Comparison of two trocar-guided trans-vaginal mesh systems for repair of pelvic organ prolapse: a retrospective cohort study

被引:8
|
作者
Lensen, E. J. M. [1 ]
Withagen, M. I. J. [1 ]
Kluivers, K. B. [1 ]
Milani, A. L. [2 ]
Vierhout, M. E. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Obstet & Gynaecol, NL-6500 HB Nijmegen, Netherlands
[2] Reinier de Graaf Grp, Dept Obstet & Gynaecol, Delft, Netherlands
关键词
Mesh complications; Pelvic organ prolapse; Prolift; Prolift plus M; Vaginal mesh; RISK-FACTORS; POLYPROPYLENE MESH; GENITAL PROLAPSE; VAGINAL REPAIR; SURGERY; EXPOSURE; INCONTINENCE; LIGHTWEIGHT;
D O I
10.1007/s00192-013-2098-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The aim of this study was to compare failure and complication rates in patients who underwent a trocar-guided vaginal mesh repair with either a non-absorbable or a partially absorbable mesh. Retrospective analysis of prospectively collected data from consecutive women undergoing either non-absorbable or partially absorbable mesh for symptomatic stage 2 prolapse or higher were evaluated at 12 months. Outcome measures included objective and subjective failure rates, patient's satisfaction, complications and perioperative outcomes. Five hundred and sixty-nine women (347 with non-absorbable mesh, 222 with partially absorbable mesh) were included. Failure rates were similar in the two groups; the re-operation rate in the untreated compartments was higher in the non-absorbable mesh group compared with the partially absorbable mesh group (5 % vs 1 %). Mesh exposure rate in the non-absorbable mesh group was 12 % and in the partially absorbable mesh group it was 5 %. Other complication and patient satisfaction rates were similar. Non-absorbable and partially absorbable mesh demonstrated similar outcome rates at 12 months. The risk of reoperation was lower for partially absorbable mesh. The mesh exposure rate was significantly lower for the partially absorbable mesh group compared with the non-absorbable mesh group.
引用
收藏
页码:1723 / 1731
页数:9
相关论文
共 50 条
  • [1] Comparison of two trocar-guided trans-vaginal mesh systems for repair of pelvic organ prolapse: a retrospective cohort study
    E. J. M. Lensen
    M. I. J. Withagen
    K. B. Kluivers
    A. L. Milani
    M. E. Vierhout
    [J]. International Urogynecology Journal, 2013, 24 : 1723 - 1731
  • [2] Trocar-Guided Transvaginal Mesh Repair of Pelvic Organ Prolapse
    Elmer, Caroline
    Altman, Daniel
    Engh, Marie Ellstroem
    Axelsen, Susanne
    Vaeyrynen, Tapio
    Falconer, Christian
    [J]. OBSTETRICS AND GYNECOLOGY, 2009, 113 (01): : 117 - 126
  • [3] Outcomes and predictors of failure of trocar-guided vaginal mesh surgery for pelvic organ prolapse
    Milani, Alfredo L.
    Withagen, Mariella I. J.
    Vierhout, Mark E.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (05)
  • [4] Trocar-guided trans-vaginal mesh surgery for pelvic organ prolapse: effects on urinary continence and anatomical and functional outcomes. A prospective observational study
    Natale, F.
    Costantini, E.
    La Penna, C.
    Illiano, E.
    Balsamo, R.
    Carbone, A.
    Cervigni, M.
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2017, 210 : 29 - 34
  • [5] Re: Trocar-Guided Mesh Compared With Conventional Vaginal Repair in Recurrent Prolapse
    Raz, Shlomo
    Rogo-Gupta, Lisa
    [J]. EUROPEAN UROLOGY, 2012, 61 (02) : 426 - 426
  • [6] TROCAR-GUIDED TRANS-VAGINAL MESH SURGERY FOR PELVIC ORGAN PROLAPSE: ITS EFFECT ON URINARY INCONTINENCE AND ANATOMICAL AND FUNCTIONAL OUTCOMES. MEDIUM-LONG TERM FOLLOW-UP
    Costantini, Elisabetta
    Cervigni, Mauro
    Vittori, Giorgio
    Natale, Franca
    Salvini, Eleonora
    Manuel, Di Biase
    Sarti, Elena
    Pietropaolo, Amelia
    [J]. NEUROUROLOGY AND URODYNAMICS, 2014, 33 : S22 - S24
  • [7] Trocar-guided mesh repair of vaginal prolapse using partially absorbable mesh: 1 year outcomes
    Milani, Alfredo L.
    Hinoul, Piet
    Gauld, Judi M.
    Sikirica, Vanja
    van Drie, Douglas
    Cosson, Michel
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 (01) : 74.e1 - 74.e8
  • [8] Trocar-Guided Mesh Compared With Conventional Vaginal Repair in Recurrent Prolapse: A Randomized Controlled Trial
    Maher, Christopher
    O'Rourke, Peter
    [J]. OBSTETRICS AND GYNECOLOGY, 2011, 117 (06): : 1435 - 1436
  • [9] Trocar-Guided Mesh Compared With Conventional Vaginal Repair in Recurrent Prolapse A Randomized Controlled Trial
    Withagen, Mariella I.
    Milani, Alfredo L.
    den Boon, Jan
    Vervest, Harry A.
    Vierhout, Mark E.
    [J]. OBSTETRICS AND GYNECOLOGY, 2011, 117 (02): : 242 - 250
  • [10] Trocar-guided total tension-free vaginal mesh repair of post-hysterectomy vaginal vault prolapse
    Milani, Alfredo L.
    Withagen, Mariella I. J.
    Vierhout, Mark E.