Application of the evaporative light scattering detector to analytical problems in polymer science

被引:51
|
作者
Arndt, J. H. [1 ]
Macko, T. [1 ]
Bruell, R. [1 ]
机构
[1] Fraunhofer Inst Struct Durabil & Syst Reliabil, Div Plast, Grp Mat Analyt, D-64289 Darmstadt, Germany
关键词
Evaporative light scattering detector; Synthetic polymers; PERFORMANCE LIQUID-CHROMATOGRAPHY; SIZE-EXCLUSION CHROMATOGRAPHY; CHEMICAL-COMPOSITION DISTRIBUTION; THERMODYNAMICALLY GOOD SOLVENTS; ETHYLENE-PROPYLENE COPOLYMERS; FULL ADSORPTION MECHANISMS; TEMPERATURE GRADIENT HPLC; FATTY ALCOHOL ETHOXYLATES; CHARGED AEROSOL DETECTOR; FIELD-FLOW FRACTIONATION;
D O I
10.1016/j.chroma.2013.08.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last two decades the evaporative light scattering detector (ELSD) has found more and more use in liquid chromatography (LC) of synthetic polymers. The reason behind this is that it can be used for a significantly wider variety of analyte/solvent combinations. Although in many of the applications the ELSD has been used in a qualitative manner, it can also be used quantitatively. For quantitative interpretation of analyses it is, in the case of synthetic polymers, essential to know how parameters, which characterize a polymer sample (i.e., molar mass and chemical composition), as well as parameters, which are a consequence of the LC separation (i.e., composition and flow rate of the mobile phase, its composition), influence the response of the ELSD. This review gives a tabulated overview over applications of ELS detectors in polymer analysis. The influence of parameters arising from either the polymer side or the chromatographic separation is discussed in detail and, in addition, the influence of the ELS detector's running conditions, i.e. type and flow rate of gas and temperature of nebulizer and evaporator), will be reviewed. This information will prove valuable whenever the calibration of an ELSD for the quantitative analysis of synthetic polymers is attempted. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [1] THE APPLICATION OF AN EVAPORATIVE LIGHT-SCATTERING DETECTOR IN POLYMER ANALYSIS
    SCHULTZ, R
    ENGELHARDT, H
    CHROMATOGRAPHIA, 1990, 29 (11-12) : 517 - 522
  • [2] Evaporative light scattering detector
    不详
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (01) : 209 - 209
  • [3] Polyethylene characterization by analytical temperature rising elution fractionation with evaporative light scattering detector
    Boborodea, Adrian
    Brookes, Alan
    O'Donohue, Stephen
    POLYMER TESTING, 2018, 72 : 172 - 177
  • [4] Optimizing the sensitivity of an evaporative light scattering detector
    Pennanec, R
    Froehlich, P
    AMERICAN LABORATORY, 2005, 37 (16) : 13 - +
  • [5] Linearization of evaporative light scattering detector signal
    Boborodea, Adrian
    O'Donohue, Stephen
    INTERNATIONAL JOURNAL OF POLYMER ANALYSIS AND CHARACTERIZATION, 2017, 22 (08) : 685 - 691
  • [6] On the Issue of Characteristic Evaporative Light Scattering Detector Response
    Mojsiewicz-Pienkowska, Krystyna
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 39 (02) : 89 - 94
  • [7] Improving Quantitative Measurements for the Evaporative Light Scattering Detector
    B. T. Mathews
    P. D. Higginson
    R. Lyons
    J. C. Mitchell
    N. W. Sach
    M. J. Snowden
    M. R. Taylor
    A. G. Wright
    Chromatographia, 2004, 60 : 625 - 633
  • [8] Improving quantitative measurements for the evaporative light scattering detector
    Mathews, BT
    Higginson, PD
    Lyons, R
    Mitchell, JC
    Sach, NW
    Snowden, MJ
    Taylor, MR
    Wright, AG
    CHROMATOGRAPHIA, 2004, 60 (11-12) : 625 - 633
  • [10] Development and Evaluation of Micro Evaporative Light Scattering Detector
    Wang Yu-Hong
    Liu Fang
    Zhao Hui
    Wang Jian-Min
    Wang Yan
    Yan Chao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (10) : 1622 - 1626