Non-linear redundancy calibration

被引:27
|
作者
Marthi, Visweshwar Ram [1 ]
Chengalur, Jayaram [1 ]
机构
[1] Tata Inst Fundamental Res, Natl Ctr Radio Astrophys, Pune 411007, Maharashtra, India
关键词
methods: numerical; methods: statistical; techniques: interferometric; RADIO INTERFEROMETERS; SELF-CALIBRATION; DYNAMIC-RANGE; IMAGES;
D O I
10.1093/mnras/stt1902
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
For radio interferometric arrays with a sufficient number of redundant spacings the multiplicity of measurements of the same sky visibility can be used to determine both the antenna gains as well as the true visibilities. Many of the earlier approaches to this problem focused on linearized versions of the relation between the measured and the true visibilities. Here, we propose to use a standard non-linear minimization algorithm to solve for both the antenna gains as well as the true visibilities. We show through simulations done in the context of the ongoing upgrade to the Ooty Radio Telescope that the non-linear minimization algorithm is fast compared to the earlier approaches. Further, unlike the most straightforward linearized approach, which works with the logarithms of the visibilities and the gains, the non-linear minimization algorithm leads to unbiased solutions. Finally, we present error estimates for the estimated gains and visibilities. Monte Carlo simulations establish that the estimator is indeed statistically efficient, achieving the Cramer-Rao bound.
引用
收藏
页码:524 / 531
页数:8
相关论文
共 50 条
  • [1] Non-linear calibration
    Hinshaw, JV
    LC GC EUROPE, 2002, 15 (11) : 722 - +
  • [2] Linear or non-linear multivariate calibration models? That is the question
    Allegrini, Franco
    Olivieri, Alejandro C.
    ANALYTICA CHIMICA ACTA, 2022, 1226
  • [3] Comparison of linear and non-linear equations for univariate calibration
    Kirkup, L
    Mulholland, M
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) : 1 - 11
  • [4] Exploiting Non-Linear Redundancy for Neural Model Compression
    Shah, Muhammad A.
    Olivier, Raphael
    Raj, Bhiksha
    2020 25TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2021, : 9928 - 9935
  • [5] Research on a non-linear calibration method for dynamometer
    Chang, Qingbing
    Zhang, Jun
    Ren, Zongjin
    SENSOR REVIEW, 2020, 40 (02) : 167 - 173
  • [6] nCal: an R package for non-linear calibration
    Fong, Youyi
    Sebestyen, Krisztian
    Yu, Xuesong
    Gilbert, Peter
    Self, Steve
    BIOINFORMATICS, 2013, 29 (20) : 2653 - 2654
  • [7] PHASE CALIBRATION FOR NON-LINEAR NETWORK ANALYZERS
    Korotkov, K. S.
    Frolov, D. R.
    Levchenko, A. S.
    Kononenko, D. A.
    Polugodkin, R. S.
    2014 24TH INTERNATIONAL CRIMEAN CONFERENCE MICROWAVE & TELECOMMUNICATION TECHNOLOGY (CRIMICO), 2014, : 886 - 887
  • [8] A non-linear camera calibration with genetic algorithms
    Bouchouicha, M
    Ben Khelifa, M
    Puech, W
    SEVENTH INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND ITS APPLICATIONS, VOL 2, PROCEEDINGS, 2003, : 189 - 192
  • [9] Non-linear calibration models for near infrared spectroscopy
    Ni, Wangdong
    Norgaard, Lars
    Morup, Morten
    ANALYTICA CHIMICA ACTA, 2014, 813 : 1 - 14
  • [10] STANDARD ADDITION FOR STRONGLY NON-LINEAR CALIBRATION CURVES
    MULLER, MA
    OELSCHLAGER, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 307 (02): : 109 - 114