Enhanced Chlorine Dioxide Decay in the Presence of Metal Oxides: Relevance to Drinking Water Distribution Systems

被引:28
|
作者
Liu, Chao [1 ]
von Gunten, Urs [2 ,3 ]
Croue, Jean-Philippe [1 ]
机构
[1] King Abdullah Univ Sci & Technol, Water Desalinat & Reuse Ctr, Thuwal 239556900, Saudi Arabia
[2] Eawag, Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland
[3] Ecole Polytech Fed Lausanne, Sch Architecture Civil & Environm Engn ENAC, CH-1015 Lausanne, Switzerland
关键词
DISINFECTION BY-PRODUCTS; BROMATE FORMATION; RATE CONSTANTS; CHLORATE ION; KINETICS; ADSORPTION; MECHANISM; GOETHITE; IRON(II); PIPE;
D O I
10.1021/es4015103
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chlorine dioxide (ClO2) decay in the presence of typical metal oxides occurring in distribution systems was investigated. Metal oxides generally enhanced ClO2 decay in a second-order process via three pathways: (1) catalytic disproportionation with equimolar formation of chlorite and chlorate, (2) reaction to chlorite and oxygen, and (3) oxidation of a metal in a reduced form (e.g., cuprous oxide) to a higher oxidation state. Cupric oxide (CuO) and nickel oxide (NiO) showed significantly stronger abilities than goethite (alpha-FeOOH) to catalyze the ClO2 disproportionation (pathway 1), which predominated at higher initial ClO2 concentrations (56-81 mu M). At lower initial ClO2 concentrations (13-31 mu M), pathway 2 also contributed. The CuO-enhanced ClO2 decay is a base-assisted reaction with a third-order rate constant of 1.5 x 10(6) M-2 s(-1) in the presence of 0.1 g L-1 CuO at 21 +/- 1 degrees C, which is 4-5 orders of magnitude higher than in the absence of CuO. The presence of natural organic matter (NOM) significantly enhanced the formation of chlorite and decreased the ClO2 disproportionation in the CuO-ClO2 system, probably because of a higher reactivity of CuO-activated ClO2 with NOM. Furthermore, a kinetic model was developed to simulate CuO-enhanced ClO2 decay at various pH values. Model simulations that agree well with the experimental data include a pre-equilibrium step with the rapid formation of a complex, namely, CuO-activated Cl2O4. The reaction of this complex with OH- is the rate-limiting and pH-dependent step for the overall reaction, producing chlorite and an intermediate that further forms chlorate and oxygen in parallel. These novel findings suggest that the possible ClO2 loss and the formation of chlorite/chlorate should be carefully considered in drinking water distribution systems containing copper pipes.
引用
收藏
页码:8365 / 8372
页数:8
相关论文
共 50 条
  • [1] Kinetic models of chlorine decay in drinking water distribution systems
    Vasconcelos, JJ
    Boulos, PF
    Clark, RM
    COMPUTER METHODS AND WATER RESOURCES III, 1996, : 413 - 421
  • [2] Simulation of chlorine decay in drinking-water distribution systems
    Ozdemir, ON
    Ucak, A
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2002, 128 (01): : 31 - 39
  • [3] The role of metal oxides on oxidant decay and disinfection byproduct formation in drinking waters: Relevance to distribution systems
    Liu, Chao
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2021, 110 : 140 - 149
  • [4] The role of metal oxides on oxidant decay and disinfection byproduct formation in drinking waters: Relevance to distribution systems
    Chao Liu
    Journal of Environmental Sciences, 2021, 110 (12) : 140 - 149
  • [5] Modeling Chlorine decay in drinking water distribution systems using aquasim
    Madzivhandila V.A.
    Chirwa E.M.N.
    Chirwa, Evans M. N. (evans.chirwa@up.ac.za), 1600, Italian Association of Chemical Engineering - AIDIC (57): : 1111 - 1116
  • [6] Lead minerals found in drinking water distribution systems increase chlorine dioxide decay to a single inorganic product
    Reuter, Margaret M.
    Lastoskie, Christian M.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2021, 7 (02) : 417 - 426
  • [7] The Mortality of Nematodes in Drinking Water in the Presence of Ozone, Chlorine Dioxide, and Chlorine
    Kos, Jasna
    Brmez, Mirjana
    Markic, Marinko
    Sipos, Laszlo
    OZONE-SCIENCE & ENGINEERING, 2020, 42 (02) : 120 - 127
  • [8] Evaluation of chlorine decay kinetics expressions for drinking water distribution systems modelling
    Kastl, G.J.
    Fisher, I.H.
    Jegatheesan, V.
    Aqua, 1999, 48 (06): : 219 - 226
  • [9] Relative importance of the phenomena responsible for chlorine decay in drinking water distribution systems
    Kiéné, L
    Lu, W
    Lévi, Y
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (06) : 219 - 227
  • [10] Evaluation of chlorine decay kinetics expressions for drinking water distribution systems modelling
    Kastl, GJ
    Fisher, IH
    Jegatheesan, V
    JOURNAL OF WATER SERVICES RESEARCH AND TECHNOLOGY-AQUA, 1999, 48 (06): : 219 - 226