Shear resistance of pinned connections of precast members to monotonic and cyclic loading

被引:86
|
作者
Psycharis, Ioannis N. [1 ]
Mouzakis, Harris P.
机构
[1] Natl Tech Univ Athens, Lab Earthquake Engn, Athens 15780, Greece
关键词
Shear design; Shear resistance; Design of dowels; Connections; Pinned connections; Precast; Prefabrication; Cyclic response; Monotonic response; Seismic design;
D O I
10.1016/j.engstruct.2012.03.051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the major issues in the design of precast structures against earthquakes is the proper design of their connections, mainly the beam-to-column joints. Many different types of such connections are used worldwide, as monolithic, emulative and dry pinned ones. The latter case is the most common solution in southern Europe and elsewhere for single-storey or low-rise precast buildings, and is the subject of the experimental research reported in this paper. The experiments were performed at the Laboratory for Earthquake Engineering of the National Technical University of Athens, Greece in the framework of the European FP7 project, SAFECAST. Precast beam and column elements connected with dowels were tested under monotonic and cyclic, pure shear loading and the research was focused on several design aspects, as the shear ductility capacity of the connections and the effect of various parameters on their strength. The parameters examined include the diameter D of the dowels, their number, their distances d and d(n) from the edges in the longitudinal and the transverse direction of the beam respectively, and the strength of the grout of their ducts. Improvements in the design were also proposed and tested experimentally. The results show that, for small values of the ratio d/D, the strength of the connection is lower in the pull direction than that in the push direction for both monotonic and cyclic loading, due to the early spalling of the cover concrete that occurs. Compared to the strength for monotonic loading, the cyclic response shows significantly lower resistance, less than half the monotonic one. The results for cyclic loading also show that significant values of shear ductility can be achieved by dry pinned joints, provided that the concrete cover of the dowels has sufficient thickness. Comparisons between the experimental results obtained for various design parameters show that secondary effects related to the number of the dowels can occur for large forces during monotonic loading, but are less important for cyclic response. A formula is proposed for the calculation of the shear strength of pinned connections, which can be used in seismic design. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:413 / 427
页数:15
相关论文
共 50 条
  • [1] Nonlinear FE analysis of precast RC pinned beam-to-column connections under monotonic and cyclic shear loading
    Kremmyda, Georgia D.
    Fahjan, Yasin M.
    Tsoukantas, Spyros G.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2014, 12 (04) : 1615 - 1638
  • [2] Nonlinear FE analysis of precast RC pinned beam-to-column connections under monotonic and cyclic shear loading
    Georgia D. Kremmyda
    Yasin M. Fahjan
    Spyros G. Tsoukantas
    Bulletin of Earthquake Engineering, 2014, 12 : 1615 - 1638
  • [3] Performance of Precast Shear Wall Connections Under Monotonic and Cyclic Loading: A State-of-the-Art Review
    Hemamalini, S.
    Vidjeapriya, R.
    Jaya, K. P.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2021, 45 (03) : 1307 - 1328
  • [4] Performance of Precast Shear Wall Connections Under Monotonic and Cyclic Loading: A State-of-the-Art Review
    S. Hemamalini
    R. Vidjeapriya
    K. P. Jaya
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2021, 45 : 1307 - 1328
  • [5] Numerical investigation of the resistance of precast RC pinned beam-to-column connections under shear loading
    Kremmyda, Georgia D.
    Fahjan, Yasin M.
    Psycharis, Ioannis N.
    Tsoukantas, Spyros G.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (09): : 1511 - 1529
  • [6] Horizontal connections for precast concrete shear wall panels under cyclic shear loading
    Soudki, KA
    West, JS
    Rizkalla, SH
    Blackett, B
    PCI JOURNAL, 1996, 41 (03): : 64 - 80
  • [7] Experimental investigation of the response of precast concrete cladding panels with integrated connections under monotonic and cyclic loading
    Psycharis, Ioannis N.
    Kalyviotis, Loannis M.
    Mouzakis, Harris P.
    ENGINEERING STRUCTURES, 2018, 159 : 75 - 88
  • [8] Gusset plate connections under monotonic and cyclic loading
    Walbridge, SS
    Grondin, GY
    Cheng, JJR
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2005, 32 (05) : 981 - 995
  • [9] Monotonic and Reverse-Cyclic Loading of Lag Screw Connections for Log Shear Wall Construction
    Graham, Drew A.
    Carradine, David M.
    Bender, Donald A.
    Dolan, J. Daniel
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2010, 22 (01) : 88 - 95
  • [10] Evaluation of the seismic performance of novel bundled connections precast shear walls under cyclic loading
    Feng, Jian
    Yu, Zihao
    Liu, Guang
    Fan, Xiao
    Zhang, Qian
    Cai, Jianguo
    STRUCTURAL CONCRETE, 2024, 25 (03) : 1953 - 1967