Feasibility of sparing lung and other thoracic structures with intensity-modulated radiotherapy for non-small-cell lung cancer

被引:163
|
作者
Liu, HH
Wang, XC
Dong, L
Wu, QW
Liao, ZX
Stevens, CW
Guerrero, TM
Komaki, R
Cox, JD
Mohan, R
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[2] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA USA
关键词
intensity-modulated radiotherapy; non-small-cell lung cancer; integral dose; low-dose volumes; lung toxicity;
D O I
10.1016/j.ijrobp.2003.09.085
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the possibility of using intensity-modulated radiotherapy (IMRT) to reduce the irradiated volumes of the normal lung and other critical structures in the treatment of non-small-cell lung cancer (NSCLC) and to investigate the effect of IMRT on the potential of spreading low doses to large volumes of normal tissues in such treatment. Methods and Materials: A retrospective treatment planning study was performed to compare IMRT and conventional three-dimensional conformal radiation therapy (3D-CRT) for 10 NSCLC patients (Stage I-IIIB). In the IMRT plans, three to nine coplanar beams were designed to treat 95% of the planning target volume with 63 Gy and to minimize the volumes of the normal lung, esophagus, heart, and spinal cord irradiated above their tolerance doses. The two types of plans were compared with respect to the planning target volume coverage, dose-volume histograms, and other dosimetric indexes of the normal structures. Results: Comparing the nine-beam IMRT plan with the 3D-CRT plan, the percentage of lung volume that received >20 Gy and the mean lung dose were reduced for all cases, with a median reduction of 8% and 2 Gy, respectively. An additional reduction of the >5-Gy volume and >10-Gy volume for the lung and thoracic tissue was more difficult with IMRT, although still possible using fewer beams in IMRT. The integral dose to the entire thorax was equivalent and even reduced for 8 of 10 cases using IMRT. Conclusion: It is possible to reduce the volumes of low doses (such as the >10-Gy volume and >20-Gy volume) for thoracic normal tissues using IMRT. The increased integral dose and low-dose volumes can be avoided for IMRT if such concerns are addressed carefully in the inverse planning process and with optimization of the IMRT beam configuration. (C) 2004 Elsevier Inc.
引用
收藏
页码:1268 / 1279
页数:12
相关论文
共 50 条
  • [1] Hypofractionated Intensity-Modulated Radiotherapy for Patients With Non-Small-Cell Lung Cancer
    Pollom, Erqi L.
    Qian, Yushen
    Durkee, Ben Y.
    von Eyben, Rie
    Maxim, Peter G.
    Shultz, David B.
    Gensheimer, Michael
    Diehn, Maximilian
    Loo, Billy W., Jr.
    CLINICAL LUNG CANCER, 2016, 17 (06) : 588 - 594
  • [2] INTENSITY-MODULATED STEREOTACTIC BODY RADIOTHERAPY FOR STAGE I NON-SMALL-CELL LUNG CANCER
    Kim, M.
    Kim, E.
    Min, C.
    Yeo, S.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S7 - S7
  • [3] An investigation of the feasibility of sparing lung and other thoracic organs using IMRT for treating non-small-cell lung cancer
    Liu, H
    Wang, X
    Dong, L
    Wu, Q
    Zhang, X
    Tu, S
    Mohan, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1485 - 1485
  • [4] Intensity-Modulated Radiotherapy in Treatment of Small Cell Lung Cancer
    Singh, Charu
    Gupta, Shivani
    JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S787 - S787
  • [5] Preserving functional lung using perfusion imaging and intensity-modulated radiotherapy for advanced-stage non-small-cell lung cancer
    Shioyama, Y.
    Jang, S.
    Liu, H. H.
    Guerrero, T.
    Wang, X.
    Gayed, I. W.
    Erwin, W. D.
    Liao, Z.
    Chang, J. Y.
    Komaki, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S481 - S481
  • [6] Dose and volume reduction for normal lung using intensity-modulated radiotherapy for advanced-stage non-small-cell lung cancer
    Murshed, H
    Liu, HH
    Liao, ZX
    Barker, JL
    Wang, XC
    Tucker, SL
    Chandra, A
    Guerrero, T
    Stevens, C
    Change, JY
    Jeter, M
    Cox, JD
    Komaki, R
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04): : 1258 - 1267
  • [7] Dose heterogeneity in the target volume and intensity-modulated radiotherapy to escalate the dose in the treatment of non-small-cell lung cancer
    Schwarz, M
    Alber, M
    Lebesque, JV
    Mijnheer, BJ
    Damen, EMF
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02): : 561 - 570
  • [8] INTENSITY-MODULATED RADIOTHERAPY FOR LOCALLY ADVANCED NON-SMALL-CELL LUNG CANCER: A DOSE-ESCALATION PLANNING STUDY
    Lievens, Yolande
    Nulens, An
    Gaber, Mousa Amr
    Defraene, Gilles
    De Wever, Walter
    Stroobants, Sigrid
    Van den Heuvel, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 306 - 313
  • [9] Evaluation of tumor motion effects on dose distribution for hypofractionated intensity-modulated radiotherapy of non-small-cell lung cancer
    Kang, Hyejoo
    Yorke, Ellen D.
    Yang, Jie
    Chui, Chen-Shou
    Rosenzweig, Kenneth E.
    Amols, Howard I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03): : 78 - 89
  • [10] Comparison of inverse-planned three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for non-small-cell lung cancer
    Christian, Judith A.
    Bedford, James L.
    Webb, Steve
    Brada, Michael