3D ultrasound centerline tracking of abdominal vessels for endovascular navigation

被引:16
|
作者
Zhang, L. [1 ,2 ]
Parrini, S. [1 ]
Freschi, C. [1 ]
Ferrari, V. [1 ]
Condino, S. [1 ]
Ferrari, M. [1 ,3 ]
Caramella, D. [3 ]
机构
[1] Univ Pisa, EndoCAS Ctr, Pisa, Italy
[2] Capital Med Univ, Sch Biomed Engn, Beijing, Peoples R China
[3] Univ Pisa, Dipartimento Integrato Interistituz, Pisa, Italy
关键词
3D ultrasound; Centerline extraction; Centerline tracking; Image guided surgery; Endovascular; SEGMENTATION; SURGERY; SYSTEM; PLATFORM;
D O I
10.1007/s11548-013-0917-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vessel lumen centerline extraction is important for intraoperative tracking of abdominal vessels and guidance of endovascular instruments. Three-dimensional ultrasound has gained increasing acceptance as a safe and convenient surgical image guidance modality. We aimed to optimize vascular centerline detection and tracking in 3D ultrasound. To overcome the intrinsic limitation of low ultrasound image quality, an active contour method (snake) was used to track changes in vessel geometry. We tested two variants of a classic snake using the image gradient and gradient vector field (GVF) as external forces. We validated these methods in liver ultrasound images of 10 healthy volunteers, acquired at three breath-holding instances during the exhalation phase. We calculated the distances between the vessel centerlines as detected by algorithms and a gold standard consisting of manual annotations performed by an expert. Both methods (GVF and image gradient) can accurately estimate the actual centerlines with average Euclidean distances of 0.77 and 1.24 mm for GVF and gradient, respectively. Both methods can automatically follow vessel morphology and position changes. The proposed approach is feasible for liver vessel centerline extraction from 3D ultrasound images. The algorithm can follow the movement of the vessels during respiration; further improvements of hardware components are needed for a real-time implementation.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 50 条
  • [1] 3D ultrasound centerline tracking of abdominal vessels for endovascular navigation
    L. Zhang
    S. Parrini
    C. Freschi
    V. Ferrari
    S. Condino
    M. Ferrari
    D. Caramella
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 127 - 135
  • [2] 3D guide wire tracking for navigation in endovascular interventions
    Baert, SAM
    van Walsum, T
    Niessen, WJ
    MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 : 379 - 387
  • [3] Error Analysis for a navigation system using 3D abdominal ultrasound
    Iommi, David
    Valladares, Alejandra
    Figl, Michael
    Hummel, Johann
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [4] A navigation system for flexible endoscopes using abdominal 3D ultrasound
    Hoffmann, R.
    Kaar, M.
    Bathia, Amon
    Bathia, Amar
    Lampret, A.
    Birkfellner, W.
    Hummel, J.
    Figl, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5545 - 5558
  • [5] 3D multiscale vessel enhancement based centerline extraction of blood vessels
    Kumar, Rahul Prasanna
    Albregtsen, Fritz
    Reimers, Martin
    Lango, Thomas
    Edwin, Bjorn
    Elle, Ole Jakob
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [6] Comparison of two navigation system designs for flexible endoscopes using abdominal 3D Ultrasound
    Kaar, Marcus
    Hoffmann, Rainer
    Bergmann, Helmar
    Figl, Michael
    Bloch, Christoph
    Kratochwil, Alfred
    Birkfellner, Wolfgang
    Hummel, Johann
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [7] Interactive 3D Liver Vessels Centerline Extraction based on Moving Sphere Model
    Huang Zhanpeng
    Jiang Shizhong
    Liu Yaohui
    Bao Susu
    2014 INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE, ELECTRONICS AND ELECTRICAL ENGINEERING (ISEEE), VOLS 1-3, 2014, : 2100 - +
  • [8] Improved 3D Catheter Shape Estimation Using Ultrasound Imaging for Endovascular Navigation: A Further Study
    Chen, Fang
    Liu, Jia
    Zhang, Xinran
    Zhang, Daoqiang
    Liao, Hongen
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (12) : 3616 - 3629
  • [9] Vision-based endoscope tracking for 3D ultrasound image-guided surgical navigation
    Yang, L.
    Wang, J.
    Ando, T.
    Kubota, A.
    Yamashita, H.
    Sakuma, I.
    Chiba, T.
    Kobayashi, E.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 205 - 216
  • [10] 3D Catheter Guidance including Shape Sensing for Endovascular Navigation
    Jaeckle, Sonja
    Garcia-Vazquez, Veronica
    von Haxthausen, Felix
    Eixmann, Tim
    Sieren, Malte Maria
    Schulz-Hildebrandt, Hinnerk
    Huttmann, Gereon
    Ernst, Floris
    Kleemann, Markus
    Paetz, Torben
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315