Influence of Length of Occlusal Support on Masticatory Function of Free-End Removable Partial Dentures

被引:0
|
作者
Sanchez-Ayala, Alfonso [1 ]
Bovi Ambrosano, Glaucia Maria [2 ]
Matheus Rodrigues Garcia, Renata Cunha [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, BR-13414903 Piracicaba, SP, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Social Dent, BR-13414903 Piracicaba, SP, Brazil
关键词
ORTHOGNATHIC SURGERY PATIENTS; CHEWING SIDE PREFERENCE; ARTIFICIAL TEST FOODS; TEMPOROMANDIBULAR-JOINT; MANDIBULAR MOVEMENT; PERFORMANCE; COMMINUTION; EFFICIENCY; SELECTION; BREAKAGE;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to determine the influence of occlusal support length (OSL) of free-end removable partial dentures (RPDs) on masticatory function. Materials and Methods: Twenty-three subjects (mean age: 55.2 +/- 8.4 years) who were edentulous in the maxilla and classified as Kennedy Class I in the mandible were selected. Subjects received new maxillary complete dentures and mandibular RPDs. Five OSL conditions were determined by RPD artificial tooth wear: full occlusal support (L1, control), OSL to first molar (L2), OSL to second premolar (L3), OSL to first premolar (L4), and absence of occlusal support (L5). Masticatory performance and efficiency were evaluated using the sieve method. Chewing rate was defined as the number of masticatory cycles per minute. Bolus selection opportunities and bolus breakage function were evaluated using the one-chew method. Qualitative and quantitative measurements of masticatory cycle patterns were recorded kinesiographically. Data were analyzed using repeated-measures analysis of variance and Friedman and Fisher exact tests (alpha = .05). Results: Masticatory performance and efficiency decreased (P < .05) from L1 (5.46 +/- 0.64 mm and 51.21% +/- 19.44%, respectively) to L5 (6.24 +/- 0.44 mm and 24.50% +/- 15.98%, respectively). Chewing rate was higher for L4 than L1 (P < .05). Bolus selection chances and bolus breakage function decreased as OSL was reduced (P < .05); however, there were no differences in masticatory cycle pattern among the OSL conditions (P > .05). Conclusion: Reduction of OSL altered masticatory function, thereby decreasing masticatory performance and efficiency resulting from a lower capacity to select and break down food. Int J Prosthodont 2012;25:472-479.
引用
收藏
页码:472 / 479
页数:8
相关论文
共 50 条
  • [1] Influence of Length of Occlusal Support on Masticatory Function of Free-End Removable Partial Dentures: Short-Term Adaptation
    Sanchez-Ayala, Alfonso
    Simek Vega Goncalves, Thais Marques
    Bovi Ambrosano, Glaucia Maria
    Matheus Rodrigues Garcia, Renata Cunha
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (04): : 313 - 318
  • [2] REMOVABLE PARTIAL DENTURES - PROBLEM OF FREE-END DENTURE BASES
    NAIRN, RI
    JOURNAL OF PROSTHETIC DENTISTRY, 1966, 16 (03): : 522 - &
  • [3] Implant retainers for free-end removable partial dentures affect mastication and nutrient intake
    Campos, Camila Heitor
    Vega Goncalves, Thais Marques Simek
    Matheus Rodrigues Garcia, Renata Cunha
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 957 - 961
  • [4] OCCLUSAL RELATIONSHIPS FOR REMOVABLE PARTIAL DENTURES
    MCCRACKEN, WL
    JOURNAL OF PROSTHETIC DENTISTRY, 1962, 12 (02): : 311 - &
  • [5] FREE-END PONTICS USED ON FIXED PARTIAL DENTURES
    SCHWEITZER, JM
    SCHWEITZER, RD
    SCHWEITZ.J
    JOURNAL OF PROSTHETIC DENTISTRY, 1968, 20 (02): : 120 - +
  • [6] OCCLUSAL REQUIREMENTS FOR REMOVABLE PARTIAL DENTURES
    COLMAN, AJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1967, 17 (02): : 155 - &
  • [7] A NEW FREE-END REMOVABLE PARTIAL DENTURE DESIGN
    NAVAS, MTR
    DELCAMPO, ML
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 70 (02): : 176 - 179
  • [8] Influence of working side contacts on masticatory function for mandibular distal extension removable partial dentures
    Sueda, S
    Fueki, K
    Sato, S
    Sato, H
    Shiozaki, T
    Kato, M
    Ohyama, T
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (03) : 301 - 306
  • [9] Impact of implant support on mandibular free-end base removable partial denture: theoretical study
    Oh, Won-suk
    Oh, Tae-Ju
    Park, Ju-mi
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : E87 - E90
  • [10] Mechanical Effect of an Implant Under Denture Base in Implant-Supported Distal Free-End Removable Partial Dentures
    Murashima, Naomichi
    Takayama, Yoshiyuki
    Nogawa, Toshifumi
    Yokoyama, Atsuro
    Sakaguchi, Kiwamu
    DENTISTRY JOURNAL, 2024, 12 (11)