Partial circuit closure of filtrate in an ECF bleaching plant

被引:4
|
作者
Batista, Leonard de Almeida [1 ,3 ]
Silva, Claudio Mudadu [1 ]
Santos, Erika Nascimben [1 ,2 ]
Colodette, Jorge Luiz [1 ]
Passos Rezende, Ana Augusta [4 ]
Zanuncio, Jose Cola [5 ]
机构
[1] Univ Fed Vicosa, Pulp & Paper Lab, Forest Engn Dept, BR-36570900 Vicosa, MG, Brazil
[2] Proc Engn Dept, H-6725 Szeged, Hungary
[3] Suzano, BR-29197900 Aracruz, ES, Brazil
[4] Univ Fed Vicosa, Civil Engn Dept, BR-36570900 Vicosa, MG, Brazil
[5] Univ Fed Vicosa, Entomol Dept, BR-36570900 Vicosa, MG, Brazil
关键词
bleaching filtrates; consistency control; non-process elements accumulation; oxidation stage; water recirculation; PULP; TECHNOLOGIES; REDUCTION; KRAFT;
D O I
10.1515/npprj-2020-0028
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
The bleaching sector of the wood pulp industry is its largest effluent generator. The aim of this study was to reuse the bleaching filtrate in order to reduce water consumption. The experiment was conducted by simulating the D-0(EP)D-1 bleaching sequence and recirculating different amounts of filtrate from the oxidation stage to control the pulp consistency of the delignification stage (pre-O). Physical, mechanical, chemical and optical properties of the pulp were studied. The accumulation of the non-process elements (NPE) and their effects were evaluated with the Aspen-Plus (R) computer simulator. The results of the computational modeling were satisfactory. The recirculation of filtrates increased the saturation index of the system by 19 %, but remained at sub-saturation levels. The pulp viscosity and elongation remained statistically stable. Recirculation of up to 50 % of the filtrate did not produce differences in pulp brightness; however, there were slight losses in the pulp resistances. In order to maintain 84 % ISO brightness, there was a higher consumption of the bleaching reagents. Up to 50 % of recirculation of the filtrates was accomplished without jeopardizing the system and the pulp quality and resulted in a savings of 55 m(3) h(-1) of water - 7 % of the consumption of the entire mill.
引用
收藏
页码:471 / 478
页数:8
相关论文
共 50 条
  • [1] Increasing the biotreatability of ECF bleaching effluents by ultrafiltration and partial closure of alkaline filtrates
    Svard, SH
    Jour, P
    Bryant, PS
    Basta, J
    Aggarwal, P
    TAPPI INTERNATIONAL ENVIRONMENTAL CONFERENCE, VOLS 1-3, 1999, : 319 - 331
  • [2] Increasing the biotreatability of ECF bleaching effluents by ultrafiltration and partial closure of alkaline filtrates
    Svard, SH
    Jour, P
    Bryant, PS
    Basta, J
    Aggarwal, P
    PULPING CONFERENCE, VOLS 1-3, 1998, : 1165 - 1176
  • [3] A novel bleaching technology adapted to partial bleach plant closure
    Costa, MM
    Landim, A
    Colodette, J
    Silva, CM
    Ventorim, G
    PAPERI JA PUU-PAPER AND TIMBER, 2005, 87 (07): : 442 - 448
  • [4] Significant improvements in ECF bleaching using a minimal capital approach to better filtrate management - Lowering bleaching costs through modified filtrate recycling
    Thakore, A
    Oei, J
    Heimburger, S
    PULP & PAPER-CANADA, 2001, 102 (09) : 40 - 43
  • [5] Scale formation and inhibition in ECF bleaching plant
    Kowata, Kenji
    Kami Pa Gikyoshi/Japan Tappi Journal, 2003, 57 (07): : 70 - 80
  • [6] Significant improvements in ECF bleaching using a minimal capital approach to better filtrate mgmt.
    Thakore, A
    Oei, J
    Heimburger, S
    2000 INTERNATIONAL PULP BLEACHING CONFERENCE, ORAL PRESENTATIONS, 2000, : 249 - 252
  • [7] Closure of the EO stage in the ECF bleach plant
    Savelin, P
    Bergkvist, L
    I997 TAPPI MINIMUM EFFLUENT MILLS SYMPOSIUM, PROCEEDINGS, 1997, : 67 - 71
  • [8] Partial closure in modern bleaching sequences
    Basta, J
    Wane, G
    HerstadSvard, S
    Lundgren, P
    Johansson, N
    Edwards, L
    Gu, YX
    1996 INTERNATIONAL PULP BLEACHING CONFERENCE, BOOKS 1 AND 2, 1996, : 341 - 346
  • [9] Partial closure in modern bleaching sequences
    Basta, J
    Wane, G
    Herstad-Svard, S
    Lundgren, P
    Johansson, N
    Edwards, L
    Gu, YX
    TAPPI JOURNAL, 1998, 81 (04): : 136 - 140
  • [10] Recycling of ECF bleaching plant effluents cleaned by coagulation/flocculation
    Lombardo, G
    Nivelon, S
    Pisicchio, JL
    Suty, H
    INTERNATIONAL ENVIRONMENTAL CONFERENCE & EXHIBIT, BOOKS 1-3, 1998, : 925 - 935