Cochlear Implant for Tinnitus and Hyperacusis: A Case Report

被引:0
|
作者
Artiles Cabrera, Ovidio [1 ]
Rodriguez Martinez, Carina [1 ]
Falcon Gonzalez, Juan Carlos [1 ]
Ramos Macias, Angel [1 ]
机构
[1] Complejo Hosp Univ Insular Materno Infantil Gran, Las Palmas Gran Canaria, Spain
来源
关键词
D O I
暂无
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Tinnitus and hyperacusis are new challenged emergent indications of cochlear implantation. Some reports have demonstrated a suppression of tinnitus as a side effect after implantation. We describe the case of a 57-year-old man suffering from severe tinnitus and hyperacusis. Several years after onset of symptoms cochlear implantation was performed, which resulted in a progressive decrease of tinnitus and hyperacusis.
引用
收藏
页码:250 / 256
页数:7
相关论文
共 50 条
  • [1] COCHLEAR IMPLANT FOR TINNITUS - CASE-REPORTS
    THEDINGER, B
    HOUSE, WF
    EDGERTON, BJ
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1985, 94 (01): : 10 - 13
  • [2] Cochlear implant and tinnitus
    Olze, Heidi
    Vater, Jana
    Groeschel, Moritz
    Szczepek, Agnieszka J.
    HNO, 2023, 71 (11) : 693 - 701
  • [3] The cochlear implant as a tinnitus treatment
    Valles-Varela, Hector
    Royo-Lopez, Juan
    Carmen-Samperiz, Luis
    Sebastian-Cortes, Jose M.
    Alfonso-Collado, Ignacio
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2013, 64 (04): : 253 - 257
  • [4] Cochlear implant in tinnitus management
    Bahmad, Fayez
    Carasek, Natalia
    Lamounier, Pauliana
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2023, 31 (02): : 155 - 157
  • [5] TINNITUS AND HYPERACUSIS
    STOCKMANN, U
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 107 (25) : 998 - 998
  • [6] One-Year Results for Patients with Unilateral Hearing Loss and Accompanying Severe Tinnitus and Hyperacusis Treated with a Cochlear Implant
    Ramos Macias, Angel
    Carlos Falcon-Gonzalez, Juan
    Manrique Rodriguez, Manuel
    Morera Perez, Constantino
    Garcia-Ibanez, Luis
    Cenjor Espanol, Carlos
    Coudert-Koall, Chrystelle
    Killian, Matthijs
    AUDIOLOGY AND NEURO-OTOLOGY, 2018, 23 (01) : 8 - 19
  • [7] TINNITUS AND HYPERACUSIS
    FLEISCHER, K
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 107 (16) : 636 - 637
  • [8] Is noise-induced cochlear neuropathy key to the generation of hyperacusis or tinnitus?
    Hickox, Ann E.
    Liberman, M. Charles
    JOURNAL OF NEUROPHYSIOLOGY, 2014, 111 (03) : 552 - 564
  • [9] Effects of Tinnitus on Cochlear Implant Programming
    Pierzycki, Robert H.
    Corner, Charlotte
    Fielden, Claire A.
    Kitterick, Padraig T.
    TRENDS IN HEARING, 2019, 23
  • [10] Tinnitus suppression in cochlear implant patients
    Ito, J