Validation of SimSET Monte Carlo Simulations of the Siemens Biograph mCT PET Scanner

被引:0
|
作者
Poon, Jonathan K. [1 ]
Dahlbom, Magnus L. [2 ]
Qi, Jinyi [1 ]
Cherry, Simon [1 ]
Badawi, Ramsey [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Calif Los Angeles, Dept Mol & Med Pharmacol, Los Angeles, CA 90095 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Introduction: SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner. Methods: SimSET is used to simulate positron emission and annihilation, model gamma ray photon absorption and scatter in objects and the LSO block detectors. In-house code is used for front-end detector pulse processing, electronic multiplexing, and coincidence generation. We use the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. Results: The SimSET model overestimates the singles, trues+scatter, randoms, and NEC count-rate curve by 11-22% compared to the experimental results, which compares favorably to previous validation studies of other PET scanners in the literature. For the spatial resolution test, the SimSET model underestimates the experimental results by 11-30%. This is expected as the detector model does not account for blurring due to light sharing and variations in light collection efficiency of the photodetectors. Variations of resolution with position in the field of view track those seen experimentally. Conclusions: The new block detector model in SimSET generates reasonable agreement with the experimental results.
引用
收藏
页码:2681 / 2684
页数:4
相关论文
共 50 条
  • [1] Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner
    Poon, Jonathan K.
    Dahlbom, Magnus L.
    Casey, Michael E.
    Qi, Jinyi
    Cherry, Simon R.
    Badawi, Ramsey D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : N35 - N45
  • [2] Validation of the Monte Carlo Simulation of a Siemens Biograph mCT PET
    Vazquez Canelas, L.
    Quintana Arnes, B.
    Montes Fuentes, C.
    Gutierrez Palmero, M. J.
    Tamayo Alonso, P.
    Blasco, J. M.
    BASIC CONCEPTS IN NUCLEAR PHYSICS: THEORY, EXPERIMENTS AND APPLICATIONS, 2016, 182 : 227 - 231
  • [3] Comparison of the portable CerePET positron emission tomography (PET) scanner with the Siemens Biograph mCT
    Bartlett, E.
    Lesanpezeshki, M.
    Anishchenko, S.
    Ogden, R.
    Mann, J.
    Beylin, D.
    Miller, J.
    Zanderigo, F.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2022, 42 (1_SUPPL): : 26 - 26
  • [4] Validation of a GATE model for the simulation of the Siemens biograph™ 6 PET scanner
    Gonias, P.
    Bertsekas, N.
    Karakatsanis, N.
    Saatsakis, G.
    Gaitanis, A.
    Nikolopoulos, D.
    Loudos, G.
    Papaspyrou, L.
    Sakellios, N.
    Tsantilas, X.
    Daskalakis, A.
    Liaparinos, P.
    Nikita, K.
    Louizi, A.
    Cavouras, D.
    Kandarakis, I.
    Panayiotakis, G. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 263 - 266
  • [5] Validation of GATE Monte Carlo simulations for Siemens PET/CT and PET/MR systems
    Kertesz, H.
    Renner, A.
    Rausch, I.
    Beyer, T.
    Cal-Gonzalez, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S298 - S299
  • [6] Evaluation of the HD and HD plus TOF reconstructions for Siemens' Biograph-mCT TOF PET scanner
    Cheng, Ju-Chieh
    Laforest, Richard
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4131 - 4134
  • [7] Quantitative comparison of PET performance—Siemens Biograph mCT and mMR
    Anna M. Karlberg
    Oddbjørn Sæther
    Live Eikenes
    Pål Erik Goa
    EJNMMI Physics, 3
  • [8] Factors influencing the PET image quality of the Siemens Biograph mCT
    Wierts, R.
    De Jong, J. R.
    Lazarenko, S. V.
    Segbers, M.
    Paans, A. M. J.
    Dierckx, R. A. J. O.
    Willemsen, A. T. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S335 - S335
  • [9] Comparison of Siemens Biograph Vision 600 and Biograph mCT PET-CT scanners
    Eberl, S.
    Verschuer, J.
    Waugh, A.
    Hughes, A.
    Fulham, M. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S273 - S273
  • [10] Evaluation of spatial resolution of Siemens Biograph mCT PET scanner for TOF and non-TOF reconstruction algorithms
    Suljic, A.
    Jensterle, L.
    Vidovic, B.
    Suhadolnik, M.
    Tomse, P.
    Skrk, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S508 - S508