Impact of charge trapping on the energy resolution of Ge detectors for rare-event physics searches

被引:10
|
作者
Mei, D-M [1 ]
Mukund, R. B. [2 ]
Wei, W-Z [1 ]
Panth, R. [1 ]
Liu, J. [1 ]
Mei, H. [1 ]
Li, Y-Y [1 ]
Acharya, P. [1 ]
Bhattarai, S. [1 ]
Kooi, K. [1 ]
Raut, M-S [1 ]
Sun, X-S [3 ]
Kirkvold, A. [1 ]
Dong, K-M [1 ,3 ]
Meng, X-H [1 ]
Wang, G-J [1 ]
Yang, G. [1 ]
机构
[1] Univ South Dakota, Dept Phys, Vermillion, SD 57069 USA
[2] Visva Bharati Univ, ISERC, Santini Ketan 731235, W Bengal, India
[3] Yangtze Univ, Sch Phys & Optoelect, Jingzhou 434023, Peoples R China
基金
美国国家科学基金会;
关键词
rare-event physics; charge trapping length; charge collection efficiency; absolute impurity level; LARGE-SCALE STRUCTURE; DARK-MATTER; DRIFT VELOCITY; FANO FACTOR; GERMANIUM; IONIZATION; CONTACT; ELECTRON; SILICON; LIMITS;
D O I
10.1088/1361-6471/ab9796
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Charge trapping degrades the energy resolution of germanium (Ge) detectors, which require increased experimental sensitivity in searching for dark matter and neutrinoless double-beta decay. We investigate the charge trapping processes utilizing nine planar detectors fabricated from USD-grown crystals with well-known net impurity levels. The charge collection efficiency as a function of charge trapping length is derived from the Shockley-Ramo theorem. Furthermore, we develop a model that correlates the energy resolution with the charge collection efficiency. This model is then applied to the experimental data. As a result, charge collection efficiency and charge trapping length are determined accordingly. Utilizing the Lax model (further developed by CDMS collaborators), the absolute impurity levels are determined for nine detectors. The knowledge of these parameters when combined with other traits such as the Fano factor serve as a reliable indicator of the intrinsic nature of charge trapping within the crystals. We demonstrate that electron trapping is more severe than hole trapping in a p-type detector and the charge collection efficiency depends on the absolute impurity level of the Ge crystal when an adequate bias voltage is applied to the detector. Negligible charge trapping is found when the absolute impurity level is less than 1.0 x 10(11)cm(-3)for collecting electrons and 2.0 x 10(11)cm(-3)for collecting holes.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Superconducting detectors for rare event searches in experimental astroparticle physics
    Kim, Yong-Hamb
    Lee, Sang-Jun
    Yang, Byeongsu
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2022, 35 (06):
  • [2] Phonon Wind Effects on Charge Collection in Cryogenic Ge Detectors for Rare Event Searches at Low Energies
    Broniatowski, A.
    Marnieros, S.
    Dumoulin, L.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2022, 209 (3-4) : 308 - 313
  • [3] Phonon Wind Effects on Charge Collection in Cryogenic Ge Detectors for Rare Event Searches at Low Energies
    A. Broniatowski
    S. Marnieros
    L. Dumoulin
    Journal of Low Temperature Physics, 2022, 209 : 308 - 313
  • [4] remoTES: a novel cryogenic detector for rare-event searches
    Bharadwaj, M. R.
    Angloher, G.
    Cababie, M.
    Dafinei, I
    Di Marco, N.
    Einfalt, L.
    Ferroni, F.
    Fichtinger, S.
    Filipponi, A.
    Frank, T.
    Friedl, M.
    Ge, Z.
    Heikinheimo, M.
    Hughes, M. N.
    Huitu, K.
    Kellermann, M.
    Maji, R.
    Mancuso, M.
    Pagnanini, L.
    Petricca, F.
    Pirro, S.
    Proebst, F.
    Profeta, G.
    Puiu, A.
    Reindl, F.
    Schaeffner, K.
    Schieck, J.
    Schmiedmayer, D.
    Schreiner, P.
    Schwertner, C.
    Shera, K.
    Stahlberg, M.
    Stendahl, A.
    Stuke, M.
    Tresca, C.
    Wagner, F.
    Yue, S.
    Zema, V
    Zhu, Y.
    XVIII INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS, 2024,
  • [5] Rare event searches with cryogenic detectors
    Mokina, Valentyna
    Schieck, Jochen
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2024, 382 (2266):
  • [6] Gram-scale cryogenic calorimeters for rare-event searches
    Strauss, R.
    Rothe, J.
    Angloher, G.
    Bento, A.
    Guetlein, A.
    Hauff, D.
    Kluck, H.
    Mancuso, M.
    Oberauer, L.
    Petricca, F.
    Proebst, F.
    Schieck, J.
    Schoenert, S.
    Seidel, W.
    Stodolsky, L.
    PHYSICAL REVIEW D, 2017, 96 (02)
  • [7] Diamond and SiC Detectors for Rare Event Searches
    Simchony, Aviv
    Smith, Zoe J.
    Young, Betty
    Brink, Paul
    Cabrera, Blas
    Cherry, Matthew
    Cudmore, Elspeth
    Hong, Ziqing
    Kagan, Harris
    Kenny, Christopher
    Ryan, James
    Kurinsky, Noah
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2024, 216 (1-2) : 363 - 370
  • [8] Ultra-low background mass spectrometry for rare-event searches
    Dobson, J.
    Ghag, C.
    Manenti, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 25 - 30
  • [9] Effect of SiO2 coating in bolometric Ge light detectors for rare event searches
    Beeman, J. W.
    Gentils, A.
    Giuliani, A.
    Mancuso, M.
    Pessina, G.
    Plantevin, O.
    Rusconi, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 709 : 22 - 28
  • [10] Characterization of bolometric light detectors for rare event searches
    Beeman, J. W.
    Bellini, F.
    Casali, N.
    Cardani, L.
    Dafinei, I.
    Di Domizio, S.
    Ferroni, F.
    Gironi, L.
    Nagorny, S.
    Orio, F.
    Pattavina, L.
    Pessina, G.
    Piperno, G.
    Pirro, S.
    Previtali, E.
    Rusconi, C.
    Tomei, C.
    Vignati, M.
    JOURNAL OF INSTRUMENTATION, 2013, 8