The reliability of topographic measurements from navigated transcranial magnetic stimulation in healthy volunteers and tumor patients

被引:26
|
作者
Zdunczyk, Anna [1 ]
Fleischmann, Robert [2 ]
Schulz, Juliane [1 ]
Vajkoczy, Peter [1 ]
Picht, Thomas [1 ]
机构
[1] Charite, Dept Neurosurg, D-13353 Berlin, Germany
[2] Charite, Dept Neurol, D-13353 Berlin, Germany
关键词
Navigated transcranial magnetic stimulation (nTMS); Intraexaminer reliability; Interexaminer reliability; Measurement consistency; Motor mapping; Non-invasive mapping; HUMAN MOTOR CORTEX; EVOKED-POTENTIALS; THRESHOLD; MAPS;
D O I
10.1007/s00701-013-1665-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Navigated transcranial magnetic stimulation (nTMS) is increasingly being used for preoperative mapping of the motor cortex. Any new technology should undergo rigorous validation before being widely adopted in routine clinical practice. The aim of this experimental study was to assess the intraexaminer and interexaminer reliability of topographic mapping with nTMS. Methods nTMS mapping of the motor cortex for the first dorsal interosseous (FDI) muscle was performed by an expert and a novice examiner, twice in ten healthy volunteers and once in ten tumor patients. The distances between the centers-of-gravity and hotspots were calculated, as were coefficients of variation. This study also compared orthogonal versus variable orientation of the stimulation coil. Results The mean (range) distance between centers-of-gravity for the expert examiner in the test-retest protocol with healthy volunteers was 4.40 (1.86-7.68) mm. Themean (range) distance between centers-of-gravity for the expert vs. novice examiner was 4.89 (2.39-9.22) mm. There were no significant differences in this result between healthy volunteers and tumor patients. Conclusions nTMS is sufficiently reliable for clinical use, but examiners should make efforts to minimize sources of error. The reliability of nTMS in tumor patients appears comparable to healthy subjects.
引用
收藏
页码:1309 / 1317
页数:9
相关论文
共 50 条
  • [1] The reliability of topographic measurements from navigated transcranial magnetic stimulation in healthy volunteers and tumor patients
    Anna Zdunczyk
    Robert Fleischmann
    Juliane Schulz
    Peter Vajkoczy
    Thomas Picht
    Acta Neurochirurgica, 2013, 155 : 1309 - 1317
  • [2] Navigated transcranial magnetic stimulation
    Ruohonen, J.
    Karhu, J.
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2010, 40 (01): : 7 - 17
  • [3] Evoking visual neglect-like deficits in healthy volunteers – an investigation by repetitive navigated transcranial magnetic stimulation
    Katrin Giglhuber
    Stefanie Maurer
    Claus Zimmer
    Bernhard Meyer
    Sandro M. Krieg
    Brain Imaging and Behavior, 2017, 11 : 17 - 29
  • [4] Evoking visual neglect-like deficits in healthy volunteers - an investigation by repetitive navigated transcranial magnetic stimulation
    Giglhuber, Katrin
    Maurer, Stefanie
    Zimmer, Claus
    Meyer, Bernhard
    Krieg, Sandro M.
    BRAIN IMAGING AND BEHAVIOR, 2017, 11 (01) : 17 - 29
  • [5] Motor Potentials Evoked by Navigated Transcranial Magnetic Stimulation in Healthy Subjects
    Saisanen, Laura
    Julkunen, Petro
    Niskanen, Eini
    Danner, Nils
    Hukkanen, Taina
    Lohioja, Tarja
    Nurkkala, Jouka
    Mervaala, Esa
    Karhu, Jari
    Kononen, Mervi
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2008, 25 (06) : 367 - 372
  • [6] Evaluation of Changes in Preoperative Cortical Excitability by Navigated Transcranial Magnetic Stimulation in Patients With Brain Tumor
    Neville, Iuri Santana
    dos Santos, Alexandra Gomes
    Almeida, Cesar Cimonari
    Hayashi, Cintya Yukie
    Fontoura Solla, Davi Jorge
    Galhardoni, Ricardo
    de Andrade, Daniel Ciampi
    Brunoni, Andre Russowsky
    Teixeira, Manoel Jacobsen
    Paiva, Wellingson Silva
    FRONTIERS IN NEUROLOGY, 2021, 11
  • [7] Test-retest Reliability of Navigated Transcranial Magnetic Stimulation of the Motor Cortex
    Forster, Marie-Therese
    Limbart, Moritz
    Seifert, Volker
    Senft, Christian
    OPERATIVE NEUROSURGERY, 2014, 10 (01) : 51 - 55
  • [8] Safety and tolerability of navigated transcranial magnetic stimulation in a tumor patient with no bone flap
    Kandeel, Hussein
    Mirza, Asfand
    Lavrador, Jose Pedro
    Patel, Sabina
    Gullan, Richard
    Bhangoo, Ranjeev
    Vergani, Francesco
    Ashkan, Keyoumars
    CLINICAL NEUROPHYSIOLOGY, 2020, 131 (02) : 592 - 593
  • [9] Accuracy and precision of navigated transcranial magnetic stimulation
    Nieminen, Aino E.
    Nieminen, Jaakko O.
    Stenroos, Matti
    Novikov, Pavel
    Nazarova, Maria
    Vaalto, Selja
    Nikulin, Vadim
    Ilmoniemi, Risto J.
    JOURNAL OF NEURAL ENGINEERING, 2022, 19 (06)
  • [10] Preoperative Applications of Navigated Transcranial Magnetic Stimulation
    Haddad, Alexander F.
    Young, Jacob S.
    Berger, Mitchel S.
    Tarapore, Phiroz E.
    FRONTIERS IN NEUROLOGY, 2021, 11