Use of ceramic-on-ceramic bearing in total hip arthroplasty for posttraumatic arthritis of the hip

被引:3
|
作者
Lee, Young-Kyun [1 ]
Kim, Ki-Choul [2 ]
Kim, Jin-Woo [3 ]
Ha, Joo Hyung [3 ]
Yoon, Byung-Ho [4 ]
Ha, Yong-Chan [5 ]
Koo, Kyung-Hoi [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Orthopaed Surg, Seongnam, South Korea
[2] Dankook Univ Hosp, Dept Orthopaed Surg, Cheonan, South Korea
[3] Eulji Univ, Coll Med, Eulji Med Ctr, Dept Orthopaed Surg, 68 Hangeulbiseok Ro, Seoul, South Korea
[4] Inje Univ, Coll Med, Seoul Paik Hosp, Dept Orthopaed Surg, Seoul, South Korea
[5] Chung Ang Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
关键词
ceramic-on-ceramic; posttraumatic arthritis; total hip arthroplasty; ACETABULAR FRACTURES; FOLLOW-UP;
D O I
10.1177/2309499019836378
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: We aimed to evaluate (1) the intraoperative parameters, (2) cup position, (3) complications, (4) long-term results, and (5) the survivorship of cementless total hip arthroplastys (THAs) with use of ceramic bearings in patients with a history of acetabular fracture. Methods: We compared 57 THAs in patients, who were treated due to previous acetabular fracture (posttraumatic group), with 57 propensity score-matched THAs in patients, who were operated due to femoral head osteonecrosis (osteonecrotic group), at a minimum of 5-year follow-up. Results: The operation time was longer (p = 0.008), and the volume of transfusion was larger (p = 0.0.23) in the posttraumatic group. The cup abduction (39.4 degrees +/- 6.0 degrees vs. 39.7 degrees +/- 4.8 degrees) and anteversion (24.7 degrees +/- 8.0 degrees vs. 26.7 degrees +/- 7.7 degrees) were similar between the two groups. There was one dislocation in the posttraumatic group. There was no ceramic fracture in either group. One posttraumatic patient underwent excision of exuberant heterotrophic ossification at 3 years after the arthroplasty. The mean University of California, Los Angeles activity improved from 3.6 to 4.9 points in the posttraumatic group and 3.5 to 5.2 points in the osteonecrotic group. All acetabular cups and femoral stems had bone-ingrown stability. When reoperation for any reason was used as the end point, the 10-year survival rate was 98.3% (95% CI: 95.0-100) in the posttraumatic group and 100% in the osteonecrotic group. Conclusion: In our study, posttraumatic patients had longer operation time and larger volume of transfusion than osteonecrotic patients. However, medium-term results and survivorship were similar with those of osteonecrotic patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Ceramic-on-Ceramic Total Hip Arthroplasty
    Greene, Joseph W.
    Malkani, Arthur L.
    Kolisek, Frank R.
    Jessup, Nenette M.
    Baker, Dale L.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (06): : 15 - 18
  • [2] The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip Arthroplasty
    Jarrett, Christopher A.
    Ranawat, Amar S.
    Bruzzone, Matteo
    Blum, Yossef C.
    Rodriguez, Jose A.
    Ranawat, Chitranjan S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06): : 1344 - 1349
  • [3] Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty
    Wu, Guo-Liang
    Zhu, Wei
    Zhao, Yan
    Ma, Qi
    Weng, Xi-Sheng
    CHINESE MEDICAL JOURNAL, 2016, 129 (15) : 1861 - 1866
  • [4] Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty
    Guo-Liang Wu
    Wei Zhu
    Yan Zhao
    Qi Ma
    Xi-Sheng Weng
    中华医学杂志(英文版), 2016, 129 (15) : 1861 - 1866
  • [5] Ceramic-on-ceramic bearings in total hip arthroplasty
    Bierbaum, BE
    Nairus, J
    Kuesis, D
    Morrison, JC
    Ward, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) : 158 - 163
  • [6] Ceramic-on-Ceramic Total Hip Arthroplasty: Update
    Capello, William N.
    D'Antonio, James A.
    Feinberg, Judy R.
    Manley, Michael T.
    Naughton, Marybetb
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 39 - 43
  • [7] Ceramic-on-ceramic implants in total hip arthroplasty
    Colwell, C
    D'Antonio, JA
    Capello, WN
    Hardwick, ME
    BIOCERAMICS 17, 2005, 284-286 : 1003 - 1006
  • [8] Ceramic-on-Ceramic Versus Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
    Hu, Dongcai
    Yang, Xiao
    Tan, Yang
    Alaidaros, Mohammed
    Chen, Liaobin
    ORTHOPEDICS, 2015, 38 (04) : E331 - E338
  • [9] Pseudotumor from ceramic-on-ceramic total hip arthroplasty
    Ciatti, Corrado
    Maniscalco, Pietro
    Bosio, Silvia
    Pagliarello, Calogero Puma
    Bianchi, Giuseppe
    Quattrini, Fabrizio
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2024, 116
  • [10] Squeaking sound in total hip arthroplasty using ceramic-on-ceramic bearing surfaces
    Ki, Sung-Chan
    Kim, Byung-Hak
    Ryu, Ji-Hoon
    Yoon, Dae-Hyun
    Chung, Young-Yool
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (01) : 21 - 25