INTERNAL DOSIMETRY TOOL FOR THE IMPLEMENTATION AND USE OF NEW ICRP/OIR MODELS: A CAESIUM STUDY

被引:1
|
作者
Moraleda, Montse [1 ]
Sanchez-Leon, Guillermo [2 ]
Antonia Lopez, Maria [1 ]
机构
[1] CIEMAT, Avd Complutense 40, Madrid 28040, Spain
[2] Univ Salamanca, Campus Miguel de Unamuno, Salamanca 37007, Spain
关键词
D O I
10.1093/rpd/ncz307
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In case of accidental intake of radioactive material, the dose assessment requires information on the radionuclide distribution in the body. Measurements of retention or excretion are compared with model's predictions to estimate the intake. The reference models for internal dosimetry purposes are those proposed by ICRP and have been recently updated in the 'Occupational Intakes of Radionuclides (OIR)' series. This work focusses on the implementation of the new caesium model in a computer package, ICRP130Models (integrated in the toolbox BIOKMOD), together with new features aimed at estimating the intake and the dose from bioassay measurements. The software gives the best fitted intake and the committed effective dose, as well as the chi-squared test and the p-value as an indication of the goodness of the fit in the assessment process. The possibility to build the model as a function of a parameter allows the user to look for different options when fitting the bioassay measurements.
引用
收藏
页码:477 / 485
页数:9
相关论文
共 50 条
  • [1] Models of ICRP for internal dosimetry - Status and perspectives
    Nosske, D
    [J]. RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 253 - 259
  • [2] A COMPARISON OF THE USE OF ICRP2 AND ICRP30 INTERNAL DOSIMETRY MODELS IN A REPOSITORY SITE ANALYSIS
    RUNKLE, GE
    CRANWELL, RM
    [J]. HEALTH PHYSICS, 1982, 43 (01): : 143 - 143
  • [3] A computational study of the urinary excretion rates for 239Pu using new ICRP internal dosimetry models
    Singh, IS
    Sharma, RC
    Abani, MC
    [J]. RADIATION PROTECTION DOSIMETRY, 2003, 105 (1-4) : 361 - 364
  • [4] Review of the ICRP tritium and 14C internal dosimetry models and their implementation in the Genmod-PC code
    Richardson, RB
    Dunford, DW
    [J]. HEALTH PHYSICS, 2001, 81 (03): : 289 - 301
  • [5] Improving the reliability of internal dosimetry for uranium workers: Application of the ICRP/OIR uranium model to long-term occupational intakes
    Lopez, M. A.
    Sanchez-Leon, G.
    Hernandez, C.
    Moraleda, M.
    Rodriguez-Diaz, J. M.
    Sierra, I.
    Sierra, S.
    Garcia, D.
    [J]. RADIATION MEASUREMENTS, 2024, 176
  • [6] Voxel anthropomorphic models as a tool for internal dosimetry
    Petoussi-Henss, N
    Zankl, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) : 415 - 418
  • [7] IDAC-Bio, A Software for Internal Dosimetry Based on the New ICRP Biokinetic Models and Specific Absorbed Fractions
    Andersson, Martin
    Leggett, Richard W.
    Eckerman, Keith
    Almen, Anja
    Mattsson, Soren
    [J]. HEALTH PHYSICS, 2022, 123 (02): : 165 - 172
  • [8] Internal dose calculations with the new biokinetic models of the ICRP
    Silverman, I
    Shamai, Y
    Schlesinger, T
    Biran, T
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 86 (01) : 33 - 38
  • [9] COMPARISON OF OLD AND NEW ICRP MODELS FOR RESPIRATORY-TRACT DOSIMETRY
    BOECKER, BB
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 60 (04) : 331 - 336
  • [10] NEW DEVELOPMENTS IN INTERNAL DOSIMETRY MODELS
    Nosske, D.
    Blanchardon, E.
    Bolch, W. E.
    Breustedt, B.
    Eckerman, K. F.
    Giussani, A.
    Harrison, J. D.
    Klein, W.
    Leggett, R. W.
    Lopez, M. A.
    Luciani, A.
    Zankl, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 314 - 320