Sentinel lymph node biopsy in patients with multicentric/multifocal breast cancer: low false-negative rate and lack of axillary recurrence

被引:9
|
作者
Hotwitt, Dana M. [1 ]
Gillanders, William E. [1 ]
Aft, Rebecca L. [1 ,2 ]
Eberlein, Timothy J. [1 ]
Margenthaler, Julie A. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Surg, St Louis, MO 63110 USA
[2] John Cochran Vet Hosp, Dept Surg, St Louis, MO USA
来源
AMERICAN JOURNAL OF SURGERY | 2008年 / 196卷 / 04期
关键词
Breast Cancer; Multicentric; Multifocal; Sentinel lymph node biopsy;
D O I
10.1016/j.amjsurg.2008.06.009
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: Accuracy of sentinel lymph node biopsy (SLNB) and rate of axillary recurrence in multicentric/multifocal (MC/MF) breast cancer are reported. METHODS: From 1999 to 2006, 93 patients with MC/MF breast cancer underwent SLNB; 41 underwent axillary lymph node dissection regardless of SLN pathology (group 1), and 5:1 underwent axillary lymph node dissection only if an SLN was positive (group 2). Patient demographics, SLN techniques, and pathology were recorded. RESULTS: There were no differences between the 2 groups with respect to patient aged tumor size, grade, stage, and histology; or method of SLN detection. The incidence of axillary metastasis was greater in group 1 patients (68%) compared with group 2 patients (12%) (P < .01). In group 1, the sensitivity and specificity of SLNB were 93% and 100%, respectively, with a false-negative rate of 7%. None of the 52 patients in group 2 experienced axillary recurrence (median follow-up 4.8 years). CONCLUSIONS: The accuracy of SLNB in MC/MF breast cancer is comparable with that observed in unifocal breast cancer. Despite a lower rate of SLN positivity in patients undergoing SLNB only, axillary recurrence was not observed. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:562 / 565
页数:4
相关论文
共 50 条
  • [1] Axillary Recurrence Rate in Patients with Breast Cancer and Negative Sentinel Lymph Node Biopsy
    Sajjadi, Samaneh
    Rahimi, Hossein
    Alamdaran, Ali
    Forghani, Mohammad Naser
    Sadeghi, Ramin
    Abdollahi, Abbas
    INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2018, 11 (08)
  • [2] Factors associated with false-negative rate of sentinel lymph node biopsy in breast cancer patients
    Hazel Chua, Joyce
    Chan, Valerie
    Ang, Samuel
    Chua, Derrick
    Torillo, Maila
    Tan, Benito
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 : 417 - 417
  • [3] Is axillary lymph node dissection necessary in breast cancer patients with mastectomy and false-negative frozen section in sentinel lymph node biopsy?
    Si, J.
    ANNALS OF ONCOLOGY, 2020, 31 : S326 - S326
  • [4] Intraoperative palpation for clinically suspicious axillary sentinel lymph nodes reduces the false-negative rate of sentinel lymph node biopsy in breast cancer
    Carmon, M
    Olsha, O
    Rivkin, L
    Spira, RM
    Golomb, E
    BREAST JOURNAL, 2006, 12 (03): : 199 - 201
  • [5] Axillary recurrence rate in breast cancer patients with negative sentinel lymph node
    Snoj, M
    Bracko, M
    Zagar, I
    CROATIAN MEDICAL JOURNAL, 2005, 46 (03) : 377 - 381
  • [6] Axillary recurrence in breast cancer patients after a negative sentinel lymph node biopsy
    Benson, J. R.
    Wishart, G. C.
    Forouhi, P.
    Jones, B.
    Pinder, S. E.
    EJC SUPPLEMENTS, 2007, 5 (03): : 21 - 22
  • [7] Axillary Recurrence in Breast Cancer Patients Following Negative Sentinel Lymph Node Biopsy
    Clayton, G.
    Teo, K.
    Borg, N.
    Wishart, G. C.
    Forouhi, P.
    Benson, J. R.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S223 - S223
  • [8] Axillary Lymph Node Dissection Can Be Omitted in Breast Cancer Patients With Mastectomy and False-Negative Frozen Section in Sentinel Lymph Node Biopsy
    Si, Jing
    Guo, Rong
    Pan, Huan
    Lu, Xiang
    Guo, Zhiqin
    Han, Chao
    Xue, Li
    Xing, Dan
    Wu, Wanxin
    Chen, Caiping
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [9] Axillary recurrence rate after negative sentinel lymph node biopsy for invasive breast cancer
    ten Brinke, J.
    Klaase, J. M.
    Holzik, M. F. Lutke
    EJC SUPPLEMENTS, 2010, 8 (03): : 150 - 151
  • [10] False-negative frozen section of sentinel lymph node biopsy for breast cancer
    Holck, S
    Galatius, H
    Engel, U
    Wagner, F
    Hoffmann, J
    BREAST, 2004, 13 (01): : 42 - 48