Reliability of three lumbar sagittal motion measurement methods: Surface inclinometers

被引:25
|
作者
Chen, SPC
Samo, DG
Chen, EH
Crampton, AR
Conrad, KM
Egan, L
Mitton, J
机构
[1] OMEGA,GLENVIEW,IL 60025
[2] UNIV ILLINOIS,COLL MED,CHICAGO,IL 60612
[3] UNIV ILLINOIS,SCH PUBL HLTH,CHICAGO,IL
[4] NORTHWESTERN UNIV,EVANSTON HOSP,EVANSTON,IL 60201
[5] NORTHWESTERN UNIV,DEPT MED,EVANSTON,IL
[6] NORTHWESTERN UNIV,DEPT RADIOL,EVANSTON,IL
关键词
D O I
10.1097/00043764-199703000-00011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Three surface methods for measuring lumbar sagittal motion (LSM) were tested for reliability, The three methods used were the Pleurimeter V double inclinometer, the carpenter double inclinometer, and the computerized single sensor inclinometer, In this study, 30 volunteers were examined independently by three occupational health professionals. Each volunteer rotated twice through three stations at which LSM was measured by each of the three methods. The intra- and interexaminer reliabilities in identifying the skin levels of T12 and S1 were acceptable, having intraclass correlation coefficients (ICC) greater than or equal to 0.75, With a single exception, all ICC values for the intraexaminer reliability of LSM measurements fell below 0.90 (a clinically desirable level). The interexaminer reliability was poor, with all ICC values below 0.75, The largest source of measurement error was attributable to the examiner and its associated factors. We concluded that the intra- and interexaminer reliabilities varied greatly, limiting the clinical usefulness of the three surface methods.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 50 条
  • [1] Validity of three lumbar sagittal motion measurement methods: Surface inclinometers compared with radiographs
    Samo, DG
    Chen, SPC
    Crampton, AR
    Chen, EH
    Conrad, KM
    Egan, L
    Mitton, J
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 39 (03) : 209 - 216
  • [2] MEASUREMENT OF LUMBAR SAGITTAL MOBILITY - A COMPARISON OF METHODS
    SALISBURY, PJ
    PORTER, RW
    [J]. SPINE, 1987, 12 (02) : 190 - 193
  • [3] Measurement of lumbar spine intervertebral motion in the sagittal plane using videofluoroscopy
    Harvey, Steven
    Hukins, David
    Smith, Francis
    Wardlaw, Douglas
    Kader, Deiary
    [J]. JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2016, 29 (03) : 445 - 457
  • [4] MOTION OF THE LUMBAR SPINE - RELIABILITY OF 2 MEASUREMENT TECHNIQUES
    DILLARD, J
    TRAFIMOW, J
    ANDERSSON, GBJ
    CRONIN, K
    [J]. SPINE, 1991, 16 (03) : 321 - 324
  • [5] VALIDITY AND RELIABILITY OF A NEW ELECTROGONIOMETER FOR MEASUREMENT OF SAGITTAL DORSO-LUMBAR MOVEMENTS
    PAQUET, N
    RICHARDS, CL
    MALOUIN, F
    DIONNE, JP
    COMEAU, F
    [J]. PHYSICAL THERAPY, 1988, 68 (05): : 826 - 826
  • [6] QUANTIFICATION OF LUMBAR FUNCTION .5. RELIABILITY OF RANGE-OF-MOTION MEASURES IN THE SAGITTAL PLANE AND AN INVIVO TORSO ROTATION MEASUREMENT TECHNIQUE
    KEELEY, J
    MAYER, TG
    COX, R
    GATCHEL, RJ
    SMITH, J
    MOONEY, V
    [J]. SPINE, 1986, 11 (01) : 31 - 35
  • [7] VARIANCE IN THE MEASUREMENT OF SAGITTAL LUMBAR SPINE RANGE OF MOTION AMONG EXAMINERS, SUBJECTS, AND INSTRUMENTS
    MAYER, RS
    CHEN, IH
    LAVENDER, SA
    TRAFIMOW, JH
    ANDERSSON, GBJ
    [J]. SPINE, 1995, 20 (13) : 1489 - 1493
  • [8] BACK SURFACE CURVATURE AND MEASUREMENT OF LUMBAR SPINAL MOTION
    STOKES, IAF
    BEVINS, TM
    LUNN, RA
    [J]. SPINE, 1987, 12 (04) : 355 - 361
  • [9] The influence of occupation on lumbar sagittal motion and posture
    Milosavljevic, S
    Milburn, PD
    Knox, BW
    [J]. ERGONOMICS, 2005, 48 (06) : 657 - 667
  • [10] Range of motion and lordosis of the lumbar spine - Reliability of measurement and normative values
    Ng, JKF
    Kippers, V
    Richardson, CA
    Parnianpour, M
    [J]. SPINE, 2001, 26 (01) : 53 - 60