Standards and experience in radon measurement and regulation of radon mitigation in Austria

被引:6
|
作者
Maringer, F. J. [1 ,2 ]
Kaineder, H. [3 ]
Nadschlaeger, E. [3 ]
Sperker, S. [3 ]
机构
[1] Fed Off Metrol & Surveying BEV, A-1160 Vienna, Austria
[2] Univ Nat Resources & Appl Live Sci BOKU, Low Level Counting Lab Arsenal, A-1030 Vienna, Austria
[3] Off Upper Austrian Govt, Environm Protect Dept, A-4020 Linz, Austria
关键词
radiation protection; radon measurement; radon mitigation; radon standards;
D O I
10.1016/j.apradiso.2007.12.013
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Over the past 15 years scientific research and application-oriented research were carried out in Austria to resolve the radon problem. In this paper, the strategy and progression of radon research in Austria and experience gained by practical implementation of the main findings are shown and discussed comprehensively. The overview includes the results of the national radon survey, radon mitigation and precaution studies, indoor-air studies at kindergartens and schools, soil-gas radon research, and the establishment of national radon precaution and mitigation standards. (C) 2008 IAEA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1644 / 1649
页数:6
相关论文
共 50 条
  • [1] Radon measurement and mitigation activity in Finland
    Valmari, T.
    Arvela, H.
    Reisbacka, H.
    Holmgren, O.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 160 (1-3) : 18 - 21
  • [2] RADON MEASUREMENT STANDARDS AND CALIBRATION - PREFACE
    HUTCHINSON, JMR
    COLLE, R
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (02) : U115 - U115
  • [3] RADON MITIGATION
    ROSE, SL
    NERO, AV
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1990, 32 (06): : 15 - 15
  • [4] Radon Mitigation Approach in a Laboratory Measurement Room
    Blanco-Rodriguez, Patricia
    Alfonso Fernandez-Serantes, Luis
    Otero-Pazos, Alberto
    Luis Calvo-Rolle, Jose
    de Cos Juez, Francisco Javier
    [J]. SENSORS, 2017, 17 (05):
  • [5] MEASUREMENT OF RADON AND RADON PROGENY
    BERNHARDT, DE
    [J]. HEALTH PHYSICS, 1983, 45 (01): : 246 - 246
  • [6] RADON MITIGATION IN SCHOOLS
    LEOVIC, KW
    CRAIG, AB
    SAUM, DW
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1990, 32 (01): : 40 - &
  • [7] Measurement of radon and radon progenies at the German radon reference chamber
    Paul, A
    Honig, A
    Röttger, S
    Keyser, U
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 369 - 375
  • [8] Primary standards of radon
    De Felice, P.
    [J]. METROLOGIA, 2007, 44 (04) : S82 - S86
  • [9] Radon in Austria: metrology and practice
    Maringer, F. J.
    [J]. KERNTECHNIK, 2008, 73 (03) : 127 - 130
  • [10] RADON MAPPING STRATEGIES IN AUSTRIA
    Gruber, V.
    Ringer, W.
    Wurm, G.
    Friedmann, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 65 - 69