Functional effects of an interpenetrating polymer network on articular cartilage mechanical properties

被引:14
|
作者
Makela, J. T. A. [1 ]
Cooper, B. G. [1 ,2 ]
Korhonen, R. K. [3 ,4 ]
Grinstaff, M. W. [2 ,5 ,6 ]
Snyder, B. D. [1 ,7 ]
机构
[1] Harvard Med Sch, Ctr Adv Orthopaed Studies, Beth Israel Deaconess Med Ctr, Boston, MA USA
[2] Boston Univ, Dept Chem, 590 Commonwealth Ave, Boston, MA 02215 USA
[3] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[4] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio, Finland
[5] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[6] Boston Univ, Dept Med, Boston, MA USA
[7] Harvard Med Sch, Boston Childrens Hosp, Dept Orthopaed Surg, Boston, MA USA
基金
美国国家科学基金会;
关键词
Articular cartilage; Osteoarthritis; Biomaterials; Biomechanics; Finite element analysis; ANTERIOR CRUCIATE LIGAMENT; INTERSTITIAL FLUID PRESSURIZATION; REINFORCED FINITE-ELEMENT; EXPERIMENTAL OSTEOARTHRITIS; PHYSICAL-PROPERTIES; STRESS-RELAXATION; SUPERFICIAL ZONE; LOAD SUPPORT; TRANSECTION; REGENERATION;
D O I
10.1016/j.joca.2018.01.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Depletion of glycosaminoglycans (GAGs) and degradation of collagen network are early hallmarks of osteoarthritis (OA). Currently, there are no chondroprotective therapies that mitigate the loss of GAGs or effectively restore the collagen network. Recently, a novel polymeric cartilage supplement was described that forms a charged interpenetrating polymer network (IPN) reconstituting the hydrophilic properties of the extracellular matrix (ECM). To investigate the mechanism by which this hydrophilic IPN improves articular cartilage material properties, a finite element (FE) model is used to evaluate the IPN's effect on the fibrillar collagen network, nonfibrillar matrix, and interstitial fluid flow. Methods: Bovine osteochondral plugs were degraded with chondroitinase ABC to selectively decrease GAG content. Samples were mechanically tested before and after IPN treatment using unconfined testing geometry and stress-relaxation protocol. Every measurement was modeled separately using a fibrilreinforced poroviscoelastic FE model. Measurement replication was achieved by optimizing the following model parameters: initial and strain-dependent fibril network modulus (E-f(0), E-f(epsilon), respectively), nonfibrillar matrix modulus (E-nf), initial permeability (k(0)) and strain-dependent permeability factor (M). Results: Based on the FE model results, treatment of native and GAG depleted cartilage with the hydrophilic IPN increases the ECM stiffness and impedes fluid flow. The IPN did not alter the stiffness of fibrillary network. Cartilage permeability and the strain-dependent permeability factor decreased with increasing IPN w/v%. Conclusions: The IPN reconstitutes cartilage material properties primarily by augmenting the hydrophilic ECM. This reinforcement of the solid phase also affects the fluid phase reestablishing low permeability. (c) 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 50 条
  • [1] Effects of Glycation on Mechanical Properties of Articular Cartilage
    Cicek, Ekrem
    ARCHIVES OF RHEUMATOLOGY, 2018, 33 (02) : 241 - 243
  • [2] Effects of freezing on the mechanical properties of articular cartilage
    Kennedy, Eric A.
    Tordonado, David S.
    Duma, Stefan M.
    Biomedical Sciences Instrumentation, Vol 43, 2007, 43 : 342 - 347
  • [3] Effects of radiopharmaceuticals on articular cartilage's mechanical properties
    Kuzu, Nihal
    Cicek, Ekrem
    NUKLEONIKA, 2019, 64 (02) : 71 - 74
  • [4] Effects of extracellular matrix on mechanical properties of articular cartilage
    Morita, Yusuke
    Tomita, Naohide
    Aoki, Hideyuki
    Takeda, Satoru
    Sakaguchi, Kazuhiko
    Ikeuchi, Ken
    Nippon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2003, 69 (01): : 84 - 89
  • [5] Effects of simulated microgravity on mechanical properties of rat articular cartilage
    Fan, Y.-B. (yubofan@buaa.edu.cn), 1600, Editorial Department of Journal of Shanghai Second Medical University (27):
  • [6] Study of altered mechanical properties of articular cartilage in relation to the collagen network
    Wu, J. P.
    Kirk, T. B.
    STRUCTURAL INTEGRITY AND FAILURE, 2008, 41-42 : 9 - 14
  • [7] Functional Nanogels as a Route to Interpenetrating Polymer Networks with Improved Mechanical Properties
    Gao, Guangzhe
    Wang, Xiance
    Chen, Mingtao
    Bowman, Christopher N.
    Stansbury, Jeffrey W.
    MACROMOLECULES, 2021, 54 (23) : 10657 - 10666
  • [8] MECHANICAL PROPERTIES OF ARTICULAR-CARTILAGE
    KEMPSON, GE
    JOURNAL OF PHYSIOLOGY-LONDON, 1972, 223 (01): : P23 - &
  • [9] Mechanical properties of PMMA/PEG TPE semi interpenetrating network polymer
    Jian, Xiao-Xia
    Xiao, Le-Qin
    Zhou, Wei-Liang
    Xu, Fu-Ming
    Guti Huojian Jishu/Journal of Solid Rocket Technology, 2008, 31 (04): : 377 - 380
  • [10] INTERPENETRATING POLYMER NETWORK OF POLYURETHANE AND UNSATURATED POLYESTER - MECHANICAL-PROPERTIES
    HSIEH, KH
    TSAI, JS
    CHANG, KW
    JOURNAL OF MATERIALS SCIENCE, 1991, 26 (21) : 5877 - 5882