Quartz Crystal Microbalance with Dissipation (QCM-D) studies of the viscoelastic response from a continuously growing grafted polyelectrolyte layer

被引:55
|
作者
Duner, Gunnar [1 ]
Thormann, Esben [1 ]
Dedinaite, Andra [1 ,2 ]
机构
[1] KTH Royal Inst Technol, Sch Chem Sci & Engn, Dept Chem Surface & Corros Sci, SE-10044 Stockholm, Sweden
[2] SP Tech Res Inst Sweden, SE-11486 Stockholm, Sweden
关键词
Quartz Crystal Microbalance; QCM-D; Viscoelastic model; Voigt model; Grafting from; Iniferter; Poly(acrylic acid); LIVING RADICAL POLYMERIZATION; ESCHERICHIA-COLI O157-H7; PIEZOELECTRIC IMMUNOSENSOR; SUBSEQUENT HYBRIDIZATION; BIOSENSOR LITERATURE; DNA IMMOBILIZATION; THIN-FILMS; SALMONELLA; FREQUENCY; SURFACE;
D O I
10.1016/j.jcis.2013.07.008
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Poly(acrylic acid) was grown from substrates by photopolymerization, and the grafting process was monitored in situ by Quartz Crystal Microbalance with Dissipation (QCM-D) measurements in a 1:1 v/v mixture of water/ethanol. The polymerization process was monitored into the thick film region, where the change in frequency and dissipation with increasing film mass changes sign as predicted by the Voigt viscoelastic model. Our experimental data are compared with predictions of this model, and satisfactory agreement is found for low overtone numbers. The Voigt model was applied to analyze the measured changes in frequency, Delta f, and dissipation, Delta D, in order to extract information on layer thickness, shear elasticity, mu, and shear viscosity, eta, of the growing film. The increasing rate of changes in Delta f and Delta D observed after about 150 s of polymerization was found to correlate with an increasing growth rate of the film thickness. For longer polymerization times a close to linear increase in thickness with time was observed. The sensitivity, defined as the derivatives of Delta f and Delta D with respect to thickness, depends on overtone number and is different for the frequency and dissipation signals - facts that should be considered when investigating small changes in thick films used in e.g. sensor applications. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:229 / 234
页数:6
相关论文
共 50 条
  • [1] Viscoelastic Properties of Electrospray-Deposited Polymer Shells via Quartz Crystal Microbalance With Dissipation (QCM-D)
    Green-Warren, Robert A.
    McAllister, Noah M.
    Pasupathy, Parameshwaran
    Pelegri, Assimina A.
    Singer, Jonathan P.
    Murthy, N. Sanjeeva
    MACROMOLECULAR MATERIALS AND ENGINEERING, 2024, 309 (12)
  • [2] Challenges associated with Quartz Crystal Microbalance with Dissipation (QCM-D) as a wettability screening tool
    Erzuah, Samuel
    Fjelde, Ingebret
    Omekeh, Aruoture Voke
    OIL & GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES, 2018, 73
  • [3] Investigating calcite growth rates using a quartz crystal microbalance with dissipation (QCM-D)
    Cao, Bo
    Stack, Andrew G.
    Steefel, Carl I.
    DePaolo, Donald J.
    Lammers, Laura N.
    Hu, Yandi
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2018, 222 : 269 - 283
  • [4] Investigation of fibrinogen adsorption on solid surface by quartz crystal microbalance with dissipation(QCM-D) and ELISA
    Li Guicai
    Shi Xiaoli
    Yang Ping
    Zhao Ansha
    Huang Nan
    SOLID STATE IONICS, 2008, 179 (21-26) : 932 - 935
  • [5] Adsorption of pectins and their enzymatic degradation probed by a quartz crystal microbalance with dissipation monitoring (QCM-D)
    Zhang, Xiao
    Roman, Maren
    Esker, Alan R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [6] In situ adsorption study of carboxymethylcellulose and sodium oleate on quartz using a quartz crystal microbalance with dissipation (QCM-D)
    Yin, Manyi
    Hao, Hongying
    Wei, Hong
    Li, Mengyao
    Shao, Ziqiang
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2024, 685
  • [7] Protein Adsorption Behaviors on PLLA Surface Studied by Quartz Crystal Microbalance with Dissipation Monitoring (QCM-D)
    Zeng, Rong
    Zhang, Yi
    Tu, Mei
    Zhou, Changren
    MATERIALS RESEARCH, PTS 1 AND 2, 2009, 610-613 : 1219 - 1223
  • [8] Rapid Assessment of Glass Etching/Corrosion using the Quartz Crystal Microbalance with Dissipation Monitoring, QCM-D
    Macakova, Lubica
    Kjellin, Mikael
    Andersson, Martin
    Lof, Leif
    Wnukowska, Halina
    TENSIDE SURFACTANTS DETERGENTS, 2014, 51 (06) : 484 - 490
  • [9] Applications of the QCM-D method (quartz crystal microbalance with dissipation monitoring) to solid-liquid interface
    Kasemo, Bengt H.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [10] In situ kinetic study of zinc sulfide activation using a quartz crystal microbalance with dissipation (QCM-D)
    Teng, Fucheng
    Liu, Qingxia
    Zeng, Hongbo
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2012, 368 : 512 - 520