On-line dynamic fractionation and automatic determination of inorganic phosphorus in environmental solid substrates exploiting sequential injection microcolumn extraction and flow injection analysis

被引:15
|
作者
Buanuam, Janya
Miro, Manuel
Hansen, Elo Harald
Shiowatana, Juwadee
机构
[1] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Illes Balears, Spain
[2] Mahidol Univ, Fac Sci, Dept Chem, Bangkok 10400, Thailand
[3] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
关键词
sequential injection; dynamic fractionation; inorganic phosphorus; soil;
D O I
10.1016/j.aca.2006.03.114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil-containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified by the partitioning of inorganic phosphorus in agricultural soils. The on-line fractionation method capitalises on the accurate metering and sequential exposure of the various extractants to the solid sample by application of programmable flow as precisely coordinated by a syringe pump. Three different soil phase associations for phosphorus, that is, exchangeable, Al- and Fe-bound, and Ca-bound fractions, were elucidated by accommodation in the flow manifold of the three steps of the Hieltjes-Lijklema (HL) scheme involving the use of 1.0 M NH4 Cl, 0.1 M NaOH and 0.5 M HCl, respectively, as sequential leaching reagents. The precise timing and versatility of SI for tailoring various operational extraction modes were utilized for investigating the extractability and the extent of phosphorus re-distribution for variable partitioning times. Automatic spectrophotometric determination of soluble reactive phosphor-us in soil extracts was performed by a flow injection (H) analyser based on the Molybdenum Blue (MB) chemistry. The 3 sigma detection limit was 0.02 mg P L-1 while the linear dynamic range extended up to 20 mg P L-1 regardless of the extracting media. Despite the variable chemical composition of the HL extracts, a single FI set-up was assembled with no need for either manifold re-configuration or modification of chemical composition of reagents. The mobilization of trace elements, such as Cd, often present in grazed pastures as a result of the application of phosphate fertilizers, was also explored in the HL fractions by electrothermal atomic absorption spectrometry. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
  • [1] Recent advances in on-line solvent extraction exploiting flow injection/sequential injection analysis
    Miró, M
    Estela, JM
    Cerdà, V
    CURRENT ANALYTICAL CHEMISTRY, 2005, 1 (03) : 329 - 343
  • [2] Miniaturisation and automation of metal fractionation schemes applied to environmental solid samples by sequential injection microcolumn extraction procedures
    Miró, M
    Hansen, EH
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (04) : 878 - 880
  • [3] Miniaturisation and automation of metal fractionation schemes applied to environmental solid samples by sequential injection microcolumn extraction procedures
    Manuel Miró
    Elo Harald Hansen
    Analytical and Bioanalytical Chemistry, 2005, 382 : 878 - 880
  • [4] Optimization of flow injection on-line microcolumn preconcentration of ultratrace elements in environmental samples prior to their spectrochemical determination
    Horvath, Z
    Lasztity, A
    ZihPerenyi, K
    Levai, A
    MICROCHEMICAL JOURNAL, 1996, 54 (04) : 391 - 401
  • [5] Flow Injection Amperometric Detection and Off-line Sequential Extraction Column for Fractionation of Phosphorus in Sediment
    Insain, Pimporn
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2017, 44 (03): : 965 - 976
  • [6] Sequential Injection Analysis System Exploiting On-line Solid-phase Extraction for the Determination of Strontium and Nickel by Microwave Plasma Atomic Emission Spectrometry
    Alejandro Ayala
    Yoshitaka Takaga
    Analytical Sciences, 2018, 34 : 387 - 390
  • [7] Sequential Injection Analysis System Exploiting On-line Solid-phase Extraction for the Determination of Strontium and Nickel by Microwave Plasma Atomic Emission Spectrometry
    Ayala, Alejandro
    Takagai, Yoshitaka
    ANALYTICAL SCIENCES, 2018, 34 (03) : 387 - 390
  • [8] ON-LINE MINI-COLUMN SOLID-PHASE EXTRACTION COUPLED WITH SEQUENTIAL INJECTION FOR THE DETERMINATION OF CADMIUM IN ENVIRONMENTAL SAMPLES
    Zhu, Guifen
    Wang, Haibo
    Gao, Xia
    Fan, Jing
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (03) : 320 - 330
  • [9] Using on-line solid phase extraction for simultaneous determination of ascorbic acid and rutin trihydrate by sequential injection analysis
    Legnerová, Z
    Satínsky, D
    Solich, P
    ANALYTICA CHIMICA ACTA, 2003, 497 (1-2) : 165 - 174
  • [10] Using on-line solid phase extraction for determination of amiloride in human urine by sequential injection technique
    Huclova, Jitka
    Satinsky, Dalibor
    Pavlicek, Ondrej
    Vedralova, Lucie
    Karlicek, Rolf
    ANALYTICA CHIMICA ACTA, 2006, 573 : 376 - 382