ted
    Beths, Thierry
    VETERINARY ANAESTHESIA AND ANALGESIA, 2018, 45 (06) : 871 - 875
  • [42] Ultrasound-Guided Prolotherapy for Acromial Enthesopathy and Acromioclavicular Joint Arthropathy: A Single-Arm Prospective Study
    Hsieh, Pei-Chun
    Chiou, Hong-Jen
    Wang, Hsin-Kai
    Lai, Yi-Chen
    Lin, Yung-Hui
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (03) : 605 - 612
  • [43] Study on the Influence of Safety Injection Rate on the Process of SBLOCA
    Hui, He
    Pan, Liang-ming
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [44] Anatomical differences in Sacral hiatus during caudal epidural injection with ultrasonography guidance and its effects on success rate
    Gokcek, Erhan
    Kaydu, Ayhan
    AGRI-THE JOURNAL OF THE TURKISH SOCIETY OF ALGOLOGY, 2020, 32 (01): : 19 - 24
  • [45] Ultrasound guidance improves success rate of axillary brachial plexus block (vol 54, pg 176, 2007)
    Chan, V. W. S.
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (07): : 594 - 594
  • [46] Indirect Ultrasound Guidance Increased Accuracy of the Glenohumeral Injection Using the Superior Approach: A Cadaveric Study of Injection Accuracy
    Kim, Joon Sung
    Kim, Min-Wook
    Park, Dong Yoon
    ANNALS OF REHABILITATION MEDICINE-ARM, 2013, 37 (02): : 202 - 207
  • [47] Evaluation of the effect of ultrasound guidance on the accuracy of intercostal nerve injection: a canine cadaveric study
    Thomson, Alexander C. S.
    Portela, Diego A.
    Romano, Marta
    Otero, Pablo E.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2021, 48 (02) : 256 - 263
  • [48] Accuracy of intraoral ultrasound to evaluate alveolar bone level: an ex vivo study in human cadavers
    Corbea, Claudiu
    Le, Lawrence H.
    Kaipatur, Neelambar R.
    Li, Mengxun
    Nguyen, Kim Cuong
    Heo, Giseon
    Figueredo, Carlos Alberto
    Major, Paul W.
    Almeida, Fabiana T.
    ORAL RADIOLOGY, 2025, 41 (01) : 33 - 40
  • [49] Experimental And Numerical Study Of The Biomechanics Of A Human Joint
    Aoun, Mhamad
    Ramos, Antonio
    Mesnard, Michel
    2015 INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2015, : 230 - 233
  • [50] Influence of the ferrite rate on the tenacity of a welded joint in austenitic stainless steel: Experimental study and numerical modelling
    Bouchouicha, B.
    Zemri, M.
    Benguediab, M.
    Imad, A.
    COMPUTATIONAL MATERIALS SCIENCE, 2009, 45 (02) : 336 - 341