Calibration and validation of a general infiltration model

被引:4
|
作者
Mishra, SK [1 ]
Kumar, SR [1 ]
Singh, VP [1 ]
机构
[1] Natl Inst Hydrol, Roorkee 247667, Uttar Pradesh, India
关键词
infiltration model; calibration; validation; split sampling; curve number; SCS-CN method; sorptivity; hydraulic conductivity;
D O I
10.1002/(SICI)1099-1085(19990815)13:11<1691::AID-HYP818>3.0.CO;2-W
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
A general infiltration model proposed by Singh and Yu(1990) was calibrated and validated using a split sampling approach for 191 sets of infiltration data observed in the states of Minnesota and Georgia in the USA. Of the five model parameters, f(c)(the final infiltration rate), S-o(the available storage space) and exponent 'n' were found to be more predictable than the other two parameters: m (exponent) and a (proportionality factor). A critical examination of the general model revealed that it is related to the Soil Conservation Service (1956) curve number (SCS-CN) method and its parameter S-o is equivalent to the potential maximum retention of the SCS-CN method and is, in turn, found to be a function of soil sorptivity and hydraulic conductivity. The general model was found to describe infiltration rate with time varying curve number. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:1691 / 1718
页数:28
相关论文
共 50 条
  • [1] Aircraft Performance Model Calibration and Validation for General Aviation Safety Analysis
    Puranik, Tejas
    Harrison, Evan
    Chakraborty, Imon
    Mavris, Dimitri
    JOURNAL OF AIRCRAFT, 2020, 57 (04): : 678 - 688
  • [2] Statistical downscaling of general circulation model outputs to precipitation - part 1: calibration and validation
    Sachindra, D. A.
    Huang, F.
    Barton, A.
    Perera, B. J. C.
    INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2014, 34 (11) : 3264 - 3281
  • [3] ADAPT: MODEL USE, CALIBRATION, AND VALIDATION
    Gowda, P. H.
    Mulla, D. J.
    Desmond, E. D.
    Ward, A. D.
    Moriasi, D. N.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1345 - 1352
  • [4] WEPP: MODEL USE, CALIBRATION, AND VALIDATION
    Flanagan, D. C.
    Frankenberger, J. R.
    Ascough, J. C., II
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1463 - 1477
  • [5] STANMOD: MODEL USE, CALIBRATION, AND VALIDATION
    van Genuchten, M. Th.
    Simunek, J.
    Leij, F. J.
    Toride, N.
    Sejna, M.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1353 - 1366
  • [6] DRAINMOD: MODEL USE, CALIBRATION, AND VALIDATION
    Skaggs, R. W.
    Youssef, M. A.
    Chescheir, G. M.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1509 - 1522
  • [7] Choosing the calibration model in assay validation
    Nagaraja, NV
    Paliwal, JK
    Gupta, RC
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (03) : 433 - 438
  • [8] HYDRUS: MODEL USE, CALIBRATION, AND VALIDATION
    Simunek, J.
    van Genuchten, M. Th.
    Sejna, M.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1261 - 1274
  • [9] COUPMODEL: MODEL USE, CALIBRATION, AND VALIDATION
    Jansson, P. -E.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1335 - 1344
  • [10] DAISY: MODEL USE, CALIBRATION, AND VALIDATION
    Hansen, S.
    Abrahamsen, P.
    Petersen, C. T.
    Styczen, M.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1315 - 1333