Accuracy of the concentration of morphine infusions prepared for patients in a neonatal intensive care unit

被引:27
|
作者
Aguado-Lorenzo, Virginia [1 ]
Weeks, Kevin [2 ]
Tunstell, Paul [3 ]
Turnock, Karen [4 ]
Watts, Timothy [4 ]
Arenas-Lopez, Sara [5 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Dept Pharm, London, England
[2] Guys & St Thomas NHS Fdn Trust, Pharm QC Dept, London, England
[3] Guys & St Thomas NHS Fdn Trust, Pharm Asept Serv, London, England
[4] Guys & St Thomas NHS Fdn Trust, Evelina Childrens Hosp, Neonatal Intens Care Unit, London, England
[5] Guys & St Thomas NHS Fdn Trust, Pharm Evelina Childrens Hosp, London, England
关键词
ERRORS; REPRODUCIBILITY; VARIABILITY; MEDICATIONS; TECHNOLOGY; INJECTIONS;
D O I
10.1136/archdischild-2013-304522
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective To investigate the accuracy of morphine infusions prepared for neonates in relation to the label strength and to identify the differences in deviation between infusions made in neonatal intensive care unit (NICU) and those dispensed ready-to-use from pharmacy. Methods Unused portions of morphine solution for infusion were collected over a 6-weeks period and used to determine the concentration of the drug by high-performance liquid chromatography (HPLC). Results A total of 19.2% of infusions prepared by nurses in the ward and 7.8% prepared in the pharmacy were outside the limit required by the British Pharmacopoeia (+/- 7.5%). Moreover, a deviation in concentration of more than 20% was found in ward-prepared infusions, although this was caused by volume discrepancies of less than 0.2 mL. The frequency and magnitude of deviations found in infusions prepared in pharmacy was lower than in those prepared by NICU. The latter showed significantly higher number of out-of-specification samples (p=0.015); however, deviations from intended concentration occurred in both settings. Significant differences between pharmacy and NICU for volumes of less than 0.5 mL or for less than 1 mL were not identified probably due to small sample size, but statistical data show a trend for differences. Conclusions Current practice of preparation of infusions from strengths intended for older children and adults involves dilution of small volumes in a syringe and leads to inaccuracy in the final concentration of infusions for neonatal use. We propose the implementation of standard concentrations for this patient group to effectively eliminate these errors.
引用
收藏
页码:975 / 979
页数:5
相关论文
共 50 条
  • [1] Safety of Morphine in Nonintubated Infants in the Neonatal Intensive Care Unit
    Taddio, Anna
    Crosdale, Blondel
    Hogan, Mary-Ellen
    El Sayed, Manal F.
    Lee, Kyong-Soon
    Moore, Aideen M.
    Shah, Vibhuti
    [J]. CLINICAL JOURNAL OF PAIN, 2009, 25 (05): : 418 - 422
  • [2] Pharmacokinetics of dexmedetomidine infusions for patients in the intensive care unit
    RM Venn
    MD Karol
    RM Grounds
    [J]. Critical Care, 5 (Suppl 1):
  • [3] IMPACT OF RECONSTITUTION SOLVENT ON THE ACCURACY OF VANCOMYCIN SYRINGES PREPARED FOR INTRAVENOUS ADMINISTRATION IN A NEONATAL INTENSIVE CARE UNIT
    Foinard, A.
    Decaudin, B.
    Lannoy, D.
    Simon, N.
    Barthelemy, C.
    Storme, L.
    Odou, P.
    [J]. INTENSIVE CARE MEDICINE, 2013, 39 : S24 - S24
  • [4] THE RESOURCE IMPACT OF INTRODUCING MORPHINE CIVAS ON A NEONATAL INTENSIVE CARE UNIT
    Hoyle, E.
    Gates, D.
    Dewhurst, C.
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1802 - 1802
  • [5] Stressors in patients of neonatal intensive care unit
    da Vera, Samuel Oliveira
    de Oliveira Gouveia, Marcia Teles
    Barreto Dantas, Amanda Liicia
    da Rocha, Silvana Santiago
    [J]. REV RENE, 2018, 19
  • [6] Rocuronium infusions in the intensive care unit
    Hadbavny, A
    Rafkin, H
    Hoyt, J
    [J]. 9TH EUROPEAN CONGRESS ON INTENSIVE CARE MEDICINE, 1996, : 835 - 838
  • [7] Is it time to replace morphine with methadone for the treatment of pain in the neonatal intensive care unit?
    van den Anker, John
    [J]. PEDIATRIC RESEARCH, 2021, 89 (07) : 1608 - 1609
  • [8] MORPHINE USE AND ADVERSE-EFFECTS IN A NEONATAL INTENSIVE-CARE UNIT
    THOLL, DA
    WAGER, MS
    SAJOUS, CH
    MYERS, TF
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1994, 51 (22): : 2801 - 2803
  • [9] Is it time to replace morphine with methadone for the treatment of pain in the neonatal intensive care unit?
    John van den Anker
    [J]. Pediatric Research, 2021, 89 : 1608 - 1609
  • [10] EVALUATING AND IMPROVING CONTINUOUS MORPHINE WEANING PRACTICE IN THE NEONATAL INTENSIVE CARE UNIT
    Iacob, A.
    Meyer, R.
    Hayes, A.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 : A90 - A90