STUDY ON A COMBINED ISOLATION METHOD FOR LARGE LNG STORAGE TANKS IN SOFT SITE

被引:0
|
作者
Weng, Dagen [1 ]
Liu, Shuai [1 ]
机构
[1] Tongji Univ, Res Inst Struct Engn & Disaster Reduct, Shanghai 200092, Peoples R China
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The fundamental natural frequency that can determine the seismic response of large LNG storage tank is usually within 2Hz similar to 10Hz, it is in the range of predominant frequency of strong ground motion. It has been proved that the isolation control technique can be adopted to mitigate the seismic action on the liquid storage tank in the hard site, but in the soft site, if the conventional isolation design methods are still be used for seismic mitigation of the large LNG storage tank, the problems that the isolation period is too long, and the horizontal displacement of the isolation layer is too large under strong earthquake will be produced. For these problems, a combined isolation design method that is suitable for soft site is proposed in this paper.. Based on the Malhotra's simplified elastic-wall model of liquid storage tank, the simplified multi-mass mechanical model of combined isolated large LNG storage tank is established, and the seismic response of the LNG storage tank under the case of SSE (safety shutdown earthquake) is analyzed. The results show that the seismic-reduced effectiveness of the combined isolated LNG storage tank is obvious, and the horizontal displacement of.isolation layer can be controlled in an acceptable range.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Combined sliding seismic isolation of large LNG storage tank in soft site
    Liu S.
    Xia Z.
    Zhang Y.-C.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2022, 52 (04): : 856 - 864
  • [2] Buckling analysis of domed roofs of large LNG storage tanks
    Ohya, Hiroshi
    Yamamoto, Naoki
    Suzuki, Hidenori
    Ishikawajima-Harima Giho/IHI Engineering Review, 2002, 42 (01): : 22 - 27
  • [3] Evaluation on simulation replacement scheme of isolation base of LNG storage tanks
    Xiao L.
    Fan J.
    Yang F.
    Huang H.
    Zhang B.
    Natural Gas Industry, 2023, 43 (06) : 139 - 147
  • [4] Application of ultrasonic TOFD method for welds of LNG storage tanks
    Hatanaka, Hiroaki
    Ido, Nobukazu
    Furikoma, Michitaka
    Arakawa, Takahiro
    Ishikawajima-Harima Giho/IHI Engineering Review, 2002, 42 (03): : 151 - 156
  • [5] Seismic Response Mitigation of Extra-Large LNG Storage Tanks
    Kharde, S. H.
    Soni, D. P.
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2022, 16 (05)
  • [6] Assessment of Rollover Effects at Large LNG Atmospheric and Pressure Storage Tanks
    Chrz, Vaclav
    15TH CRYOGENICS 2019 IIR INTERNATIONAL CONFERENCE, 2019, : 435 - 441
  • [7] A STUDY OF FLUID-STRUCTURE COUPLED ANALYSIS FOR LARGE LNG STORAGE TANKS IN CONSIDERATION OF UPLIFT
    Hayashi, Shoichiro
    Taniguchi, Tomoyo
    Umeda, Akira
    Yamada, Hisayuki
    Kawasaki, Takumi
    Nagahara, Hitoshi
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, PVP 2011, VOL 8, 2012, : 303 - 312
  • [8] A STUDY OF FORMULARIZATION OF UPLIFT BEHAVIOR AT THE BOTTOM PLATE OF LARGE LNG STORAGE TANKS DURING EARTHQUAKE
    Hayashi, Shoichiro
    Taniguchi, Tomoyo
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2012, PVP 2012, VOL 9, 2012, : 139 - 148
  • [9] A STUDY OF DYNAMIC RESPONSE BEHAVIOR DURING EARTHQUAKE FOR LARGE LNG STORAGE TANKS IN CONSIDERATION OF UPLIFT
    Hayashi, Shoichiro
    Taniguchi, Tomoyo
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2013, VOL 8: SEISMIC ENGINEERING, 2014,
  • [10] Method Study for Finite Element Modeling of Large Oil Storage Tanks
    Ge, Qi
    Xiong, Feng
    Peng, Xiaoyang
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 471 - 476