A DNA miniarray system for simultaneous visual detection of porcine circovirus type 1 (PCV1) and 2 (PCV2) in pigs
被引:8
|
作者:
An, D. J.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Vet Res & Quarantine Serv, Anyang 430824, Kyunggi Do, South KoreaSeoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
An, D. J.
[4
]
Song, D. S.
论文数: 0引用数: 0
h-index: 0
机构:
Green Cross Vet Prod, Res Unit, Yongin 449903, South KoreaSeoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
Song, D. S.
[3
]
Park, J. Y.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Vet Res & Quarantine Serv, Anyang 430824, Kyunggi Do, South KoreaSeoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
Park, J. Y.
[4
]
Park, B. K.
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
Seoul Natl Univ, Program Vet Sci BK21, Seoul 151742, South KoreaSeoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
Park, B. K.
[1
,2
]
机构:
[1] Seoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
[2] Seoul Natl Univ, Program Vet Sci BK21, Seoul 151742, South Korea
[3] Green Cross Vet Prod, Res Unit, Yongin 449903, South Korea
[4] Natl Vet Res & Quarantine Serv, Anyang 430824, Kyunggi Do, South Korea
A miniarray system was developed for the simultaneous detection of porcine circovirus type 1 (PCV1) and type 2 (PCV2) in pigs. The system consists of a polymerase chain reaction (PCR) step to amplify target viral DNA, followed by detection of the amplified DNA using a membrane-anchored probe array and an avidin-alkaline phosphatase (Av-AP) indicator system. The lower limit of detection of PCV using the miniarray was 10(1.9) tissue culture infectious dose 50 (TCID50)/ml and 10(2.08)TCID(50)/ml for PCV1 and PCV2, respectively, and 100 viral copies/mu l for both PCV1 and PCV2. We validated the miniarray system using 141 lymph node specimens from pigs with suspected postweaning multisystemic wasting syndrome or porcine dermatitis and nephropathy syndrome. Of the 141 samples evaluated, 55 were identified as positive for PCV by the miniarray. Relative to in situ hybridization, the sensitivity and specificity of the miniarray was 100% and 98.9%, respectively. In contrast to other microarray systems, the miniarray does not require a DNA chip reader, since the results can be determined by visual inspection of colorized spots on a nylon membrane. This system represents an effective alternative method for the differential detection of PCV1 and PCV2 in pigs, as well as the maintenance of PCV-free cell lines and pre-screening of commercial vaccines for possible contamination.
机构:Virginia Polytech Inst & State Univ, Coll Vet Med, Ctr Mol Med & Infect Dis, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USA
Fenaux, M
Opriessnig, T
论文数: 0引用数: 0
h-index: 0
机构:Virginia Polytech Inst & State Univ, Coll Vet Med, Ctr Mol Med & Infect Dis, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USA
Opriessnig, T
Halbur, PG
论文数: 0引用数: 0
h-index: 0
机构:Virginia Polytech Inst & State Univ, Coll Vet Med, Ctr Mol Med & Infect Dis, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USA
Halbur, PG
Elvinger, F
论文数: 0引用数: 0
h-index: 0
机构:Virginia Polytech Inst & State Univ, Coll Vet Med, Ctr Mol Med & Infect Dis, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USA
Elvinger, F
Meng, XJ
论文数: 0引用数: 0
h-index: 0
机构:
Virginia Polytech Inst & State Univ, Coll Vet Med, Ctr Mol Med & Infect Dis, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USAVirginia Polytech Inst & State Univ, Coll Vet Med, Ctr Mol Med & Infect Dis, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USA