Negative-sequence voltage elimination for distributed generators in grid-feeding operation mode

被引:9
|
作者
Rey, Juan M. [1 ]
Castilla, Miguel [2 ]
Miret, Jaume [2 ]
Velasco, Manel [3 ]
Marti, Pau [3 ]
Mojica-Nava, Eduardo [4 ]
机构
[1] Univ Ind Santander UIS, Escuela Ingn Elect Elect & Telecomunicac E3T, Bucaramanga 680002, Colombia
[2] Tech Univ Catalonia UPC, Dept Elect Engn, Vilanova I La Geltru 08800, Spain
[3] Tech Univ Catalonia UPC, Dept Automat Control, Barcelona 08028, Spain
[4] Univ Nacl Colombia, Dept Elect & Elect Engn, Bogota 111321, Colombia
关键词
power grids; power supply quality; closed loop systems; power convertors; transfer functions; power generation control; distributed power generation; switching convertors; control system synthesis; electric current control; power system stability; flowcharting; distributed generators; grid-feeding operation mode; power quality; distributed systems; voltage imbalances; control system; distributed generation power converters; standard operation modes; negative-sequence voltage elimination technique; grid configuration; control architecture; controller flowchart; control design guidelines; complex transfer function approach; REACTIVE POWER-CONTROL; CONTROL SCHEME; CONNECTED CONVERTERS; IMPEDANCE ESTIMATION; CONTROL STRATEGIES; 3-PHASE INVERTERS; DYNAMIC PHASORS; SUPPORT CONTROL; SYSTEMS; CAPABILITY;
D O I
10.1049/iet-pel.2019.1023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A major concern of the power quality in distributed systems is related to the mitigation of voltage imbalances. This function can be implemented directly in the control system of the distributed generation power converters working simultaneously with the standard operation modes. This study presents a negative-sequence voltage elimination technique for distributed generators in grid-feeding operation mode. The proposal guarantees a complete elimination of the negative-sequence voltage, while operating without a priori in-depth knowledge of the grid configuration and its characteristics. The proposed control architecture is presented together with its pseudocode, a controller flowchart and a discussion of the implementation aspects. A closed-loop modelling is derived based on a complex transfer function approach, which is used to determine stability margins and control design guidelines. A laboratory setup was implemented to verify the performance of the proposed strategy.
引用
收藏
页码:1764 / 1774
页数:11
相关论文
共 50 条
  • [41] Independent positive- and negative-sequence control for MMC-SAPF with unbalanced PCC voltage
    Li, Chengjing
    Dai, Ke
    Lin, Derong
    Xu, Chen
    Chen, Cai
    Dai, Ziwei
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 1823 - 1829
  • [42] Distributed virtual negative-sequence impedance control for accurate imbalance power sharing in islanded microgrids
    Kim, Sunghyok
    Hyon, Songchol
    Kim, Chonung
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2018, 16 : 28 - 36
  • [43] D-STATCOM With Positive-Sequence Admittance and Negative-Sequence Conductance to Mitigate Voltage Fluctuations in High-Level Penetration of Distributed-Generation Systems
    Lee, Tzung-Lin
    Hu, Shang-Hung
    Chan, Yu-Hung
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (04) : 1417 - 1428
  • [44] Perturb and Observe-Based Control of Four-Leg Grid-Feeding Inverters to Mitigate Voltage Imbalances in Low-Voltage Microgrids
    Das G.
    Hazarika D.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (05) : 1707 - 1717
  • [45] Operation of Islanded Microgrid at Constant Frequency with Distributed Grid- supporting Generators
    Zhang, Daming
    2016 IEEE 2ND ANNUAL SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2016,
  • [46] Grid reconnection detection for synchronous distributed generators in stand-alone operation
    Jouybari-Moghaddam, Hessamoddin
    Hosseinian, Seyed Hossein
    Vahidi, Behrooz
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (01): : 138 - 154
  • [47] Control Scheme of Cascaded H-Bridge STATCOM Using Zero-Sequence Voltage and Negative-Sequence Current
    Hatano, Nobuhiko
    Ise, Toshifumi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 543 - 550
  • [48] Fundamental Positive- and Negative-Sequence Estimator for Grid Synchronization Under Highly Disturbed Operating Conditions
    Roncero-Sanchez, Pedro
    del Toro Garcia, Xavier
    Parreno Torres, Alfonso
    Feliu, Vicente
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (08) : 3733 - 3746
  • [49] Enhanced Local Grid Voltage Support Method for High Penetration of Distributed Generators
    Demirok, Erhan
    Sera, Dezso
    Rodriguez, Pedro
    Teodorescu, Remus
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 2481 - 2485
  • [50] Line-Start Permanent Magnet Synchronous Motor Supplied with Voltage Containing Negative-Sequence Subharmonics
    Gnacinski, Piotr
    Peplinski, Marcin
    Muc, Adam
    Hallmann, Damian
    ENERGIES, 2024, 17 (01)