A Measurement System to Realize 3-D Carotid Occlusion Measurement From 2-D Conventional Ultrasonography

被引:1
|
作者
Capriglione, Domenico [1 ]
Ferrigno, Luigi [1 ]
Miele, Gianfranco [1 ]
Paciello, Vincenzo [2 ]
Paolillo, Alfredo [2 ]
Sommella, Paolo [2 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Elect & Informat Engn, I-03043 Cassino, Italy
[2] Univ Salerno, Dept Ind Engn, I-84084 Fisciano, Italy
关键词
Biomedical measurements; measurement uncertainty; thickness measurement; volume measurement; biomedical image processing; ultrasonic imaging; PLAQUE VOLUME; VESSEL WALL; QUANTIFICATION;
D O I
10.1109/JSEN.2013.2287298
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel measurement system for the 3-D reconstruction of occlusions of the carotid artery is presented. The proposed system can be added onto a conventional diagnostic ultrasonographic system, so that it can be considered as an upgrade for preexisting equipments. It retrieves information from a set of ordinary 2-D ultrasound images and spatial sensors in order to build a 3-D representation of the vessel and of a possible occlusion and to extract measurements of important medical parameters from them. The geometrical modeling of carotid is dealt with. This paper is also concerned with a metrological characterization of the measurement procedure, including the development of a model for the estimation of the uncertainty according to international standards. Experimental results are also reported and discussed.
引用
收藏
页码:747 / 757
页数:11
相关论文
共 50 条
  • [1] 3-D measurement of 2-D jet by 3-D 3-C SPIV
    Ninomiya, Nao
    Tanaka, Yukihisa
    Sotome, Satoshi
    Eda, Masahide
    Watanabe, Atsushi
    JOURNAL OF VISUALIZATION, 2019, 22 (02) : 305 - 312
  • [2] 3-D measurement of 2-D jet by 3-D 3-C SPIV
    Nao Ninomiya
    Yukihisa Tanaka
    Satoshi Sotome
    Masahide Eda
    Atsushi Watanabe
    Journal of Visualization, 2019, 22 : 305 - 312
  • [3] 2-D vision directing laser device for 3-D measurement and modeling
    Wong, AKC
    Xu, T
    Fayek, RE
    2000 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2000), VOLS 1-3, PROCEEDINGS, 2000, : 96 - 102
  • [4] MEASUREMENT OF THE LATERAL VENTRICLES IN THE NEONATAL HEAD: COMPARISON OF 2-D AND 3-D TECHNIQUES
    McLean, Glenda
    Coombs, Peter
    Sehgal, Arvind
    Paul, Eldho
    Zamani, Lily
    Gilbertson, Taryn
    Ptasznik, Ronnie
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (12): : 2051 - 2057
  • [5] Coordinate measurement in 2-D and 3-D geometries using frequency scanning interferometry
    Gibson, SM
    Coe, PA
    Mitra, A
    Howell, DF
    Nickerson, RB
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (07) : 815 - 831
  • [6] 3-D/2-D registration by integrating 2-D information in 3-D
    Tomazevic, D
    Likar, B
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) : 17 - 27
  • [7] 3-D surface profile measurement by 2-D heterodyne low-coherence interferometer
    Matsumoto, H
    Hirai, A
    OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 851 - 852
  • [8] Development of 3-D Electromagnetic Field Intensity Measurement System using Infrared 2-D Lock-in Amplifier
    Chiyo, Noritaka
    Tanaka, Yasuhiro
    Maeno, Takashi
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 37 - 37
  • [9] 3-D measurement system for use in microelectronics
    Lee, Mikyoung
    Pecht, Michael
    Tyson, John
    Schmidt, Timothy
    Advanced Packaging, 2003, 12 (11): : 33 - 34
  • [10] Moving from 2-D design to 3-D
    不详
    MECHANICAL ENGINEERING, 2001, 123 (06) : 18 - 18