Synchrotron measurements of the energy response functions of CdTe Medipix2 MXR detectors with pixel pitches of 110 and 165 μm

被引:0
|
作者
Zuber, M. [1 ]
Koenig, T. [1 ,2 ]
Hamann, E. [2 ,3 ]
Butzer, J. [2 ]
Cecilia, A. [2 ,3 ]
Fiederle, M. [3 ]
Oelfke, U. [1 ]
机构
[1] German Canc Res Ctr, D-69120 Heidelberg, Germany
[2] Karlsruhe Inst Technol, Inst Photon Sci & Synchrotron Radiat IPS ANKA, D-76344 Eggenstein Leopoldshafen, Germany
[3] Univ Freiburg, Freiburg Mat Res Ctr FMF, D-79104 Freiburg, Germany
来源
关键词
Solid state detectors; Pixelated detectors and associated VLSI electronics; Detector alignment and calibration methods (lasers sources particle-beams); X-ray radiography and digital radiography (DR);
D O I
10.1088/1748-0221/7/12/C12018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The energy resolution of photon counting pixel detectors depends strongly on the pixel pitch. Small pixels increase the effects of characteristic X-rays and the sharing of charges between adjacent pixels. To investigate the effects of different pixel pitches, measurements with Medipix2 MXR detectors attached to CdTe sensors with pixel pitches of 110 and 165 m m were carried out at the Topo-Tomo beamline of the ANKA synchrotron at the Karlsruhe Institute of Technology (KIT). Photo peaks are measured at a number of energies and are used to calculate the fraction of events in the photo peak compared to the total. Finally, we investigate the linearity of the energy calibration curves as a function of the pixel pitch.
引用
收藏
页数:6
相关论文
共 6 条
  • [1] Synchrotron measurements of the energy response functions of CdTe Medipix2 MXR detectors with pixel pitches of 110 and 165 μm
    German Cancer Research Center , Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
    不详
    不详
    J. Instrum., 12
  • [2] Medipix2: Processing and measurements of GaAs pixel detectors
    Zwerger, Andreas
    Fauler, Alex
    Fiederle, Michael
    Jakobs, Karl
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 23 - 26
  • [3] On the energy response function of a CdTe Medipix2 Hexa detector
    Koenig, Thomas
    Zwerger, Andreas
    Zuber, Marcus
    Schuenke, Patrick
    Nil, Simeon
    Guni, Ewald
    Fauler, Alex
    Fiederle, Michael
    Oelfke, Uwe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S265 - S268
  • [4] Spectral response of a silicon detector with 220 μm pixel size bonded to MEDIPIX2
    Frojdh, Erik
    Frojdh, Anna
    Norlin, Borje
    Frojdh, Christer
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S125 - S127
  • [5] Comparison of Simulated and Measured Energy Response Spectra for a Medipix2 Detector using CdTe as Sensor Material
    Durst, Juergen
    Guni, Ewald
    Michel, Thilo
    Anton, Gisela
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1749 - 1752
  • [6] Measurements of Ultra-Fast single photon counting chip with energy window and 75 μm pixel pitch with Si and CdTe detectors
    Maj, P.
    Grybos, P.
    Kasinski, K.
    Koziol, A.
    Krzyzanowska, A.
    Kmon, P.
    Szczygiel, R.
    Zoladz, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12