EFFECT OF THERMAL STORAGE ON THE COOLING CAPACITY OF AMBIENT SOURCES

被引:0
|
作者
Robinson, Brian S. [1 ]
Sharp, M. Keith [1 ]
机构
[1] Univ Louisville, Louisville, KY 40292 USA
关键词
VENTILATION; BUILDINGS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ambient sources, including ambient air at dry-bulb and wet-bulb temperature, ground temperature and night sky temperature, were evaluated for their potential to provide space cooling in locations across the U.S. While ground temperature is constant beyond a certain depth, the other sources have fluctuating temperatures, which present intermittent potentials for cooling. Simultaneously, cooling demands also fluctuate with outdoor temperature. Thermal storage can bridge intervals of time during which cooling is needed in the building, but ambient source temperature is too high to provide cooling. The duration of these intervals and the thermal storage capacity required to meet cooling needs based on ambient source potential prior to the interval were quantified for all eleven climate zones across the continental U.S using TMY3 weather data. The thermal storage capacity required to meet the entire annual cooling load is dictated by the span of time without ambient source cooling potential that has the greatest ratio of cooling load to ambient source cooling potential prior to the interval. This maximum thermal storage capacity, normalized by building overall loss coefficient, (this ratio has units of time) was one day or less for night sky temperature for all but the three warmest climates. This ratio was one day or less for wet-bulb temperature for four locations, and for dry-bulb temperature for only two locations. Ground temperature provided continuous cooling potential in all but the three warmest climates, where ground temperature was warmer than the indoor comfort temperature. Because the maximum thermal storage capacity was determined in most climates by uncommon and infrequent coincidence of high cooling demand and low ambient source cooling potential, smaller thermal storage provided substantial cooling capacity in most cases. For instance, ten percent of the maximum supplied 99% of the cooling load for the dry-bulb ambient air source in Albuquerque, and 0.1% of the maximum served over 90% of the cooling load with night sky radiation in New Orleans and Phoenix. While considerable development of hardware and control algorithms to utilize ambient sources for space cooling has occurred, this study shows the potential of these sources to further reduce demands for conventional energy for space cooling across a wide range of climates.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] US space cooling potentials for ambient sources with thermal energy storage
    Robinson, Brian S.
    Dorwart, Jordan
    Sharp, M. Keith
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2015, 36 (06) : 268 - 281
  • [2] DETAILS STUDY OF AMBIENT WIND EFFECT ON HEAT DISSIPATION CAPACITY OF THERMAL-POWERPLANT DRY COOLING-TOWERS
    Darbandi, Masoud
    Behrouzifar, Ali
    Mirhashemi, Ahmad
    Salemkar, Hossein
    Schneider, Gerry E.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1A: SYMPOSIA, 2014,
  • [3] Effect Mechanism of Ambient Air Parameters on the Thermal Performance for Cooling Towers
    Zhang, Lei
    Zhou, Jun
    Zuo, Simeng
    An, Guangyao
    Lang, Jinhua
    Yuan, Wei
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (01)
  • [4] Energetic, environmental and economic aspects of thermal energy storage systems for cooling capacity
    Dincer, I
    Rosen, MA
    APPLIED THERMAL ENGINEERING, 2001, 21 (11) : 1105 - 1117
  • [5] Study on the frost thermal effect on cooling coils of cold storage
    Zhuang, YM
    Ye, MP
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 133 - 138
  • [6] Effect of encapsulated ice thermal storage system on cooling cost for a hypermarket
    Erdemir, Dogan
    Altuntop, Necdet
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (09) : 3091 - 3101
  • [7] Effect of Cooling Storage Capacity on the Transient Characteristics of the Vapor Cooled Shield for Liquid Hydrogen Storage Tank
    Jiang, Wenbing
    Hu, Cong
    Sun, Peijie
    Li, Peng
    Huang, Yonghua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (05): : 1161 - 1168
  • [8] SPACE COOLING POTENTIALS FOR AMBIENT ENERGY SOURCES ACROSS THE US
    Robinson, Brian S.
    Sharp, M. Keith
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 147 - 152
  • [9] Effect of thermal storage performance of concrete radiant cooling room on indoor temperature
    辛亚娟
    王志强
    田喆
    JournalofCentralSouthUniversity, 2012, 19 (03) : 709 - 714
  • [10] Effect of thermal storage performance of concrete radiant cooling room on indoor temperature
    Xin Ya-juan
    Wang Zhi-qiang
    Tian Zhe
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2012, 19 (03): : 709 - 714