ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH LARS ARTIFICIAL LIGAMENT: AN 8-15-YEAR FOLLOW-UP

被引:6
|
作者
Wang, Cho-Lin [1 ]
Hsiao, Chih-Kun [2 ]
Ku, Ming-Chou [3 ]
Chang, Chih-Han [1 ]
机构
[1] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 701, Taiwan
[2] E Da Hosp, Dept Med Res, Kaohsiung 824, Taiwan
[3] Show Chwan Mem Hosp, Dept Orthopaed Surg, Changhua, Taiwan
关键词
ACL reconstruction; LARS artificial ligament; Lysholm score; Tegner scale; ACL RECONSTRUCTION; KNEE; BIOCOMPATIBILITY; COMPLICATIONS; REPLACEMENT; PROSTHESIS; INGROWTH; MOTION; RANGE;
D O I
10.1142/S0219519413500462
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this study was to evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction with an artificial ligament of the Ligament Augmentation and Reconstruction System (LARS) via an 8-15-year follow-up. Between January 1996 and January 2003, 38 patients received arthroscopic anterior cruciate reconstruction with the LARS artificial ligament at the Show Chwan Memorial Hospital, Changhua, Taiwan. Among them, 28 cases were included in this study. Excluding two failure cases, 26 cases were involved in the statistical analysis of various clinical assessments. The mean follow-up period after reconstruction was 11.4 +/- 1.9 years. Assessment of clinical results included physical examination, magnetic resonance imaging, radiography, KT-1000 arthrometer test for knee stability, range of motion measurement, Lysholm score, and Tegner scale activity evaluations. The outcomes showed that among these 28 follow-up patients, there were two failure cases. The survival rate of LARS ligament reconstruction in this long-term follow-up was 92.9%. Among the 26 clinical assessed cases, the stability of the knee joint was improved as the anterior translation displacement measured by arthrometer reduced from 7.0 +/- 3.1 mm (range: 4-17 mm) pre-operatively to 1.7 +/- 1.7 mm (range: 0-6 mm) post-operatively. The Lysholm score improved from 39.7 +/- 11.5 pre-operatively to 85.9 +/- 19.6 post-operatively. Tegner activity scale improved from 3.2 +/- 1.5 pre-operatively to 5.4 +/- 2.4 post-operatively. All three improvements have statistic significance as the p-values were less than 0.05. In conclusion, ruptured ACL reconstruction with LARS artificial ligament has a survival rate of 92.9% and complication rate of 28.6% in this 8-15-year follow-up.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Anterior cruciate ligament reconstruction with LARS™ artificial ligament results at a mean follow-up of eight years
    Paolo Domenico Parchi
    Ciapini Gianluca
    Lorenzo Dolfi
    Alessandro Baluganti
    Piolanti Nicola
    Fabio Chiellini
    Michele Lisanti
    [J]. International Orthopaedics, 2013, 37 : 1567 - 1574
  • [2] Anterior cruciate ligament reconstruction with LARS™ artificial ligament results at a mean follow-up of eight years
    Parchi, Paolo Domenico
    Gianluca, Ciapini
    Dolfi, Lorenzo
    Baluganti, Alessandro
    Nicola, Piolanti
    Chiellini, Fabio
    Lisanti, Michele
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (08) : 1567 - 1574
  • [3] Anterior Cruciate Ligament Reconstruction With LARS Artificial Ligament: A Multicenter Study With 3-to 5-Year Follow-up
    Gao, Kai
    Chen, Shiyi
    Wang, Lide
    Zhang, Weiguo
    Kang, Yifan
    Dong, Qirong
    Zhou, Haibin
    Li, Linan
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (04): : 515 - 523
  • [4] Arthroscopic reconstruction of the anterior cruciate ligament with the LARS artificial ligament: thirty-six to fifty-two months follow-up study
    Ye, J. X.
    Shen, G. S.
    Zhou, H. B.
    Xu, W.
    Xie, Z. G.
    Dong, Q. R.
    Xu, Y. J.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2013, 17 (11) : 1438 - 1446
  • [5] Hamstring tendon autograft versus LARS artificial ligament for arthroscopic posterior cruciate ligament reconstruction in a long-term follow-up
    Xinxian Xu
    Tingting Huang
    Zhongtang Liu
    Hong Wen
    Luyou Ye
    Yuezheng Hu
    Huachen Yu
    Xiaoyun Pan
    [J]. Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1753 - 1759
  • [6] Hamstring tendon autograft versus LARS artificial ligament for arthroscopic posterior cruciate ligament reconstruction in a long-term follow-up
    Xu, Xinxian
    Huang, Tingting
    Liu, Zhongtang
    Wen, Hong
    Ye, Luyou
    Hu, Yuezheng
    Yu, Huachen
    Pan, Xiaoyun
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (12) : 1753 - 1759
  • [7] Clinical outcomes of anterior cruciate ligament reconstruction using LARS artificial graft with an at least 7-year follow-up
    Jia, Zhenyu
    Xue, Chenchen
    Wang, Wei
    Liu, Tianze
    Huang, Xuan
    Xu, Weidong
    [J]. MEDICINE, 2017, 96 (14)
  • [8] Anterior cruciate ligament reconstruction with and without a ligament augmentation device - Results at 8-year follow-up
    Drogset, JO
    Grontvedt, T
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (06): : 851 - 856
  • [9] RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT USING A LIGAMENT PROSTHESIS - A 2-YEAR FOLLOW-UP
    GILLQUIST, J
    ODENSTEN, M
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (01): : 94 - 95
  • [10] Arthroscopic Posterior Cruciate Ligament Reconstruction Using LARS Artificial Ligament: A Retrospective Study
    Shen, Guangsi
    Xu, Youjia
    Dong, Qirong
    Zhou, Haibin
    Yu, Chen
    [J]. JOURNAL OF SURGICAL RESEARCH, 2012, 173 (01) : 75 - 82