Image gradient L0-norm based PICCS for swinging multi-source CT reconstruction

被引:15
|
作者
Yu, Haijun [1 ,2 ,3 ]
Wu, Weiwen [1 ,2 ]
Chen, Peijun [1 ]
Gong, Changcheng [1 ,2 ]
Jiang, Junru [3 ]
Wang, Shaoyu [1 ,2 ]
Liu, Fenglin [1 ,2 ]
Yu, Hengyong [4 ]
机构
[1] Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Minist Educ, Chongqing 400044, Peoples R China
[3] Chongqing Univ, Coll Mech Engn, Chongqing 400044, Peoples R China
[4] Univ Massachusetts, Dept Elect & Comp Engn, Lowell, MA 01854 USA
来源
OPTICS EXPRESS | 2019年 / 27卷 / 04期
基金
中国国家自然科学基金;
关键词
COMPUTED-TOMOGRAPHY; SIMULATIONS;
D O I
10.1364/OE.27.005264
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dynamic computed tomography (CT) is usually employed to image motion objects, such as beating heart, corollary artery and cerebral perfusion. etc. Recently, to further improve the temporal resolution for aperiodic industrial process imaging, the swinging multi-source CT (SMCT) systems and the corresponding swinging multi-source prior image constrained compressed sensing (SM-PICCS) method were developed. Since the SM-PICCS uses the L-1-norm of image gradient, the edge structures in the reconstructed images are blurred and motion artifacts are still present. Inspired by the advantages in terms of image edge preservation and fine structure recovering, the L-0-norm of image gradient is incorporated into the prior image constrained compressed sensing, leading to an L-0-PICCS algorithm. The experimental results confirm that the L-0-PICCS outperforms the SM-PICCS in both visual inspection and quantitative analysis. 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:5264 / 5279
页数:16
相关论文
共 50 条
  • [1] Low-dose spectral CT reconstruction based on image-gradient L0-norm and adaptive spectral PICCS
    Wang, Shaoyu
    Wu, Weiwen
    Feng, Jian
    Liu, Fenglin
    Yu, Hengyong
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [2] Low-dose spectral CT reconstruction using image gradient l0-norm and tensor dictionary
    Wu, Weiwen
    Zhang, Yanbo
    Wang, Qian
    Liu, Fenglin
    Chen, Peijun
    Yu, Hengyong
    APPLIED MATHEMATICAL MODELLING, 2018, 63 : 538 - 557
  • [3] Limited-Angle X-Ray CT Reconstruction Using Image Gradient l0-Norm With Dictionary Learning
    Xu, Moran
    Hu, Dianlin
    Luo, Fulin
    Liu, Fenglin
    Wang, Shaoyu
    Wu, Weiwen
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (01) : 78 - 87
  • [4] An Algorithm of l1-Norm and l0-Norm Regularization Algorithm for CT Image Reconstruction from Limited Projection
    Li, Xiezhang
    Feng, Guocan
    Zhu, Jiehua
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2020, 2020 (2020)
  • [5] Image reconstruction from few views by l0-norm optimization
    Sun Yu-Li
    Tao Jin-Xu
    CHINESE PHYSICS B, 2014, 23 (07)
  • [6] Image reconstruction from few views by l0-norm optimization
    孙玉立
    陶进绪
    Chinese Physics B, 2014, (07) : 770 - 774
  • [7] l0DL: Joint Image Gradient l0-norm With Dictionary Learning for Limited-angle CT
    Xu, Moran
    Hu, Dianlin
    Wu, Weiwen
    ACM-BCB'19: PROCEEDINGS OF THE 10TH ACM INTERNATIONAL CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY AND HEALTH INFORMATICS, 2019, : 538 - 538
  • [8] Geophysical data sparse reconstruction based on L0-norm minimization
    Chen Guo-Xin
    Chen Sheng-Chang
    Wang Han-Chuang
    Zhang Bo
    APPLIED GEOPHYSICS, 2013, 10 (02) : 181 - 190
  • [9] Geophysical data sparse reconstruction based on L0-norm minimization
    Guo-Xin Chen
    Sheng-Chang Chen
    Han-Chuang Wang
    Bo Zhang
    Applied Geophysics, 2013, 10 : 181 - 190
  • [10] Adaptive continuation based smooth l0-norm approximation for compressed sensing MR image reconstruction
    Datta, Sumit
    Paul, Joseph Suresh
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (03)