The Value of Contrast-Enhanced Ultrasound versus Doppler Ultrasound in Grading Renal Artery Stenosis

被引:13
|
作者
Cui, Yanhua [1 ,2 ]
Zhang, Quanbin [3 ]
Yan, Jiping [2 ]
Wu, Ji [1 ]
机构
[1] Guangxi Med Univ, Dept Ultrason Med, Affiliated Hosp 1, Nanning 530021, Peoples R China
[2] Shanxi Prov Peoples Hosp, Dept Ultrasound, Taiyuan 030012, Peoples R China
[3] Shanxi Med Univ, Dept Ultrasound, Affiliated Hosp 6, Taiyuan 030008, Peoples R China
基金
中国国家自然科学基金;
关键词
HYPERTENSION; ANGIOGRAPHY; CRITERIA; REVASCULARIZE; ANGIOPLASTY; SONOGRAPHY; DIAGNOSIS; MRA;
D O I
10.1155/2020/7145728
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. This study is aimed at exploring the accuracy of contrast-enhanced ultrasound (CEUS) in grading renal artery stenosis.Methods. 122 renal arteries with suspected renal artery stenosis were selected. DSA, DUS, and CEUS were performed for all patients with suspected renal artery stenosis in the research. DSA was selected as the gold standard. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of CEUS or Doppler ultrasound (DUS) in the diagnosis of renal artery stenosis were analyzed. The consistency between CEUS and digital subtraction angiography (DSA) was compared. The accuracy of DUS or CEUS in grading renal artery stenosis was assessed by the area under the receiver operating characteristic (ROC) curves and compared between groups.Results. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CEUS in the diagnosis of renal artery stenosis were 88.9%, 87.8%, 88.5%, 93.5%, and 80.0%, respectively. There was no significant difference in grading renal artery stenosis between CEUS and DSA (X2=0.643,P=0.424). 77 of the 122 renal arteries were diagnosed with the stenosis rate more than 30% by CEUS. Compared with the results of DSA, the kappa value of CEUS was 0.749 (P<0.05).Conclusion. CEUS is accurate in grading renal artery stenosis, and it may represent the method of choice in diagnosing renal artery stenosis.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Contrast-enhanced Doppler ultrasound of renal artery stenosis: Prologue to a promising future
    Lencioni, R
    Pinto, S
    Cioni, D
    Bartolozzi, C
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (07): : 767 - 773
  • [2] Conventional vascular echography versus contrast-enhanced Doppler ultrasound of renal artery stenosis: sensibility, specificity and accuracy
    Liccese, M
    Ciccone, MM
    Caputo, P
    Parenzan, T
    Morisco, F
    Lanzilotti, MC
    De Carli, N
    Rizzon, P
    EUROPEAN HEART JOURNAL, 2002, 23 : 95 - 95
  • [3] The diagnostic value of contrast-enhanced ultrasound for mesenteric artery stenosis
    Bai, Yang
    Zhu, Yingqiao
    Fan, Yanyan
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 : 311 - 311
  • [4] Sensitivity of contrast-enhanced ultrasound in the evaluation of renal artery stenosis
    Ciccone, M. M.
    Fiorella, A.
    Cito, F.
    Quistelli, G.
    Primitivo, S.
    Sassara, M.
    Pertosa, G. B.
    Favale, S.
    EUROPEAN HEART JOURNAL, 2010, 31 : 503 - 503
  • [5] Transplant renal artery stenosis: Evaluation with contrast-enhanced ultrasound
    Pan, Fu-shun
    Liu, Ming
    Luo, Jia
    Tian, Wen-shuo
    Liang, Jin-yu
    Xu, Ming
    Zheng, Yan-ling
    Xie, Xiao-yan
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 90 : 42 - 49
  • [6] Doppler ultrasound and contrast-enhanced magnetic resonance angiography in assessing carotid artery stenosis
    D'Onofrio, M
    Mansueto, G
    Faccioli, N
    Guarise, A
    Tamellini, P
    Bogina, G
    Mucelli, RP
    RADIOLOGIA MEDICA, 2006, 111 (01): : 93 - 103
  • [7] Utility of color doppler ultrasound in the evaluation of renal artery stenosis in comparison with contrast-enhanced magnetic resonance angiography
    Abuagla, Elnasri M.
    Pei, Tan Sook
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2014, 25 (02) : 309 - 315
  • [8] Renal artery stenosis: value of contrast-enhanced ultrasonography
    A. Drelich-Zbroja
    T. Jargiello
    G. Drelich
    H. Lewandowska-Stanek
    M. Szczerbo-Trojanowska
    Abdominal Imaging, 2004, 29 : 518 - 524
  • [9] Renal artery stenosis: value of contrast-enhanced ultrasonography
    Drelich-Zbroja, A
    Jargiello, T
    Drelich, G
    Lewandowska-Stanek, H
    Szczerbo-Trojanowska, M
    ABDOMINAL IMAGING, 2004, 29 (04): : 518 - 524
  • [10] Measurement of renal blood flow using contrast-enhanced ultrasound in patients with renal artery stenosis
    Rim, SJ
    Ahn, JA
    Kim, HJ
    Lee, HC
    Byun, YS
    Hong, GR
    Kang, SM
    Choi, D
    Jang, Y
    Chung, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 414A - 414A