Magnetic Induction Measurements with a Six Channel Coil Array for Vital Parameter Monitoring

被引:0
|
作者
Cordes, Axel [1 ]
Heimann, Konrad [2 ]
Leonhardt, Steffen [1 ]
机构
[1] Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Aachen, Germany
[2] Univ Aachen, RWTH, Dept Neonatol, Univ Childrens Hosp, Aachen, Germany
关键词
SYSTEM;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vital parameter monitoring on neonatal intensive care units is essential but very stressful for patients during daily routine care. For contact-less monitoring of breathing and heart activity, magnetic induction measurements are applicable in research scenarios. For monitoring both vital parameters in newborn intensive care wards, we developed a Multi Channel Simultaneous Magnetic Induction Measurement System (MUSIMITOS2+). In this article we now evaluate the technical requirements of a coil array for vital parameter monitoring and finally present a multichannel coil array with 6 excitation and measurement channels combined as axial gradiometers for the specific measurement scenario. This array will be stored underneath the child. As a test case we will present data of a animal trial with the described coil array and the measurement device MUSIMITOS2+.
引用
收藏
页码:602 / 604
页数:3
相关论文
共 37 条
  • [1] A Full Digital Magnetic Induction Measurement Device for Non-Contact Vital Parameter Monitoring (MONTOS)
    Cordes, Axel
    Arts, Martijn
    Leonhardt, Steffen
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 582 - 585
  • [2] Respiration Monitoring Based on Magnetic Induction Using a Single Coil
    Teichmann, Daniel
    Foussier, Jerome
    Leonhardt, Steffen
    2010 BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2010, : 37 - 40
  • [3] Increasing the Capacity of Magnetic Induction Communication Using MIMO Coil-Array
    Guo, Hongzhi
    Sun, Zhi
    2016 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM), 2016,
  • [4] Parameter estimation of induction motor at standstill with magnetic flux monitoring
    Castaldi, P
    Tilli, A
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2005, 13 (03) : 386 - 400
  • [5] Development of a Device for Measuring the Sensitivity Area of coil Arrays for Magnetic Induction Measurements
    Cordes, Axel
    Santos, Susana Aguiar
    Leonhardt, Steffen
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4959 - 4962
  • [6] A Six-Channel Pediatric Coil Array for Detection of Children Spinal Pathologies by MRI at 1.5 Tesla
    Lopez Terrones, Marcos Alonso
    Solis-Najera, Sergio Enrique
    XIII MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2014, 1626 : 82 - 85
  • [7] 64-channel array coil for single echo acquisition magnetic resonance imaging
    McDougall, MP
    Wright, SM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 386 - 392
  • [8] Eight-channel decoupled array for cervical spinal cord imaging at 3T: six-channel posterior and two-channel anterior array coil
    Sapkota, Nabraj
    Thapa, Bijaya
    Lee, YouJung
    Kim, Taeho
    Bisson, Erica F.
    Shah, Lubdha M.
    Rose, John W.
    Jeong, Eun-Kee
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2016, 46 (02) : 90 - 99
  • [9] Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers
    Iivanainen, Joonas A.
    Read, Timothy S.
    Yang, Xianjin
    Junor, William
    Thrasher, Daniel A.
    IEEE SENSORS LETTERS, 2025, 9 (02)
  • [10] A magnetic induction measurement system for adult vital sign monitoring: evaluation of capacitive and inductive effects
    Mahdavi, H.
    Rosell-Ferrer, J.
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434