Analysis of Current Transfer Process during the Open Operating in Large Current Vacuum Interrupters with Dual-Contact

被引:0
|
作者
Yu, Li [1 ]
Yuan, Shun [2 ]
Li, Feng [3 ]
机构
[1] Shenyang Inst Engn, Dept Elect Engn, Shenyang, Peoples R China
[2] NorthEast China Bur State Elect Regulatory Commis, Shenyang, Peoples R China
[3] NorthEast Elect Power Res Inst Co LTD, Shenyang, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of "dual-contact" structure of vacuum interrupter is proposed in the paper. It consists of main contact and arc contact, which are used to carry rated current and break short circuit current, respectively. During the closing/opening of vacuum circuit breaker, arc contact is first closed and post breaking, however, main contact is post closed and first breaking. So there must be the current transfer process. In this paper, during the breaking process of vacuum circuit breaker, a model of current transfer is used in the investigation of current transfer, and the maximum possible current transfer time is obtained. This analysis is helpful to the research of large current vacuum interrupters with dual-contact.
引用
收藏
页码:197 / 200
页数:4
相关论文
共 50 条
  • [1] Investigation of Current Conditioning Process for Vacuum Interrupters
    Godechot, X.
    Chakraborty, S.
    Papillon, A.
    Berthon, B.
    Triaire, C.
    2016 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 2, 2016,
  • [2] Field Electron Emission Current in Vacuum Interrupters after Large Inrush Current
    Smeets, R. P. P.
    Kuivenhoven, S.
    Chakraborty, S.
    Sandolache, G.
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 157 - 160
  • [3] Analysis on dynamic vacuum pressure in high current vacuum interrupters
    Zou, Jiyan
    Chen, Xuanshu
    Zhang, Hanmin
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 1996, 11 (05): : 19 - 22
  • [4] The Impact of Inrush Current on Field Emission Current of Vacuum Interrupters during Capacitive Current Switching
    Yu, Yongxiang
    Wang, Jianhua
    Yang, He
    Geng, Yingsan
    Liu, Zhiyuan
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 145 - 148
  • [5] Vacuum Large Current Parallel Transfer Numerical Analysis
    Dong, Enyuan
    Hou, Shengkai
    Zheng, Xiang
    Qin, Taotao
    Liu, Guixin
    Zhao, Bing
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2014, 2014
  • [6] Influence of Contact Plate Slots on Inrush Current Prestrike Arc Behaviors of Vacuum Interrupters
    Yu, Yongxiang
    Li, Guoqin
    Geng, Yingsan
    Liu, Zhiyuan
    Wang, Jianhua
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 161 - 164
  • [7] Inrush Current Arc Characteristics In Vacuum Interrupters With Axial Magnetic Field Contact And Butt-Type Contact
    Geng, Yun
    Yu, Yongxiang
    Geng, Yingsan
    Wang, Jianhua
    Liu, Zhiyuan
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 512 - 515
  • [8] Prestrike inrush current arc behavior in AMF vacuum interrupters subjected to contact plate slots
    Yu, Yongxiang
    Yao, Daojin
    Shi, Jie
    Zhou, Wei
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 201
  • [9] Fast Wavelength Switching of a Dual-Contact Two-Color Semiconductor Laser With Current Modulation
    Heinricht, Patrycja
    Brandonisio, Nicola
    O'Brien, Stephen
    Osborne, Simon
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2011, 23 (08) : 513 - 515
  • [10] Dielectric Recovery Process in Vacuum Interrupters Regarding to Contact Materials during Post Arc Interval
    Shemshadi, Asaad
    Salavati, Amir
    Akbari, Asghar
    Bathaee, Seyed Mohammad Taghi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 3059 - 3064