Ultrasound cyclo plasty for the management of refractory glaucoma in chinese patients: a before-after study

被引:4
|
作者
Wang, Tao [1 ]
Wang, Ruixue [1 ]
Su, Yu [2 ]
Li, Ning [1 ]
机构
[1] Anhui Med Univ, Dept Ophthalmol, Affiliated Hosp 1, Meishan Rd, Hefei 230022, Anhui, Peoples R China
[2] Anhui Prov Childrens Hosp, Dept Ophthalmol, Hefei 230022, Anhui, Peoples R China
基金
美国国家科学基金会;
关键词
Refractory glaucoma; Ultrasonic cyclo plasty; Hypotony; INTENSITY FOCUSED ULTRASOUND; OPEN-ANGLE GLAUCOMA; THERAPEUTIC ULTRASOUND; INTRAOCULAR-PRESSURE; CILIARY BODY; CYCLOCOAGULATION; DEVICE;
D O I
10.1007/s10792-020-01606-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Cyclocryotherapy and transscleral cyclophotocoagulation are commonly used procedures for the treatment of refractory glaucoma, but still with many complications. Ultrasound cyclo plasty (UCP) is a novel technique that determines a selective and more precise coagulation necrosis of the ciliary body to reduce intraocular pressure (IOP), but its efficacy and safety have been less investigated in Chinese population. This study aimed to evaluate the clinical efficacy and safety of UCP in Chinese patients with refractory glaucoma. Methods We designed a prospective, before-after study involving 36 eyes of 36 patients with refractory glaucoma that underwent uneventful UCP. Mean IOP, mean IOP reduction and subjective pain scale scores before and after UCP were compared to evaluate the efficacy of UCP in these patients. Procedural success defined as no abnormality of the treatment sites, and complications were recorded, along with confirmation of the safety of UCP. Results The 36 UCP patients had a mean IOP of 53.61 +/- 12.4 mmHg and a mean VAS score of 5.69 +/- 3.02 preoperatively. Successful operation was achieved in 28 patients, with a success rate of 77.8%. In the follow-up observation at day 1, day 7, and month 1, 2, 3 and 6 postoperatively, both mean IOP and mean VAS score were significantly lower than those before operation (bothP < 0.0001). The median baseline IOP reduction ranged from 22 to 36%. The mean reduction was 42.5% in 36 patients when taking IOP at the last follow-up visit as the last. No significant changes in visual acuity were achieved in 4 patients after UCP, and no adverse outcomes were present in other patients after timely treatment of complications such as conjunctival hyperemia, subconjunctival hemorrhage, or hyphema. Conclusions UCP is a novel yet reliable option for Chinese patients with refractory glaucoma since its high efficacy and safety.
引用
收藏
页码:549 / 558
页数:10
相关论文
共 50 条
  • [1] Ultrasound cyclo plasty for the management of refractory glaucoma in chinese patients: a before–after study
    Tao Wang
    Ruixue Wang
    Yu Su
    Ning Li
    International Ophthalmology, 2021, 41 : 549 - 558
  • [2] Distribution of ultrasound cyclo plasty probe models in Chinese patients with glaucoma
    Shaoyang Zheng
    DingQiao Wang
    Zhihong Huang
    Liming Chen
    Huanling Hu
    Meng Hu
    Zhixin Tang
    Chengguo Zuo
    Mingkai Lin
    International Ophthalmology, 2023, 43 : 4435 - 4441
  • [3] Distribution of ultrasound cyclo plasty probe models in Chinese patients with glaucoma
    Zheng, Shaoyang
    Wang, Dingqiao
    Huang, Zhihong
    Chen, Liming
    Hu, Huanling
    Hu, Meng
    Tang, Zhixin
    Zuo, Chengguo
    Lin, Mingkai
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4435 - 4441
  • [4] Ultrasound Cyclo Plasty in Eyes with Glaucoma
    Giannaccare, Giuseppe
    Sebastiani, Stefano
    Campos, Emilio C.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (131):
  • [5] Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma
    Pellegrini, Marco
    Sebastiani, Stefano
    Giannaccare, Giuseppe
    Campos, Emilio C.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (02) : 338 - 341
  • [6] Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma
    Marco Pellegrini
    Stefano Sebastiani
    Giuseppe Giannaccare
    Emilio C.Campos
    International Journal of Ophthalmology, 2019, (02) : 338 - 341
  • [7] Ultrasound Cyclo Plasty After Failed Glaucoma Surgery: Outcomes and Complications
    Almobarak, Faisal A.
    Alrubean, Ahmed
    Alsarhani, Waleed K.
    Aljenaidel, Abdullah
    Osman, Essam
    OPHTHALMOLOGY AND THERAPY, 2022, 11 (04) : 1601 - 1610
  • [8] Ultrasound Cyclo Plasty After Failed Glaucoma Surgery: Outcomes and Complications
    Faisal A. Almobarak
    Ahmed Alrubean
    Waleed K. Alsarhani
    Abdullah Aljenaidel
    Essam Osman
    Ophthalmology and Therapy, 2022, 11 : 1601 - 1610
  • [9] Ultrasound Cyclo Plasty in Patients with Open Angle Glaucoma and High Myopia
    Figus, Michele
    Palma, Alessandro
    Covello, Giuseppe
    Agnifili, Luca
    Posarelli, Chiara
    JOURNAL OF GLAUCOMA, 2023, 32 (05) : 420 - 425
  • [10] Ultrasound cyclo plasty for the management of glaucoma secondary to ocular irradiation for choroidal melanoma
    Sebastiani, Stefano
    Asencio-Duran, Monica
    Lavin-Dapena, Cosme
    Manzano-Munoz, Beatriz
    D'Anna-Mardero, Oriana
    Cordero-Ros, Rosa
    Pellegrini, Marco
    Bernabei, Federico
    Mercanti, Andrea
    Scorcia, Vincenzo
    Giannaccare, Giuseppe
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (01) : 184 - 188